|
| 1 | M & L for servicing of high mast light driving mechanism by checking alll electrical and mechnical component, chain, pully, rope,. Motor etc and greasing oiling of chain, motor, pully etc servicing of motor, control panel, auxiliary contacts, replacement of u/s items i.e. toggle switch, indicator light, control wiring complete all as specified and directed. |
| 2 | Labour & Tools incl ladders to attending general street light complaints for repair / maint of street light/ flood light fitting any type and capacity after taking out from poles upto 11 mtrs height any place wihin the stn checking throughly function of drivers and connected item, removing carbon on joints, repairing of cable joints/ loose connection, making sholdering etc incl replacement of small parts like wire upto 1.5 mtr long, nut bolts, screws , insulation tape etc fixing on pole after carry out nacessary repairs and testing for smooth functioning complete all as specified and directed. Note : (a) Repairs may be carryed out as an when required basis on site i.e number of times and shall be measured and paid as per site requirement as per satisfaction of Engr-in-Charge and Spare parts like electronic drivers, ballast , lamp , ignator etc shall be measured and paid separately in respective items. |
| 3 | Lowering down of high mast light at any height repairing and replacement of unserviceable parts such as electronic driver, surge protector and internal and external circuit etc as required on site complete all as specified and directed. (Note : Spare / parts required for replacement shall be measured and paid seperately and lowering down work may be carry out as and when required basis for any kind of repair.) |
| 4 | Taking down the existing street light fitting and Supply & fix (in Repalcement) energy saving and environmental frindly long life LED Street light fitting 45 Watt 230 V AC THD<10%, CRI > 80%, Lumen efficacy not less then 110 Lm per watt outdoor type with high pressure die cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics IP 65/IP66 road way luminaries with LEDs as light source and lens embedded, toughened glass cover and impact resistance of IK07 and electronic driver with 10 KA Surge protector fixed on pole on existing bracket including connection complete all as specified and directed. |
| 5 | -ditto- all as per item Ser No 4.00 above but 60 Watt complete all as specified and directed |
| 6 | -ditto- all as per item Ser No 4.00 above but 90 Watt complete all as specified and directed |
| 7 | Taking down the existing Flood lights fitting and Supply & fix (in Repalcement) energy saving and environmental frindly long life exclusive innovative flood light luminaries 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with LEDs as light source and lens embedded on each LED, toughened glass cover and impact resistance of IK07 and electronic driver fixed on high mast pole or any any other place as requird on site incl making all nacessary arrangement for fixing complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers complete all as specified and directed. |
| 8 | -ditto- all as per item Ser No 7.00 above but 120 Watt complete all as specified and directed |
| 9 | -ditto- all as per item Ser No 7.00 above but 200/210 Watt complete all as specified and directed |
| 10 | Taking down old,rusted, unsv Junction box of any size, type and supply & fix new junction box of size not less than 210 mm x190 mm x 110 mm, made out of Fibre material, shockproof and rustproof, cable entry from bottom. 100% wheather proof and fixing to pole etc using suitable GI clamps of size 25x3mm, nuts, bolts etc for accommodating and including the following complete all as specified and directed:-a) TPN Connector 32 A b) MCB SP 6A-01 Nos |
| 11 | S&F in replacement of PVC insulated 1.5 sqmm copper three core conductor cable between cable loops box to fitting drawn through the pole complete all as specified and directed |
| 12 | S&F along pole PVC non metallic conduit of dia 20 mm medium grade including MS clamps and nut bolts etc for fixing along the pole complete all as specified and directed |
| 13 | Taking out the old unsv pole ,Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with black bituminous paint for embedded portion of pole complete all as specified and directed |
| 14 | Excavation in trenches not exc 1.5 m wide and exc 1.5 m in depth and getting it out for laying of cable / pole etc in following soil starta complete all as specified and directed |
| 15 | Soft/loose soil |
| 16 | Hard/dense soil |
| 17 | Soft/ disintegrated rock |
| 18 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed |
| 19 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed |
| 20 | Supply and laying HDPE DWC pipe 32 mm inner dia SN8 along with coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. |
| 21 | Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified and directed |
| 22 | Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site complete all as specified and directed (Excavation and earth work will be measured seperately) |
| 23 | Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete cable complete all as specified and directed , for following size:- |
| 24 | 25 Sqmm 3.5 core |
| 25 | 16 Sqm 4 core |
| 26 | 10 Sqm 4 core |
| 27 | 10 Sqm 2 core |
| 28 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core multistranded cable flat or circulas 4 sqmm incl taking out old unserviceable wire complete all as specified and directed. |
| 29 | -ditto- all as per item Ser No 23.00 above but Service wire of size 6 Sq mm twin core |
| 30 | -ditto- all as per item Ser No 23.00 above but Service wire of size 10 Sq mm twin core |
| 31 | M&L for scrapping of old aluminium paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces and painting with two coats of aluminium paint on pole , brackets old junction boxes channels etc incl alternate 30 cm wide white and blue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed. |
| 32 | M&L for scrapping old painted surface with emery paper for preparation of smooth surfaces and spray painting with two coats of synthetic enamel paint (as existing on site) for LT/HT Panel/ fidder pillers boxes etc including welding of broken door hinges etc complete all as specified and directed. |
