| 1 | GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ. |
| 2 | PLC replacement at Ratlam |
| 3 | Dual Redundant, hot standby, PLC (microprocessor based) system, fault avoidant, complete with Processor, I/O modules, Serial interface modules, Media Converters, Relay Modules,TBs, MCBs, Data Panel (wherever applicable), interconnecting cables, data cables & Marshalling Panels, rack power supply (dual-redundant), interrogation power supplies (dual-redundant), software auto-manual stations, emergency shutdown switch, diagnostics, firmware, power distribution cabinets, Lightning protection devices and all installation materials etc. so as to make the system complete in all respects as per system configuration, I/O list and tender specifications. |
| 4 | PLC SYSTEM <500 IOs For I/Os upto 500 |
| 5 | SERIAL SPDs For RS 232/485 signals |
| 6 | DI ZB For DI |
| 7 | AO ZB For A/O |
| 8 | LAN SPDs For LAN application |
| 9 | AI/ AO SPDs For Analog signals (AI/AO) |
| 10 | PULSE ZB For Pulse |
| 11 | AI ZB For AI |
| 12 | ZB For RTD |
| 13 | PLC Spare |
| 14 | PLC Processor Module |
| 15 | PLC Processor power supply |
| 16 | NIU / profibus communication card |
| 17 | Rack power supply |
| 18 | Digital input module |
| 19 | Digital output module |
| 20 | Analog input module |
| 21 | Analog output module |
| 22 | Serial Interface communication module |
| 23 | Field interrogation power supply |
| 24 | Control System |
| 25 | Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications |
| 26 | Supply of 23\\" Display Monitor as per tender specifications. |
| 27 | PLC programming / Ladder logic software etc. for Dual redundant PLC's/ PLC test jigs |
| 28 | MMI Software of same make as the PLC (including one time license fee ) etc as per the tender specification, for the following for running of the station in emergency situations like failure of SCADA computers. It includes Operating System and antivirus software for each Virtual machine : 1 Set shall comprise software for SCC Server cum workstations (02 nos) and for programming terminal (1 no) with feature of editing/Creating new graphic screens |
| 29 | LED Display Unit (50\\" & above) System with interface complete with all inter connecting cables, cords, connectors, peripherals, OEM's make Mounting Kits etc complete in all respects as per the tender specifications & datasheet. |
| 30 | Industrial Grade Ethernet to 2-4 port Serial Gateway/ MODBUS TCP to MODBUS RTU Converter with required connectors, cables, power supply etc. as per tender specifications. (1 set comprises 2 converters) |
| 31 | LaserJet Printer, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per tender specs & datasheet |
| 32 | Supply of CAT6 cable (unarmoured) as per tender specifications |
| 33 | Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications. |
| 34 | Service |
| 35 | Supervison, erection, testing & commissioning of PLC at attended / unmanned stations, erection and commissioning of PLC, Instruments at Station/ Unmanned locations including termination of control cables, installation and commissiong of SCC systems, interfacing & integration of PLC with SCC machines and field instrumentation systems including supplied hardware/ software with station on remote & auto including development of control logics etc making all jobs complete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, services rendered etc. For Station Location upto 1000 IOs |
| 36 | Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc. at SCCs |
| 37 | Interfacing of additional RTUs (manned/Unmanned) with SCADA System, Modifications in SCADA/Historian/Webserver including adding the RTU to SCADA System, creation and configuration of Tags in SCADA systems/Historian/Webserver and modification in graphics screens of SCADA Clients and Webserver, testing of control using SCADA System etc. complete in all respects as per the directions of EIC. (1 Set= Per RTU location) |
| 38 | Submission of As Built Documentation |
| 39 | DISMATLING OF existing PLC/CONTROL PANEL / MIMIC PANEL/ CONSOLE DESK/UPS/RTU: Dismantling of existing PLC / Control panels / MIMIC panels/UPS/RTU etc, retrieving cards/ modules in good condition and storage as per direction of site engineer/EIC, retrieving cables from control panels in healthy condition, isolating the retreived cables, labelling, of the cables etc so as to complete the job in every respect as per directions of site engineer / EIC |
