Name of Work:- Shifting of fountain including cable work at Goverdhan Sagar lake, Udaipur
Sl. No.
Item Description
1
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 70 sqmm 3.5 core
2
P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 10.0 Sq.mm 3 core flat / Round
3
4.0 Sq.mm 3 core flat / Round
4
2.5 Sq.mm 3 core flat / Round
5
Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .B class 50mm dia
6
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR 90 mm
7
Shifting of control panel box with Foundation including excavation,repairing in all respect ,installation & commissioning from swarn jayanti park to pannadhay cruise park as per direction of engineer in charge
8
Shifting of fountain including dismelting ancher & New rope & ancher installation Propare way repairing in all respect ,installation & commissioning from swarn jayanti park to pannadhay cruise park as per direction of engineer in charge
9
Shifting of Aereator,set including dismelting ancher & New rope & ancher installation Propare way repairing in all respect ,installation & commissioning from swarn jayanti park to pannadhay cruise park as per direction of engineer in charge Please Enable Macros to View BoQ information