| 1 | Desing, supply, installation, testing and commissioning of LED Luminaries to illuminate sports fields for national level non televise matches, with lux level (vertical & Horizontal) glare level as per national lighting code 2010, maintenance factor > 0.85, uniformity, glare and other parameters as per national lighting code 2010 as amended up to date. The luminaries shall be fixed on High Mast pole with Head frame and shall comply with specification given in tender documents. the product shall comply with EN 62471 for Photo-biological safety. CRI > 70, SDCM < 5, IK08, IP 66, Flicker < 5%, CCT 5700 to 6000, Surge Protection 15 KV, Efficacy > 120 lm/w Input Voltage range 140 to 280 volt, THD < 10%, power factor > 0.95 Ambient temp - 10 to 50 Degree C. The LED shall be compliant with LM80-79 standard with Useful L70 life of 50000 Hrs (Complete LM 80 test report for LED should be submitted for 10000 hrs. of testing) at ambient temperature of more than 85 Deg. The luminaire should comply with all the required IEC and IS standards. LM79 and LM80 reports must be submitted from a NABL accredited laboratory. Luminaire and driver must have BIS certificate and the same must be submitted for records. For Proper Aiming luminaire should have provision for mounting of laser aiming device. (Approved LED makes – Osram, Cree, Nichia, Lumileds and approved driver make - Meanwell, Inventronics, ATCO Electronics, Moso or same make as of luminaries) Sports Light fitting approved makes: Phillips / Lightning Technology/BAJAJ/Wipro/NERI/TransrailNote1: The illumination design (dialux report and design parameters) is to be vetted by institutions like NIT or Engineer in-charge. The illumination level given below are minimum. If the agencies design vetted by the above institutions are superior in design, then same shall be adopted for which nothing extra shall be paid. Note2: The agency should obtain and submit to department 5 years onsite warranty for luminaries from manufacturers.CRICKET GROUND PITCH AVG LUX - 750 LUX OUTFIELD AVG LUX - 500 LUX and Design shall be based on IS:2149:1970, IS:1944(Part V):1981, NLC SP-72:2010, IS:5986, IS:2629, ISO 1461 and other reference code as decided by Engineer-in-charge |
| 2 | SITC of single dome LED AOL with connection of electrical supply 220-240 V power supply suitable connection etc. complete as required.(Approved Makes: Phillips / Lightning Technology/BAJAJ/Wipro/NERI) |
| 3 | CablesSupply and laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper/Al conductor, PVC inner sheathed, overall PVC sheathed stranded and twistedcable in conformity to the technical specification and as per latest IS - codes.Supply and lying 3CX 2.5sqmm unarmoured CU cable |
| 4 | Supply and lying 4CX 25sqmm Armoured AL cable |
| 5 | Supply and lying 3.5CX 70sqmm armoured AL cable |
| 6 | Supply and lying 4CX 6sqmm Armoured AL cable |
| 7 | ConduitStructural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 8 | Termination3CX 2.5sqmm unarmoured CU cable |
| 9 | 4CX 25sqmm Armoured AL cable |
| 10 | 3.5CX 70sqmm armoured AL cable |
| 11 | EarthingSupply and lying of Chemical/Maintenance free Earthing with complete accessories |
| 12 | Providing and fixing 25 mm X 3 mm G.I. strip from earth electrode, as required. |
| 13 | High Mast Fixed TypeDesigning, Supply, Installation, testing & commissioning of 30m Hot dip galvanised, polygonal high masts with fixed head frame/cross arms suitable for mounting up to 23 nos. of LED Flood Light complete with all accessories as per specification. The lights shall be mounted on top surface of each crossarm only. Hanging type mounting of LED lights is to be avoided The height of the mast from base to TOP of head frame shall be 30mtrs. Hight mast OEM should have been NABL certification for high mast structure material or should have a valid certification of ISO 9001. The pole shall include a) foundation bolts of suitable length 75mm dia DWC/PVC/GI- pipe for cable entry b) Supplying, installation, testing and commissioning of control panel for 30 mtr. Mast pole with necessary controlling incoming and outgoing switchgears for motor for lifting and lowering main rider unit, cabling for sports light fittings from sports light fittings to controlling switchgears control, aviation light control complete including connection etc. as required.c) Earthing of structure as per the relevant IS standards Note1: The firm shall provide structural and foundation design ( including SBC tests, wind load and snow load calculation sheet, Structural stablity certificate, foundation design and Anchor bolt design refering to IS 875 part 3 and IS 800), the design shall confirm to structural stability in seismic zone 6, which is to be vetted by institutions like NIT or any approved structural engineer qualified for the job for which nothing extra shall be paid. (Approved Sports Light High mast / Pole makes: BAJAJ / VALMOUNT/ TRANSRAIL/RR Ispat (Consoul)/Utkarsh) |