| 33 | Material and labour for Surface excavation n.exc (not exceeding) 30 cm deep and getting out removing of grass and vegetation grown for site clearance around the electrical installations like transformers, LT panels, 2 pole structure, HT panels area inside the fencing complete all as specified and directed. |
| 34 | Trimming for branches of trees, bushes, hurbs under over head line including removal of trees branches INCL CREEPERS etc to a distance not exceeding 5 mtr from over head line complete all as specified and directed.(Note: one span shall be considered as pole to pole distance between two poles) |
| 35 | Provn of services for finding cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and directed. |
| 36 | Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below complete all as specified and directed for following size of joints :- |
| 37 | 25 to 50 sqmm 3.5 core |
| 38 | 70 to 120 sqmm 3.5 core |
| 39 | Supply and fixing LED Post top fitting 40 Watt 5700 K CCT IP 65 powder coated aluminium die cast and spun aluminium with clear diffuser suitable for landscape lighting incl making necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed. |
| 40 | Supply only LED outdoor driver with all Electricals connection as per existing make on site and testing for smooth functioning complete all as specified and directed. For following wattege of existing light fitting |
| 41 | (a) for LED Light fitting 25 to 45 watt |
| 42 | (a) for LED light fitting 60-72 Watts |
| 43 | (b) for LED light fitting 80-120 Watts |
| 44 | (c) for LED light fitting 150 Watt |
| 45 | (d) for LED light fitting 250 Watt |
| 46 | (e ) for LED light fitting 300 Watt |
| 47 | Supply and fixing LED Bollard light fitting 8W IP 65 powder coated PDC aluminium body with opal diffuser weather proof 900 mm long suitable for landscape lighting incl making necessary arrangement for mounting fitting incl PCC work as reqd on site and testing complete all as specified and directed. |
| 48 | Taking down the existing highbay light fitting and Supply & fix (in Repalcement) energy saving and environmental friendly robost IP 66 protected LED midbay with PDC housing and Lens fixed on each LED for better spread of light suitable for ceiling (Surface/Suspended) mount 120 Watt with system efficiency not less than 120 lm/W incl electronic driver with surge protection fixed in ceiling/ suspended incl making all nacessary arrangement for fixing/hanging and anchering as required on site making electrical connections complete all as specified and directed. Contractor shall submit LM 79 report with sample approval. |
| 49 | Supply and fix in repair / replacement of MCCB TP 63 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning complete all as specified and directed. |
| 50 | Taking out carefully serviceable LT UG Cable/wires after disconnecting from DBs on wall/duct/cutting of walls of assorted size as required on site and re routing properly by making proper cutting in wall/cable duct clamping etc completed and making good disturbed surface of wall/floor as existing sourrounding complete all as specified and directed. |
| 51 | Supply and fix MCB SP 6 to 20 Amp Amp, 230 volt 'B' series complete all as specified and directed. |
| 52 | Supply and fix MCB SPN 40 Amp, 230 volt 'B' series complete all as specified and directed. |
| 53 | S&F in replacement of old unserviceable contactor ML-3, 40 Amps power operating voltage 415 V AC Capacity. complete all as specified and directed |
| 54 | M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole foundation or as per site reuirement at electical installations complete all as specified and directed |
| 55 | M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles or as per site reuirement at electical installations complete all as specified and directed incl necessary form work using 20 mm graded stone aggregate etc |
| 56 | Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to and including galvanised iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate no. 3 of SSR part I, and testing on completion including excavation and earth work in any type of soil, PCC 1:3:6 type C1 earthing chamber, precast slab 50 mm thick in cement concrete 1:2:4 type B1 reinforced with welded steel wire fabric (XPM) weight not less than 4kg/sqm, funnel with wire mesh, watering pipe of 20 mm bore medium grade GI pipe and lugs, earthing wire protected by galvanised iron or steel pipe 15 mm dia medium grade 7.5 metre long complete all as specified and as directed. |
| 57 | Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified. |
| 58 | Supply and fixing in repair Street light bracket made out of 40mm dia GI tubing medium grade made to shape 1.5 Mtr long with fixing arrangement for LED fitting duly painted with two coats of synthetic aluminium paint over a coat of primer including MS clamps 25x4mm and back plates fabricated from steel section including nuts, bolts, washer etc complete all as specified and directed by Engineer-in-charge. |
| 59 | M&L for fixing in repairs for 24 Hrs 240V FM1 Quartz type daily timer for controlling street lights contactor complete all as specified and directed by Engr-In- Charge. |
| 60 | Supply and fixing of Indicator lamp Red, yellow, blue in colour LED type for LT Panel/ Street light timer panel complete all as specified and directed |
| 61 | Supply and fixing of TPN 40 amp connector for LT Panel/ Street light timer panel complete all as specified and directed |
| 62 | Supply and fix MCB TPN 415 V, 32 Amps 10 KA B Curve in any specified location complete all as directed at site. |
| 63 | Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site all as directed.( Excavation and earth work will be measured seperately) |
| 64 | M&L for scrapping of old alum paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces and painting with two coats of alum paint on pole , brackets old junction boxes channels etc incl alternate 30 cm wide white and blue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed by Engr -in-Charge. |
| 65 | Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coat of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete as specified. |
| 66 | Supply & fix line separator suitable for LT OH line of 3 phase and neutral conductor complete as specified and directed by Engineer-in-Charge. |
| 67 | All as above item no 53 but single phase and neutral conductor. Please Enable Macros to View BoQ information |
| 68 | All as above item no 53 but single phase and neutral conductor. Please Enable Macros to View BoQ information |