Tender For Kharkhoda: Construction Of 4.50 Mld Average Flow Mps With Peak Factor 2.50 For Existing Stp And Pumping Station For Treated Effluent Including Collecting Tank For T.E, Pump Chamber, Rising Main Line, Pumping Machinery, D.G Set, Manhole And, Kharkhoda-Haryana
TDR : 55684646
Tender Notice
BOQ
9 Days Left
Kharkhoda
Haryana
Tender For Kharkhoda: Construction Of 4.50 Mld Average Flow Mps With Peak Factor 2.50 For Existing Stp And Pumping Station For Treated Effluent Including Collecting Tank For T.E, Pump Chamber, Rising Main Line, Pumping Machinery, D.G Set, Manhole And
Name of Work:- KHARKHODA: Construction of 4.50 MLD average flow MPS with peak factor 2.50 for existing STP and pumping station for treated effluent including Collecting tank for T.E, pump chamber, Rising main line, pumping machinery, D.G set, Manhole and repair of existing structures etc. at Kharkhoda Town including 3 years defect liability period complete in all respect. App Cost of Rs. 234.98 Lakh
Sl. No.
Item Description
1
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (50 Sqmm size)
2
PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 3400 LPM x 20 .00 M Head
3
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications with PN 1.6 complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026 Dated on: 13 April 2026) 200 mm dia
4
`MPS (MAIN PUMPING STATION): Design, construction and commissioning of MPS for 4.50 MLD average flow with peak factor 2.5 including RCC Inlet chamber, suitable size flow meter, screening chamber, wet well sump complete in all respect as per detail and specifications mentioned in attached additional documents along with following provisions:1.1 Suitable size (as per design) K9 DI pipe at MPS for interconnecting the structures including welding and screwing of flanges, ISI marked D.I. fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respect1.2 Suitable size (as per design and requirement) Gear Operated Sluice Gate with Rising Spindle for screens and partition of tank as per design.1.3 Supply and installation of 2 mechanical coarse screen (SS 316) suitable for 4.50 MLD average flow with peak factor of 2.5 complete in all respect.1.4 Conveyance of raw sewage from MPS to inlet chamber of STP through suitable size (as per design) DI pipe along with cost of DI pipe, sluice valves, specials, material and labour complete in all respect.1.5 Raw sewage will be available near boundary wall within the premises of proposed MPS but the conveyance of sewage from this terminal point to the inlet chamber of MPS through DI K9 pipe of suitable diameter as per design is included in the Turnkey contract. The Level of the MPS / STP will be as per bed level of existing incoming sewer at MPS`
5
HSR Itmes Please Enable Macros to View BoQ information