| 40 | PLC replacement at Hazira |
| 41 | PLC System |
| 42 | PLC SYSTEM <500 IOs For I/Os upto 500 |
| 43 | SERIAL SPDs For RS 232/485 signals |
| 44 | DI ZB For DI |
| 45 | AO ZB For A/O |
| 46 | LAN SPDs For LAN application |
| 47 | AI/ AO SPDs For Analog signals (AI/AO) |
| 48 | PULSE ZB For Pulse |
| 49 | AI ZB For AI |
| 50 | ZB For RTD |
| 51 | PLC Spare |
| 52 | PLC Processor Module |
| 53 | PLC Processor power supply |
| 54 | NIU / profibus communication card |
| 55 | Rack power supply |
| 56 | Digital input module |
| 57 | Digital output module |
| 58 | Analog input module |
| 59 | Analog output module |
| 60 | Serial Interface communication module |
| 61 | Field interrogation power supply |
| 62 | Control System |
| 63 | Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications |
| 64 | Supply of 23\\" Display Monitor as per tender specifications. |
| 65 | PLC programming / Ladder logic software etc. for Dual redundant PLC's/ PLC test jigs |
| 66 | MMI Software of same make as the PLC (including one time license fee ) etc as per the tender specification, for the following for running of the station in emergency situations like failure of SCADA computers. It includes Operating System and antivirus software for each Virtual machine : 1 Set shall comprise software for SCC Server cum workstations (02 nos) and for programming terminal (1 no) with feature of editing/Creating new graphic screens |
| 67 | LED Display Unit (50\\" & above) System with interface complete with all inter connecting cables, cords, connectors, peripherals, OEM's make Mounting Kits etc complete in all respects as per the tender specifications & datasheet. |
| 68 | Industrial Grade Ethernet to 2-4 port Serial Gateway/ MODBUS TCP to MODBUS RTU Converter with required connectors, cables, power supply etc. as per tender specifications. (1 set comprises 2 converters) |
| 69 | LaserJet Printer, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per tender specs & datasheet |
| 70 | Supply of CAT6 cable (unarmoured) as per tender specifications |
| 71 | Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications. |
| 72 | Service |
| 73 | Supervison, erection, testing & commissioning of PLC at attended / unmanned stations, erection and commissioning of PLC, Instruments at Station/ Unmanned locations including termination of control cables, installation and commissiong of SCC systems, interfacing & integration of PLC with SCC machines and field instrumentation systems including supplied hardware/ software with station on remote & auto including development of control logics etc making all jobs complete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, services rendered etc. For Station Location upto 1000 IOs |
| 74 | Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc. at SCCs |
| 75 | Interfacing of additional RTUs (manned/Unmanned) with SCADA System, Modifications in SCADA/Historian/Webserver including adding the RTU to SCADA System, creation and configuration of Tags in SCADA systems/Historian/Webserver and modification in graphics screens of SCADA Clients and Webserver, testing of control using SCADA System etc. complete in all respects as per the directions of EIC. (1 Set= Per RTU location) |
| 76 | Submission of As Built Documentation |
| 77 | DISMATLING OF existing PLC/CONTROL PANEL / MIMIC PANEL/ CONSOLE DESK/UPS/RTU: Dismantling of existing PLC / Control panels / MIMIC panels/UPS/RTU etc, retrieving cards/ modules in good condition and storage as per direction of site engineer/EIC, retrieving cables from control panels in healthy condition, isolating the retreived cables, labelling, of the cables etc so as to complete the job in every respect as per directions of site engineer / EIC |
| 78 | CAMC for Ratlam |
| 79 | AMC charges for 1st year |
| 80 | AMC charges for 2nd year |
| 81 | AMC charges for 3rd year |
| 82 | AMC charges for 4th year |
| 83 | AMC charges for 5th year |
| 84 | CAMC for Hazira |
| 85 | AMC charges for 1st year |
| 86 | AMC charges for 2nd year |
| 87 | AMC charges for 3rd year |
| 88 | AMC charges for 4th year |
| 89 | AMC charges for 5th year Please Enable Macros to View BoQ information |