| 1 | Taking up or down unserviciable / old GI tubing any grade and fittings connections ( including dewatering of trench) and removal from site all as directed by Engr-in-charge. |
| 2 | 15mm dia bore |
| 3 | 20 mm dia bore |
| 4 | 25mm dia bore |
| 5 | 40mm-to-80mm dia bore |
| 6 | Refixing / Relaying old steel tubing and connections in new or old position (Walls, ceiling, floors,trenches etc. all as directed by Engr-in-charge. |
| 7 | 15 mm dia bore |
| 8 | 20 mm dia bore |
| 9 | 25mm dia bore |
| 10 | 40mm to 50mmdia bore |
| 11 | Supply & lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches all as specified of following sizes :- |
| 12 | 15mm dia bore |
| 13 | 20 mm dia bore |
| 14 | 25mm dia bore |
| 15 | 40mm dia bore |
| 16 | 50mm dia bore |
| 17 | 80mm dia bore |
| 18 | Taking up cast iron water mains with fittings ( including dewatering of trench) with spigot and socket ends and lead joint including burning out joints and recovering lead. |
| 19 | 100 mm bore |
| 20 | 150 mm bore |
| 21 | 200 mm bore |
| 22 | 250 mm bore |
| 23 | 300 mm bore |
| 24 | Caulking existing leaking lead joint including jointing materials such as lead, lead wool, spurn yarn for the following sizes of CI pipe lines complete all as directed. |
| 25 | 80 mm bore |
| 26 | 100 mm bore |
| 27 | 150 mm bore |
| 28 | 200 mm bore |
| 29 | 250 mm bore |
| 30 | 300 mm bore |
| 31 | M & L bends (any type, radius and angle) tapers any type (straight bend, increasing, decreasing or double socked etc) tee pieces , single branch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe upto 150 mm bore. |
| 32 | M & L bends (any type, radius and angle) tapers any type (straight bend, increasing, decreasing or double socked etc) tee pieces , single branch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe 200 mm to 300 mm bore. |
| 33 | Taking down and S&F PVC Float valves , high pressure ,with polythene float and flynut complete ,screwed for iron pipe of size: |
| 34 | a)15 mm dia |
| 35 | a)20 mm dia |
| 36 | b) 25 mm dia |
| 37 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil for cleaning surface area and cutting shurbes/grass & bushes and remove the material at various installation at site. all as directed by Engr-in-charge. |
| 38 | Taking down unserviceable gun metal gate valves including S & F gun metal gate valves with iron wheel head screwed both end for iron pipe and fixed. |
| 39 | 20mm dia bore |
| 40 | 25mm dia bore |
| 41 | 40mm dia bore |
| 42 | 50mm dia bore |
| 43 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of GI tubing / taking out of GI tubing and getting out in :- |
| 44 | a) Soft /loose soil |
| 45 | b) Hard / dense soil |
| 46 | c) Soft disintegrated soil |
| 47 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, asdirected by Engineer-incharge |
| 48 | Returning filling in including spreading levelling, watering and well ramming in layers n. exc 25cm with soil obtained from excavation. |
| 49 | Removing excavated soil / material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point. |
| 50 | Demolishing or dismantling Concrete in ground floors and pavings n exc 15 cm thickness |
| 51 | Material & Labour for Cement concrete in foundations, filling and mass concrete(1:2:4) |
| 52 | Supply fabricating and fixing MS sheet, as in chamber cover including heavy duty hinges,with locking arrangments welding bending cold or hot drilling holes for bolts of any shape and sizes frames of angle or other section and hold fast arrangements made by MS flat iron,etc all as as directed by engr in charge |
| 53 | M & L for taking out unserviceable butterfly valve and replace with new butterfly valve of same dia including all nuts and bolts of following sizes:- |
| 54 | 80 mm dia size |
| 55 | 100 mm dia size |
| 56 | 150 mm dia size |
| 57 | 200 mm dia size |
| 58 | M&L for Construction of brick masonry valve pit inside measurement 1.2 m x 1.2 m x 90 cm in replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm) as per existing size including locking arrangement suitable for sluice valve 200 mm to 300mm and sheet cover with one coat of red oxide and two coat of Synthetic enamel paint and complete leveling refilling the unwanted existing trenches ,as per ground requirement including demolition of existing/old valve chamber all as per direction by Engineer in charge. |
