| 1 | Excavation in trenches in hard/dense soil n.exc 1.5 mtr wide and n.exc 1.5 mtr deep & getting out soil for taking out/laying of cables etc.complete all as specified & directed by Engr-in-Charge. |
| 2 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm.complete all as specified & directed by Engr-in-Charge. |
| 3 | Removing excavated mateials n.exc 50 mtr & depositing where directed at a level n.exc 1.5 mtr above the starting point.complete all as specified & directed by Engr-in-Charge. |
| 4 | Supply and laying new dry river sand laid in trenches 8 cm below the cable and 15 cm above the cable and punned to 18 cm as cable cushioning and cover complete all as specified and as directed. |
| 5 | Supply and laying of brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicular to the length of cable, complete all as specified and directed by Engr-in-Charge. |
| 6 | M & L for HDPE conduit of size 32 mm for laying cables in road crossings/drain crossings including necessary clamps/other accessories for laying the conduit along/across the drain, complete all as specified & directed by Engr-in-charge. |
| 7 | M & L for HDPE conduit of size 40 mm for laying cables in road crossings/drain crossings including necessary clamps/other accessories for laying the conduit along/across the drain, complete all as specified & directed by Engr-in-charge. |
| 8 | M & L for HDPE conduit of size 50 mm for laying cables in road crossings/drain crossings including necessary clamps/other accessories for laying the conduit along/across the drain, complete all as specified & directed by Engr-in-charge. |
| 9 | M & L for HDPE conduit of size 100 mm for laying cables in road crossings/drain crossings including necessary clamps/other accessories for laying the conduit along/across the drain, complete all as specified & directed by Engr-in-charge. |
| 10 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 4 core as per IS 7098 incl. lugs/nut-bolts /clamp to mount on walls/ ceiling/floors/ flexible conduit/other accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 11 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm, 3.5 core as per IS 7098 incl. lugs/nut-bolts/clamps to mount on walls/ ceiling/floors/flexible conduit/other accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 12 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm, 3.5 core as per IS 7098 incl. lugs/nut-bolts/clamps to mount on walls/ ceiling/floors//flexible conduit/other accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 13 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm, 3.5 core as per IS 7098 incl. lugs/nut-bolts/clamps to mount on walls/ ceiling/floors//flexible conduit/other accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 14 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm, 3.5 core as per IS 7098 incl. lugs/clamps to mount on walls/ ceiling/floors//flexible conduit/other accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 15 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sqmm, 3.5 core as per IS 7098 incl. lugs/nut-bolts/clamps to mount on walls/ ceiling/floors//flexible conduit/other accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 16 | Supply, Installation, Testing & Commissioning of outdoor type LT Distribution Panel 415 V, 3-ph, 50 Hz capacity, CPRI approved, made out of CRCA sheet 3.15 mm thick outdoor pedestal type, powder coated after 7 tank process polyster siemens gray structural RAL-7032 shade, totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather-dust-verminproof and waterproof having copper busbars of capacity 800 A for R,Y,B and Neutral supported on epoxy type insulator with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables, detachable gland plate at bottom for cable entry/exit, all openings to be covered with rubber gasket, with 40 x 40 x 6 mm angle legs of length not less than 45 cm above ground fixed to necessary PCC 1:3:6 foundation on ground comprising the following:-Incoming(a) MCCB 630A, 4P, 415 V, 50 Hz with rupturing capacity of 36 KA (Thermal Magnetic Release + Both End Spreader Links)-01 No. Make:L&T/ Havells/ Schneider/C&S electric(b) LED Indicating lamps - 03 Nos. Make: C&S/Neptune/L&T/Vaisnavo(c) Digital Three Phase VIF Meter with VLN, VLL, I1, I2, I3, F measurement -01 No. Make: L&T, Schneider, C&S electric(d) CT-630/5A-03 Nos. |
| 17 | Outgoing(a) MCCB 160A, 4P, 415 V, 50 Hz with rupturing capacity of 25 KA(Thermal Magnetic Release +Both End Spreader Links)-03 Nos. (02 for Load & 01 spare) Make:L&T/ Havells/ Schneider/C&S electric(b) MCCB 63A, 4P, 415 V, 50 Hz with rupturing capacity of 25 KA(Thermal Magnetic Release + Both End Spreader Links)-01 No. Make:L&T/ Havells/ Schneider/C&S electric(c) MCCB 250A, 4P, 415 V, 50 Hz with rupturing capacity of 36 KA(Thermal Magnetic Release + Both End Spreader Links)-01 No. Make:L&T/ Havells/ Schneider/C&S electric(d) MCCB 200A, 4P, 415 V, 50 Hz with rupturing capacity of 25 KA(Thermal Magnetic Release +Both End Spreader Links)-01 No. Make:L&T/ Havells/ Schneider/C&S electricNote:- (i) Cost includes necessary power wiring connections, MCBs 6A SP, lugs/ other accessories necessary for LT Panel as well as marking the incoming and outgoing lines on LT Panel)(ii) Contractor will approve the Drawing from Engineer-in-Charge before placing the the final order. |