| 14 | MarinderThe Mast should have comprehensive arrangement of motorised climbing mechanism (man rider) cage unit for accessing the head frame for repair / maintenance purpose with all safety arrangement like free fall arrester / overload protection etc. |
| 15 | Feeder Piller high mastSupplying, installation, testing and commissioning of IP 55 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 3mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, includingfollowing items mentioned below.INCOMER:-1 No. 63A, TPN MCCB (15kA) with thermo magnetic releases and all required accessories.1 Set phase indication lights (R, Y, B) Solid state type (LED)1 No. 0 to 500V, AC, Volt Meter with VSS & control fuses.1 No. 0 to 100A, Ammeter with ASS &CT's. of ratio 100/5A and class-1 accuracy.Auto Manual SwitchBUS BARS:- 100A 4 wire 3 phase 35KA Aluminium bus bars OUT GOINGS:- 1 Nos 32A Four Ploe MCB for Man Rider.2 nos. + 1 Spare 10A SPN MCB - for Aviation Light23 nos. + 2 Spare 10A SPN MCB - for Light fixture. |
| 16 | Main Panelsupply ,Installation, testing and commissioning of IP 55 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The panel should be suitable for Pedestrail mounting type 500mm above ground level with necessary base frame. The panels shall be designed for minimum expected ambient temperature of 52 degree Celsius, 100 percent relative humidity and dusty weather.INCOMER:-1 No. 150A, TPN MCCB (55kA) with thermo magnetic releases and all required accessories.1 Set phase indication lights (R, Y, B) Solid state type (LED)1 No. 0 to 500V, AC, Volt Meter with VSS & control fuses.1 No. 0 to 200A, Ammeter with ASS &CT's. of ratio 200/5A and class-1 accuracy.Outgoing4 Nos. 63A TPN MCCB (15kA) with thermo-magnetic releases. |
| 17 | Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template as per OEM design. |
| 18 | Power Supply partSITC of 200KVA Substation complete in all respects alon with eartning , LT distributio box, cables, Channel iron protection equipment, poles insulators, and all requsite hardware |
| 19 | Supplying & Laying of one number XLPE Insulated and PVC Sheathed aluminium conductor armoured cable of 1.1 KV grade ISI marked conf. to I.S:7098 (Part-I) of following size in the existing RCC/ HUME/ METAL pipe as required.3½ X 185 sq. mm |
| 20 | Supply installation, testing and commissioning of 160 kVA Silent D.G. Set Model (415V/ 50 Hz) Prime rating, ±1% voltage regulation, electric start, H class insulation, turbo charged and after cooled engine, CPCB-IV+ Emission Compliant, Radiator-cooled, coupled with alternator mounted on a common base frame along with following accessories;* DG Set Synchronization Controller* Remote Monitoring Facility* Residential Silencer* Batteries with connecting leads* Aftertreatment* DEF PETU* Inbuilt Fuel Tank with connecting pipes* AVM pads* First fill of Lube Oil & Coolant* Acoustic Enclosureconforming to relevant IS/IEC standards like IS 4722, 13364, 15242, 3043 etc.along witth requsite cables and other hardware and equipment as required at site as directed by site incharge |
| 21 | Supply installation and testing and commissioning of contactor based AMF Panel including battery charer along with auto/manual mode and audio visual annunciation feature, duly fitted with 600 A MCCBs 3 pole 50KA with Adjustable amperage and 200A, 440V, 50kA TPN tinned copper Bus Bar all insulated with provision for tapping all the three phases and neutral in a CRCA sheet steel powder coated IP 54 enclosure conforming to Is/IEC 61439 standards including all carriages complete |
| 22 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 23 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 24 | SEATING TIEREarthwork in excavation by manual means in trenches for foundation drains pipes etc not exceeding 1.5mtr in width and not exceeding 10 sqm on plan depth upto 1.5mtr including backfilling of soil & disposal of excavated soil to be leveled and neatly dressed within 25mts lead. |
| 25 | P/L stone soling hand packed incl ramming with heavy rammers all carriage upto site of work |
| 26 | Providing and laying in position specified grade of cement concrete excluding the cost of centering, shuttering, finishing all work upto plinth level in 1:4:8 (1 cement : 4coarse sand : 8graded stone aggregate 40mm nominal size) |
| 27 | Providing and laying in position specified grade of cement concrete excluding the cost of centering, shuttering, finishing all work upto plinth level in 1:2:4 (1 cement : 2coarse sand : 4graded stone aggregate 20mm nominal size) |
| 28 | Centering & shuttering including strutting, propping etc. and removal of formwork etc Foundations, footings, bases for columns |
| 29 | Steel work welded in built up sections trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required |
| 30 | Painting on steel work with synthetic enamel paint of approved brand and manufactureto give an even shade. Please Enable Macros to View BoQ information |