| 59 | M&L for Construction of brick masonry valve pit inside measurement 0.90m x 0.90m x 0.90m in replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm) as per existing size including locking arrangement suitable for sluice valve 80 mm to 150 mm and sheet cover with one coat of red oxide and two coat of Synthetic enamel paint and complete leveling refilling the unwanted existing trenches ,as per ground requirement all as directed by Engr in charge |
| 60 | M & L for Mechanical Joint clamp of (minimum thickness of 6mm) type,flap type,GP joint, Mundi Type for CI,DI Pipe of size 80mm along with MS nut bolt washer |
| 61 | M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundi type for CI,DI Pipe of size 100mm along with MS nut bolt washer |
| 62 | M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundi type for CI,DI Pipe of size 150mm along with MS nut bolt washer |
| 63 | M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundi type for CI,DI Pipe of size 200mm along with MS nut bolt washer |
| 64 | M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint for CI,DI Pipe of size 250mm along with MS nut bolt washer |
| 65 | M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundi Type for CI,DI Pipe of size 300mm along with MS nut bolt washer |
| 66 | M & L DI water pipes with spigot and socket ends including rubber gasket joint Class K 7, in any length, laid in trenches. |
| 67 | 100 mm bore |
| 68 | 150 mm bore |
| 69 | 200 mm bore |
| 70 | 250 mm bore |
| 71 | 300 mm bore |
| 72 | Taking out and S&F unserviceable CI sluice valve from exisiting position by opening the nuts , bolts and breaking of valve chamber including necessary earth work and excvation in any type of soil and S & F CI sluice valve with PN rating 1:6 conforming to IS 14846 duly ISI marked with iron wheel head HSS spindle and all other conected accessories such as gland packing, bolts, and nuts rubber gasket etc complete and making good the vlave chamber to match with the adjacent surface including brick / PCC block works, plastering etc for the following sizes complete all as directed . |
| 73 | 80 mm bore |
| 74 | 100 mm bore |
| 75 | 150 mm bore |
| 76 | 200 mm bore |
| 77 | 250 mm bore |
| 78 | 300 mm bore |
| 79 | Taking out water sample in clean container gettng the same tested from the Deptt of Water and waste water examiner, Institute of Preventive medicine for chemical and bacteriological test complete all as directed by Engr -in-Charge. |
| 80 | Taking down old LT panel and Supply install, test and commissioning of Powder coated LT panel cubical Outdoor type double door, free standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomer ACB/MCCB and outgoing feeders with MCCB/MCB. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The cubicle shall have free standing bottom frame/stand of height 600mm & dimension as required for panel & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 Tank Process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including taking down of old unsv panel after disconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation and making good as per existing, complete all as specified & directed by Engineer in Charge. |
| 81 | with the following acessories(a) S& F MCCB TPN,250 Amp - 01 No. (Mains), MCCB TP,100 Amp - 02 No. (AIr Blower), MCB TP,63 Amp - 02 No. (Raw Sewage Feed), MCB TP,32 Amp - 02 No. (Filter Feed),MCB TP,16 Amp - 02 No. (Clear Water).