| 1 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 2 | 1 or 2 Module (75mmX75mm) |
| 3 | 4 Module (125mmX75mm) |
| 4 | 6 Moudle (200mmX75mm) |
| 5 | 8 Module (125mmX125mm) |
| 6 | 12 Module (200mmX150mm) |
| 7 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 8 | Group A |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | 5/6 A switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | 15/16 A switch |
| 13 | 6 pin 15/16 A socket outlet |
| 14 | Bell push |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections, painting etc. as required. |
| 17 | Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required. |
| 18 | Supplying and fixing brass batten/ angle holder/PVC holder including connection etc. as required. |
| 19 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 21 | Group A |
| 22 | Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 23 | 20 mm |
| 24 | 25 mm |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 26 | 2X10 sq. mm +1X 6 sq. mm earth wire |
| 27 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 28 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape sizeand CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody including trim . |
| 29 | 18 watt |
| 30 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required |
| 31 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 32 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 33 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) (18-22 watt) |
| 34 | Supplying and fixing following way, single pole and neutral, sheet steel, with MCB distribution board, 240 V,on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 35 | 12 way, Double door |
| 36 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 37 | Single pole |
| 38 | Single pole neutral |
| 39 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 40 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 41 | Upto 35 sq. mm |
| 42 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required |
| 43 | 3x2.5 sq.mm |
| 44 | 3x4 sq.mm |
| 45 | 3x6 sq.mm |
| 46 | Supplying and fixing of street light pole box of size (250 X200X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, Brass screws, washers and 01 no. 10 Amps SP MCB (single pole miniature Circuit breaker), inclusive of making electrical connections, as required at site. |
| 47 | Supply, Installation, testing and commissioning of pre-wired, 35 watt, IP 65, Post top lantern light have symmetric light distribution, 220-240 V, 50 Hz complete i/c all accessories etc. directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips Uniscape Model, Cat No. BGP200 LED45 CW PSU GR CPC SPD or equivalent model of Thorn/Trilux |
| 48 | Supplying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of size 4C x 16 sqmm etc as required. |
| 49 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm. |
| 50 | Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 51 | Supply, Installation, testing and commissioning of pre-wired, wall mounted fancy white light, suitable for installation of LED bulb, 220-240 V, 50 Hz complete i/c all accessories but without bulb etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No. Comet wall fancy light B22 or equivalent model of Thorn/Trilux |
| 52 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 53 | Supply, Installation, testing and commissioning of 10 watt, LED bulkhead pressure die cast housing with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications., 220-240 V, 50 Hz complete including all accessories etc. directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips, Model Endura LED Bulk head, Cat No. WT202W LED10S CW PSU S3 PC or equivalent model of Thorn/Trilux |
| 54 | Supply, Installation,testing and comissioning of 15 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required |
| 55 | Supplying and fixing of 40A/50A/63A, 10 KA rating, double pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make-Hager, Cat.No-NCN240N/NCN250N/NCN263N or equivalent model of Legrand/ABB. |
| 56 | Supplying and fixing DP sheet steel enclosure on surface/ recess complete etc. as required Please Enable Macros to View BoQ information |