| 1 | Demolishing mud phaska in terracing and disposal of material within 50 meters lead |
| 2 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead A) With cement mortar 1:4 (1 cement : 4 fine sand) |
| 3 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 4 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. A) 1 mm thick |
| 5 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work. |
| 6 | Stone tile (polished) work for wall lining over 12mm thick bed of cement mortar 1:3 (1cement : 3 coarse sand) and cement slurry @ 3.3kg/sqm including pointing in whitecement with curing complete.i) Granite of any colour and shade. |
| 7 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: A) W.C. pan with ISI marked white solid plastic seat and lid. |
| 8 | Providing and fixing uplasticized PVC connection pipe with brass unions A)15 mm nominal bore |
| 9 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 10 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :a) Gutter .(600 mm over all girth |
| 11 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.A) 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 13 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs,balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cementadmixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining wallsupto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin- charge.A)With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 14 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75mm deep chase. |
| 15 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron,finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete.A)Size of tile 600x600 mm |
| 17 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 18 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with whitecement and matching pigment etc., complete.A)In colour such as White, Ivory, Grey, Fume Red Brown. |
| 19 | Renewing glass panes, with putty and nails wherever necessary including raking out old putty :A) Float glass panes of thickness 4.0 mm(weight not less than 10kg/sqm) |
| 20 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 21 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead :A) of area of 3 sqm. and below |
| 22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.15.23.1 For thickness of tiles 10 mm to 25 mm |
| 23 | Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonals braces of 40x40x6mm angle iron, 3mm M.S. gusset plates at the junction and corners, 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer, |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.A) With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 25 | Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar1:4 (1 cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar,including providing and mixing water proofing material in mortar @ 1kg per 50 kg of cement , all complete as per direction of Engineer-incharge. |
| 26 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 27 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: A) Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm |
| 28 | Lettering with black Japan paint of approved brand and manufacture. |
| 29 | Labur engaged for shifting of mulba/shifting of desks/ cleaning cleaning of kota stone on stairs/floors etc. |
| 30 | Providing and fixing M.S tubular frames for doors, windows, ventilators and cupboard with rectangular /L-type sections, made of 1.60 mm thick M.S Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.A) Fixing with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of C.C. 1:3:6 (1cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size) . |
| 31 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.A) Fixed to steel windows by welding |
| 32 | Providing and fixing 35mm glazed shutters for doors, windows and clerestory windows using 4mm thick float panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 33 | Second class deodar wood. |
| 34 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : |
| 35 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.A) With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 36 | 15mm Cement plaster on the rough side of single or half brick wall of mix: A)1 : 6 ( 1 cement : 6 fine sand) |
| 37 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:A)1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 39 | Foundations, footings, bases for columns |
| 40 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts,bolts and washers as required complete as per the direction of Engineer-incharge. A)Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade. |
| 41 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 42 | Precast terrazzo tiles 22mm thick with graded marble chips of size upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles,including rubbing, polishing and curing complete with tiles of :Medium shade using 50% white cement and 50% ordinary cement. |
| 43 | Applying priming coat:A) With ready mixed pink or grey primer of approved brandand manufacture on wood work (hard and soft wood) |
| 44 | Carriage of the following materials by Mechanical Transport from source to site of work incl. loading, unloading and stacking complete :- |
| 45 | Sand for an average lead of 5 Km |
| 46 | Stone aggregate below 40mm nominal size for an average lead of 5 Km Please Enable Macros to View BoQ information |