(b) Fully automatic star delta starter suitable for comprising MNX contactor, with add on block,timer,overload relay(28-42 Amps) ,having Auto manual switch and 2 way selector switch with control wiring Suitable for Motor (Air Blower) of capapcity 40 HP- 02 Set(c) Fully automatic Star Delta Starter comprising MNX contactor, with add on block,timer,overload relay(9-14 Amps), having Auto manual switch and 2 way Motor setector switch with control wiring suitable for motor (Raw Sewage Feed Pump)) of capacity of 12.5 HP -02 Set (c) Fully automatic Star Delta Starter comprising MNX contactor, with add on block,timer,overload relay (6-10 Amps), having Auto manual switch and 2 way Motor setector switch with control wiring suitable for motor (Filter Feed) of capacity of 10 HP -02 Set(d) Fully automatic DOL starter comprising MNX contactor with add on block,timer,overload relay (2.5-4 Amps),having Auto manual switch and 2 way Motor setector switch with control wiring suitable for motor(Clear Water) of capacity 03 HP - 02 Sets(e) MCB TP of 16 Amps and 20 Amps - 04 Nos,MCB TP of 40 Amps - 01 Nos,MCB SPN of 10 Amps - 01 Nos,MCB SP of 06 Amps- 03 Nos, MCB TP of 63 Amps - 02 Nos.(f) On/OFF push button for Air compressor,clean water pump,filter feed pump,filter press pump,raw sewage,air blower.(g) Red/Green indicator for Air compressure,clean water pump,filter feed pump,filter press pump,raw sewage,air blower. (f) Digital Voltmeter, Ampere meter with CT and selector switch. Notes :- (1) Panel design need to be approved by engineer in charge.(2) All accesories need at site deemed to be included in Item quoted. |
| 82 | Taking down old LT panel and Supply install, test and commissioning of Powder coated LT panel cubical Indoor type floor standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 2 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomer and outgoing feeders . The TPN 3bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The cubicle shall have floor standing bottom frame & of height 600mm & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 2 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 tank process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including taking down of old unsv panel after disconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation and making good as per existing, complete all as specified & directed by Engineer in Charge. |
| 83 | with the following acessories(a) S& F MCCB TPN,250 Amp - 01 No. (Mains), MCCB TP,100 Amp - 02 No. (AIr Blower), MCB TP,63 Amp - 02 No. (Raw Sewage Feed), MCB TP,32 Amp - 02 No. (Filter Feed),MCB TP,16 Amp - 02 No. (Clear Water).(b) Fully automatic star delta starter suitable for comprising MNX contactor, with add on block,timer,overload relay(28-42 Amps) ,having Auto manual switch and 2 way selector switch with control wiring Suitable for Motor (Air Blower) of capapcity 40 HP- 02 Set(c) Fully automatic Star Delta Starter comprising MNX contactor, with add on block,timer,overload relay(9-14 Amps), having Auto manual switch and 2 way Motor setector switch with control wiring suitable for motor (Raw Sewage Feed Pump)) of capacity of 12.5 HP -02 Set (c) Fully automatic Star Delta Starter comprising MNX contactor, with add on block,timer,overload relay (6-10 Amps), having Auto manual switch and 2 way Motor setector switch with control wiring suitable for motor (Filter Feed) of capacity of 10 HP -02 Set(d) Fully automatic DOL starter comprising MNX contactor with add on block,timer,overload relay (2.5-4 Amps),having Auto manual switch and 2 way Motor setector switch with control wiring suitable for motor(Clear Water) of capacity 03 HP - 02 Sets(e) MCB TP of 16 Amps and 20 Amps - 04 Nos,MCB TP of 40 Amps - 01 Nos,MCB SPN of 10 Amps - 01 Nos,MCB SP of 06 Amps- 03 Nos, MCB TP of 63 Amps - 02 Nos.(f) On/OFF push button for Air compressor,clean water pump,filter feed pump,filter press pump,raw sewage,air blower.(g) Red/Green indicator for Air compressure,clean water pump,filter feed pump,filter press pump,raw sewage,air blower. (f) Digital Voltmeter, Ampere meter with CT and selector switch. Notes :- (1) Panel design need to be approved by engineer in charge.(2) All accesories need at site deemed to be included in Item quoted. |