| 18 | Shifting of Existing outdoor distribution LT Panel after disconnection of all incoming and outgoing cable connections, unmounting and re-mounting to new position followed by connecting new/old incoming and outgoing cables incl. necessary accessories for conncevtion viz.. lugs, clamps, conduit etc., complete all as specified and directed by Engr-in-Charge. |
| 19 | Supply, Installation, Testing & Commissioning of outdoor type Busbar Panel 415 V, 3-ph, 50 Hz capacity made out of CRCA sheet 3.15 mm thick outdoor pedestal type of size not less than 1.2m(H) x 1.0m(W) x 0.5 m(D) totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, double sided retractable roof, weather and waterproof, verminproof and having copper busbars of capacity 400 A for phase R,Y,B with heat proof colour code and mounted on insulators, danger notice plate, including connecting incoming and outgoing cables, with 40 x 40 x 6 mm angle legs of length not less than 45 cm fixed to necessary PCC 1:3:6 foundation, for fixing XLPE, armoured 415V, 400sqmm, 3.5CxAl cable in panel, complete all as specified and directed by Engr-in-Charge. |
| 20 | Supply and fix LT cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured, Al conductor cable of size 400 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 4 Core 6 to 16 Sqmm complete. |
| 22 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 4 Core 25 to 35 Sqmm complete. |
| 23 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 Core 50 to 70 Sqmm complete. |
| 24 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 Core 95 to 120 Sqmm complete. |
| 25 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 C x 400 Sqmm complete. |
| 26 | Supply, Installation, Testing & Commissioning of indoor type LT Distribution Panel 415 V, 3-ph, 50 Hz capacity, CPRI approved, made out of CRCA sheet 2.0 mm thick outdoor pedestal type, powder coated after 7 tank process polyster siemens gray structural RAL-7032 shade, totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather-dust-verminproof and waterproof having copper busbars of capacity 400 A for R,Y,B and Neutral supported on epoxy type insulator with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables, detachable gland plate at bottom for cable entry/exit, all openings to be covered with rubber gasket, with 40 x 40 x 6 mm angle legs of length not less than 45 cm above ground fixed to necessary PCC 1:3:6 foundation on ground comprising the following:- (At Sub Stn No 4) |
| 27 | Incoming:1) Automatic Transfer Switch, 400 A, 4P, 415 V, 50 Hz for two incoming and one outgoing - 01 Nos 2) MCCB 320 A, 4P, 35 KA(Thermal Magnetic Release), Rotary handlle, both end spreader links- 01 Nos 3) LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases-01 Set4) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf Make: Schinder / L&T-01 No.5) 300/5 A, 5VA, Cl-1.0 CT-01 setOutgoing:a) MCCB 200 A, 4P, 35 KA(Thermal Magnetic Release), Rotary handlle, both end spreader links- 02 Nos (For Pump house no 4 & spare ) |
| 28 | b) MCCB 125 A, 4P, 35 KA(Thermal Magnetic Release), Rotary handlle, both end spreader links- 03 Nos (For DSC Line)c) MCCB 32 A, 4P, 25 KA(Thermal Magnetic Release), both end spreader links- 02 Nos (Street Light & SS No. 4)d) 415 V, 20 A, 3-ph Timer Switch with contactor - 01 NoNote:- (i) Cost includes necessary power wiring connections, MCBs 6A SP, lugs/ other accessories necessary for LT Panel as well as marking the incoming and outgoing lines on LT Panel)(ii) Contractor will approve the Drawing from Engineer-in-Charge before placing the the final order. |
| 29 | M & L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed), grade cross sectional area 120 sq. mm x 3 core all complete. |
| 30 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm.Make: Denson/Raychem/3M |
| 31 | Supply, Installation, testing & commissioning of 120 KVAR Automatic Power Factor Correction (APFC) Panel 415 V AC, 3-ph, 50 Hz with MPP-H capacitor in 08 steps with microprocessor controlled power factor controller, LED indicators, Multifunction meter, Auto/Manual selector switch and other associated components, enclosure fabricated out of CRCA steel sheet 2mm thick and 3.2 mm for gland plate incl gland with powder coated paint treated over seven tank process TPN EC Copper Bus Bars supported on DMC/SMC insulators, of rating 250A, colour coded heat shrinkable sleeves and suitable earthing Al busbar conforming to IS with danger notice plate, legends/labels on Al Anodized Black Plate with white engraved letters, door lock mechanism, necessary cable glands, cable connection with proper lugs, sleeves, etc., with 200 A, 4P MCCB at incoming all complete and as directed by Engr-in-Charge. |
| 32 | Shifting of Existing APFC Panel after disconnection of all incoming and outgoing cable connections, unmounting and re-mounting to new position followed by connecting new/old incoming and outgoing cables, incl. necessary accessories for conncevtion viz.. lugs, clamps, conduit etc., complete all as specified and directed by Engr-in-Charge. |
| 33 | Supplying and laying unreinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm Please Enable Macros to View BoQ information |
| 34 | Supplying and laying unreinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm Please Enable Macros to View BoQ information |