| 1 | Cartage of following material from Store centre, Mathura to work site. | Cartage of following material from Store centre, Mathura to work site. |
| 2 | 11 Mtr. Long PCC Pole | 11 Mtr. Long PCC Pole |
| 3 | 8.5 Mtr. Long PCC Pole | 8.5 Mtr. Long PCC Pole |
| 4 | 11/0.4 KV 63 KVA T/F. | 11/0.4 KV 63 KVA T/F. |
| 5 | 11/0.4 KV 100 KVA T/F. | 11/0.4 KV 100 KVA T/F. |
| 6 | 11/0.4 KV 250 KVA T/F. | 11/0.4 KV 250 KVA T/F. |
| 7 | LT ABC (3x50+1x35+1x16) Sqmm. | LT ABC (3x50+1x35+1x16) Sqmm. |
| 8 | LT ABC (3x95+1x70+1x16) Sqmm. | LT ABC (3x95+1x70+1x16) Sqmm. |
| 9 | LT ABC 3.5x50 Sqmm. | LT ABC 3.5x50 Sqmm. |
| 10 | LT ABC 3.5x95 Sqmm. | LT ABC 3.5x95 Sqmm. |
| 11 | LT ABC 3x120 Sqmm. | LT ABC 3x120 Sqmm. |
| 12 | LT PVC cable 1x240 sq.mm. | LT PVC cable 1x240 sq.mm. |
| 13 | LT PVC cable 1x400 sq.mm. | LT PVC cable 1x400 sq.mm. |
| 14 | LT PVC cable 3.5x70 sq.mm. | LT PVC cable 3.5x70 sq.mm. |
| 15 | LT PVC cable 3.5x150 sq.mm. | LT PVC cable 3.5x150 sq.mm. |
| 16 | Distribution Box | Distribution Box |
| 17 | 11 KV Polymer Pin Insulator with Pin | 11 KV Polymer Pin Insulator with Pin |
| 18 | 11 KV Disc. Insulator T&C type 45KN | 11 KV Disc. Insulator T&C type 45KN |
| 19 | 11 KV Disc Fitting T&C type 45KN | 11 KV Disc Fitting T&C type 45KN |
| 20 | 11 KV Fuse set | 11 KV Fuse set |
| 21 | ACSR Weasel conductor | ACSR Weasel conductor |
| 22 | Stay Set complete | Stay Set complete |
| 23 | Digging of pit & erection of new single support PCC Pole (8.5 mtr. long) | Digging of pit & erection of new single support PCC Pole (8.5 mtr. long) |
| 24 | Digging of pit & erection of new Double Pole Structure PCC Pole (8.5 mtr. long) | Digging of pit & erection of new Double Pole Structure PCC Pole (8.5 mtr. long) |
| 25 | Digging of pit & erection of new Double Pole Structure PCC Pole (11 mtr. long) | Digging of pit & erection of new Double Pole Structure PCC Pole (11 mtr. long) |
| 26 | Providing & fixing of MS Dropper Channel 100x50x2028mm. | Providing & fixing of MS Dropper Channel 100x50x2028mm. |
| 27 | Providing & fixing of MS T-off Channel 125x65x1300mm | Providing & fixing of MS T-off Channel 125x65x1300mm |
| 28 | Providing & Layingt of Ins. Weasel conductor | Providing & Layingt of Ins. Weasel conductor |
| 29 | Laying of Weasel conductor | Laying of Weasel conductor |
| 30 | Earthing of Pole by MS Earth Rod | Earthing of Pole by MS Earth Rod |
| 31 | Earthing of T/F. Body & Neutral by MS Earth Rod | Earthing of T/F. Body & Neutral by MS Earth Rod |
| 32 | Providing & Fixing of 'F' Bracket with Nut & Bolts | Providing & Fixing of 'F' Bracket with Nut & Bolts |
| 33 | Fixing of 11 KV Disc Insulator T&C type 45 KN | Fixing of 11 KV Disc Insulator T&C type 45 KN |
| 34 | Fixing of 11 KV Disc Fitting T&C type 45 KN | Fixing of 11 KV Disc Fitting T&C type 45 KN |
| 35 | Fixing stay set complete | Fixing stay set complete |
| 36 | Concreting of Pole | Concreting of Pole |
| 37 | Providing & fixing of Suspension clamp with I Hook | Providing & fixing of Suspension clamp with I Hook |
| 38 | Providing & fixing of Dead End clamp with I Hook | Providing & fixing of Dead End clamp with I Hook |
| 39 | Providing & fixing LT Pin Clamp | Providing & fixing LT Pin Clamp |
| 40 | Providing & fixing of Stone Pad 300x300x75mm | Providing & fixing of Stone Pad 300x300x75mm |
| 41 | Providing & fixing Copper L-piece 62x225x12 mm | Providing & fixing Copper L-piece 62x225x12 mm |
| 42 | Providing & Fixing Clamps for LT T-off with bolts & nut | Providing & Fixing Clamps for LT T-off with bolts & nut |
| 43 | Providing & Fixing Holding clamps for Top Channel TPMO & Fuse set with Nut & Bolts | Providing & Fixing Holding clamps for Top Channel TPMO & Fuse set with Nut & Bolts |
| 44 | Providing & Fixing MS Angle 75x75x6x2028m, with clamps & bolts | Providing & Fixing MS Angle 75x75x6x2028m, with clamps & bolts |
| 45 | Providing & Fixing MS Top Channel 125x65x2240mm | Providing & Fixing MS Top Channel 125x65x2240mm |
| 46 | Providing & Fixing Danger Board, barbed wire including jumper | Providing & Fixing Danger Board, barbed wire including jumper |