| 84 | Taking down old LT panel and Supply install, test and commissioning of Powder coated LT panel cubical Outdoor type double door, free standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomer ACB/MCCB and outgoing feeders with MCCB/MCB. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The cubicle shall have free standing bottom frame/stand of height 600mm & dimension as required for panel & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 Tank Process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including taking down of old unsv panel after disconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation and making good as per existing, |
| 85 | with the following acessories(a) S& F MCCB TPN,200 Amp - 01 No. (Mains).(b) Fully automatic star delta starter suitable for comprising MNX 32 contactor, with add on block,timer,overload relay (14 Amp-23 Amp) ,having Auto manual switch and 2 way Motor setector switch with control wiring - 02 Nos (c) Fully automatic DOL starter comprising MNX 16 contactor, with add on block,timer,overload relay (06 Amp-10 Amp) ,having Auto manual switch and 2 way Motor setector switch with control wiring -02 Nos(d) Fully automatic DOL starter comprising MNX 09 contactor with add on block,timer,overload relay (4.5 Amp-7.5 Amp) ,having Auto manual switch and 2 way Motor setector switch with control wiring -02 nos(d) Fully automatic DOL starter comprising MNX 09 contactor with add on block,timer,overload relay (4.5 Amp-7.5 Amp) ,having Auto manual switch and 2 way Motor setector switch with control wiring -02 nos(e) MCB TP of 16 Amps and 20 Amps - 04 Nos,MCB TP of 40 Amps - 01 Nos,MCB SPN of 10 Amps - 01 Nos,MCB SP of 06 Amps- 03 Nos, MCB TP of 63 Amps - 02 Nos.(f) On/OFF push button for Air compressor,clean water pump,filter feed pump,filter press pump,raw sewage,air blower.(g) Red/Green indicator for Air compressure,clean water pump,filter feed pump,filter press pump,raw sewage,air blower. (f) Digital Voltmeter, Ampere meter with CT and selector switch. Notes :- (1) Panel design need to be approved by engineer in charge.(2) All accesories need at site deemed to be included in Item quoted. |
| 86 | Repairing of leakages/blockage GI pipeline of size 15 mm,20mm,25mm by replacing the Tees, bends, sockets,unions,nipple, pipeline of length upto 2 meter and providing the other materials required to complete the job including material, excavation and earth work complete all as per the direction of engr in charge.Note: (i) Required length exceeding 2 meters will be measured under respective item(ii) Daily Team should be detailed to attend complaints regularly(iii) Should rectify the fault within 24 hrs(iv) Should make necessary arrangements and liasion to work in civil area |
| 87 | Repairing of leakages/blockage GI pipeline of size 40mm,50mm by replacing the Tees, bends, sockets,unions,nipple, pipeline of length upto 2 meter and providing the other materials required to complete the job including material, excavation and earth work complete all as per the direction of engr in charge.(i) Required length exceeding 2 meters will be measured under respective item(ii) Daily Team should be detailed to attend complaints regularly(iii) Should rectify the fault within 24 hrs(iv) Should make necessary arrangements and liasion to work in civil area |
| 88 | Repairing of leakages/blockage GI/DI pipeline of size 80mm -150mm by replacing the Tees, bends, sockets,unions,nipple, and providing the other materials required to complete the job including material, excavation and earth work complete all as per the direction of engr in charge.(ii) Daily Team should be detailed to attend complaints regularly(iii) Should rectify the fault within 24 hrs(iv) Should make necessary arrangements and liasion to work in civil area |
| 89 | Repairing of leakages/blockage CI/DI pipeline of size 150mm-300mm by replacing the Tees, bends, sockets,unions,nipple, and providing the other materials required to complete the job including material, excavation and earth work complete all as per the direction of engr in charge.(ii) Daily Team should be detailed to attend complaints regularly(iii) Should rectify the fault within 24 hrs(iv) Should make necessary arrangements and liasion to work in civil area |
| 90 | Supply & Fixing Bib taps,stainless steel crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed Please Enable Macros to View BoQ information |