| 1 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction (1-2 MISC 2024-25) |
| 2 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3.6 (Hand mixing) (11-4-1-2 MORD 2024-25) |
| 3 | P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 Nominal mix 1:2.5:5 (Hand mixing) (13-11-2 MORD 2024-25) |
| 4 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (For height upto 5 m) R.C.C. grade M 25 (12-5-4 MORD 2024-25) |
| 5 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C M30 Height 5m to 10 m (13-1-2-B MORD 2024-25) |
| 6 | Centering shuttering including strutting, propping etc. and removal of form work FOUNDATION UP TO PLINTH (5.9.1 D.S.R. 2023) |
| 7 | Centering shuttering including strutting, propping etc. and removal of form work COL SUPER STRUCTURE (5.9.6 D.S.R. 2023) |
| 8 | Centering shuttering including strutting, propping etc. and removal of form work Roof Beam (5.9.5 D.S.R. 2023) |
| 9 | Centering shuttering including strutting, propping etc. and removal of form work Slab (5.9.3 D.S.R. 2023) |
| 10 | Reinforcement for R.C.C work including straighting,cutting,bending ,placing in position and bending all complete Thermo-Mechanically Treated bars. (5.22.6 D.S.R. 2023) |
| 11 | Tubular Steel Railing on Precast RCC posts, 1.2 m high above Ground Level Providing, fencing and erecting 50 mm dia painted steel pipe railing in 3 rows on precast M-20 grade RCC vertical posts 175 mm x 175 mm x 1.8 m high (1.2 m above Gl) with 3 holes 50 mm dia for pipe, fixed 2 m centre-to- centre complete as per approved drawings Clause 1706 (10-15 MORD 2024-25) |
| 12 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction (1-4) (1-4 MISC 2024-25) |
| 13 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc.complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction (1-3) (1-3 MISC 2024-25) |
| 14 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (2-2) (2-2 MISC 2024-25) Please Enable Macros to View BoQ information |