| 47 | Fixing of 11 KV Polymer Pin Insulator with Pin | Fixing of 11 KV Polymer Pin Insulator with Pin |
| 48 | Laying & Connecting LT ABC 3.5x50 Sqmm. | Laying & Connecting LT ABC 3.5x50 Sqmm. |
| 49 | Laying & Connecting LT ABC 3.5x95 Sqmm. | Laying & Connecting LT ABC 3.5x95 Sqmm. |
| 50 | Laying & Connecting LT ABC 3x120 Sqmm. | Laying & Connecting LT ABC 3x120 Sqmm. |
| 51 | Laying & Connecting LT ABC (3x50+1x35+1x16) Sqmm. | Laying & Connecting LT ABC (3x50+1x35+1x16) Sqmm. |
| 52 | Laying & Connecting LT ABC (3x95+1x70+1x16) Sqmm. | Laying & Connecting LT ABC (3x95+1x70+1x16) Sqmm. |
| 53 | Laying & connecting LT PVC cable 3.5x70 Sqmm. | Laying & connecting LT PVC cable 3.5x70 Sqmm. |
| 54 | Laying & connecting LT PVC cable 3.5x150 Sqmm. | Laying & connecting LT PVC cable 3.5x150 Sqmm. |
| 55 | Installation of Distribution Box | Installation of Distribution Box |
| 56 | Providing & Fixing clamp for Distribution Box | Providing & Fixing clamp for Distribution Box |
| 57 | Providing & Installation LT Fuse Set Protection Unit for 100 KVA DT with SMC Box | Providing & Installation LT Fuse Set Protection Unit for 100 KVA DT with SMC Box |
| 58 | Providing & Installation LT Fuse Set Protection Unit for 63 KVA DT with SMC Box | Providing & Installation LT Fuse Set Protection Unit for 63 KVA DT with SMC Box |
| 59 | Providing & Installation LT Fuse Set Protection Unit for 25 KVA DT with SMC Box | Providing & Installation LT Fuse Set Protection Unit for 25 KVA DT with SMC Box |
| 60 | Providing & Installation Henley type Tailless Unit Protection Cubical Panel 500A, 650V for 250 KVA T/F. | Providing & Installation Henley type Tailless Unit Protection Cubical Panel 500A, 650V for 250 KVA T/F. |
| 61 | Providing & Fixing of Al. Leg long barrel off size | Providing & Fixing of Al. Leg long barrel off size |
| 62 | Laying & connecting LT PVC cable 1x240 sq.mm. | Laying & connecting LT PVC cable 1x240 sq.mm. |
| 63 | Laying & connecting LT PVC cable 1x400 sq.mm. | Laying & connecting LT PVC cable 1x400 sq.mm. |
| 64 | Installation of 11 KV Fuse Set | Installation of 11 KV Fuse Set |
| 65 | The Construction of new Plinth of Size 2x2x1.5 Mtr. = 06 CuMtr. | The Construction of new Plinth of Size 2x2x1.5 Mtr. = 06 CuMtr. |
| 66 | Installation of following transformer on Plinth/Double pole with all connecting accessories jumering etc. | Installation of following transformer on Plinth/Double pole with all connecting accessories jumering etc. |
| 67 | 63 KVA Transformer on Double Pole Structure | 63 KVA Transformer on Double Pole Structure |
| 68 | 100 KVA Transformer on Double Pole Structure | 100 KVA Transformer on Double Pole Structure |
| 69 | 250 KVA Transformer on Plinth | 250 KVA Transformer on Plinth |
| 70 | Mesh fencing for T/F. h=1.82Mtr. Xw = 3.25Mtr. = 4xhxw = 23.66 Sqmm. | Mesh fencing for T/F. h=1.82Mtr. Xw = 3.25Mtr. = 4xhxw = 23.66 Sqmm. |
| 71 | Chemical Earthing of Transformer | Chemical Earthing of Transformer |
| 72 | Dismantling existing 10 KVA T/F. (02 No.) and cartage from work site to store center, mathura | Dismantling existing 10 KVA T/F. (02 No.) and cartage from work site to store center, mathura |
| 73 | Dismantling existing 16 KVA T/F. (05 No.) and cartage from work site to store center, mathura | Dismantling existing 16 KVA T/F. (05 No.) and cartage from work site to store center, mathura |
| 74 | Dismantling existing 25 KVA T/F. (13 No.) and cartage from work site to store center, mathura | Dismantling existing 25 KVA T/F. (13 No.) and cartage from work site to store center, mathura |
| 75 | Dismantling existing 63 KVA T/F. (12 No.) and cartage from work site to store center, mathura | Dismantling existing 63 KVA T/F. (12 No.) and cartage from work site to store center, mathura |
| 76 | Dismantling existing 100 KVA T/F. (48 No.) and cartage from work site to store center, mathura | Dismantling existing 100 KVA T/F. (48 No.) and cartage from work site to store center, mathura |
| 77 | Dismantling existing 100 KVA T/F. (07 No.) and cartage from work site to store center, mathura | Dismantling existing 100 KVA T/F. (07 No.) and cartage from work site to store center, mathura |