Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | NAME OF WORK Miscellaneous Civil, PH, Internal Painting & Electrical work in Vacant flats under TTM-III Unit At Anushaktinagar, Mumbai NIT NO DCSEM/CQD/QSB/TTM-III-Vacant/26-27/NIT/20 dt.26.05.2026 GENERAL NOTES: |
| 2 | The site is situated at Anushaktinagar, Mumbai |
| 3 | The tenderers are advised to visit the site of work & its surroundings, with prior permission of Engineer-in-charge/authorised representative, to acquaint themselves about the location of work, accessibility to the site, level of sub-soil water, drainage facility for dewatering and any other matter relating to availability and carriage of construction materials, nature of work etc., and satisfy themself and then quote the rates accordingly. A Tenderer shall be deemed to have full knowledge of the site whether he inspects it or not and NO extra charges consequent on any misunderstanding or otherwise shall be allowed. |
| 4 | Tenderers shall visit the site of work, at their own cost. The request email for site visit shall be sent well in advance (preferably three working days before) for preparation of visitor pass, fixing suitable & mutually agreed date & time for site visit. The email ID for site visit is mentioned in tender documents. |
| 5 | Contractor is fully responsible for making payment of Minimum wages & Bonus to labourers, EPF & ESI to statutory Authorities timely and submission of challans and documentary proof to EIC for release of payment of Running Account / Final Bill. Otherwise, bill will not be forwarded by EIC to Accounts for payment. EIC should ensure that all necessary documents are submitted by Agency for release of payment. No Running Account / Final Bill shall be paid for the work till the applicable labour license, registration and challans with EPFO, ESIC and BOCW (Building and Other Construction Workers) Welfare Board, whatever applicable, are submitted by the Contractor to the Engineer-in-Charge.) |
| 6 | Contractor shall take a Contractor’s All Risk (CAR) Insurance Policy in respect of entire scope of work and a Janata insurance policy to cover the compensation claims arising out of Workmen's Compensation Act-1923. The Insurance policy shall be taken for entire period of contract and copy of the same shall be submitted to the Engineer-in-Charge before commencement of the work. The insurance policy shall be taken before commencement of the work and shall be renewed during the construction period till actual completion of work. The charges for issue & renewal of insurance policy shall be borne by Contractor. In event of failure of the Contractor to obtain Insurance Policy, Running Account Payments of the Contractor shall not be released till such time the same is obtained by the Contractor & submitted to the Engineer-in-Charge. In case, Insurance Policy has validity period not matching with contract period (either due to policy start date later than actual date of start of work or policy end date earlier than actual date of completion), then penalty for gap in period shall be levied at one and half times the rate of Insurance Policy premium including GST, to be computed on per day basis. All the workers engaged on the work shall required to be insured as per Government norms at the cost of contractor. |
| 7 | The Contractor shall submit with every Running Account / Final Bill, a certificate of employment/deployment of the Technical representative(s) as per Clause 36 (i) in Schedule 'F' of \\" Salient Governing Features of the Tender\\", after certifying by Engineer-in-Charge. In the event of not fulfilling the above provisions of Clause 36(i), recovery shall be made from the contractor as per Schedule 'F'. |
| 8 | Arrangement of Electricity : as per Schedule -BElectricity for construction work will be supplied by department @ free of cost. |
| 9 | Arrangement of Water : as per Schedule -BWater will be supplied by department and water charges will be recovered @1% of gross value of work done. |
| 10 | The drawings issued for Tender purpose are preliminary and indicative only. The Working drawings as applicable shall be issued in phased manner at the time of execution. Nothing extra shall be entertained towards revision in drawings. Drawing shall not be taken outside campus/site/premises without Gate Pass issued by EIC. |
| 11 | All the items of sub-structure include the cost of dewatering and shoring, wherever necessary, during the progress of work, till its completion without any extra cost to the Department. |
| 12 | The Schedule of Quantities include contingent works for other services (PHE, Electrical, Mechanical etc.) which shall be paid under relevant Civil items. Accordingly, the Contractor shall carry out all related works such as making cut outs, nitches, pipe sleeves, foundation pockets for embedded plate, bolts, parts etc. in concrete/ brick works as and when required by Engineer-in-charge without any extra cost to the Department. |
| 13 | PPC/ Blended cement of recommended brand shall only be used for all masonry and finishing works unless noted otherwise. Only Fully treated dry, well graded sand conforming to IS 383 shall be used. |
| 14 | Only Ready Mix Mortar of approved make shall be used. The ready mix mortar shall be manufactured by preferred manufacturers, using cement-sand in required proportion. |
| 15 | The size and thickness of natural stones/ tiles mentioned for flooring dado, skirting etc. are approximate and subject to the availability in market during execution. If the required size and thickness is not available, the next higher size and thickness of tiles/ stones shall be used without any extra cost to the Department. The contractor may quote the rates accordingly. |
| 16 | Quoted rate shall hold good for plain/ curved/ any other geometric shapes & sizes of all structural/ RCC members including formworks, masonry, flooring, doors & windows, plastering, painting etc. at all leads, levels, lifts and floors including scaffolding, bracing, multilevel staging etc., unless noted otherwise. Nothing extra shall be entertained towards wastages of materials, additional labours/ tools & plants etc. to achieve the required shapes & sizes etc. |
| 17 | The Contractor shall follow the DAE safety rules strictly. All safety & security regulations shall be followed strictly as per specifications & conditions of contract. |
| 18 | The following Security regulations shall be followed strictly while movement of labourers/ workers/ contractor's personnel including transportation of the materials etc. i) The Workers, Engineers and Supervisors will be provided vigil passes (for entry into Premises) on submission of application forms in prescribed formats supported by documentary proof like Aadhar card, Voter ID card and Ration Card / Driving Licence / PAN card etc. Police Verification Certificate (PVC) is mandatory for Engineers and Supervisors (wherever desired by department). You are requested to obtain immediately Police Verification Certificate (PVC) of your regular staff deployed at site(s) in respect of works and submit the same along with necessary application to allow them to enter in premises to carry out the assigned work. ii) The Contractor shall obtain special permission for working on extended hours of working days including Saturday, Sunday and holidays etc. iii) Workers shall be escorted from the main gate of campus/premises upto the site by designated supervisors of the contractor and they are not allowed to roam around inside the premises. iv) Transport vehicles of the contractor are allowed to enter the premises for transportation of construction materials. Drivers must have valid driving license of Heavy Vehicle. v) The following Security regulations shall also be followed strictly while movement of labourers/ workers/ contractor's personnel etc. (a) The Contractor shall issue I-Cards to his workers deployed on regular basis. (b) The Supervisor of the contractor having photo pass can bring daily wage workers/ casual workers inside campus for work. He should prepare list of such workers in duplicate. The original copy shall be handed over to the representative of the Engineer-In-Charge at the gate and endorsement obtained on duplicate copy on daily basis. (c) The Contractor's personnel including daily wage workers shall be in uniform with proper identification for ease in identification of such persons at unauthorised places. (d) The daily wage workers/ casual workers employed by the contractor must wear florescence vis-a-vis wear without fail during their presence inside Campus/premises. The contractor shall provide a sleeveless Jacket to the workers in pattern, colour showing name of contractor with address and telephone number as approved by the Engineer-in-charge. All the workers must wear the same while on duty. (e) The Contractor's personnel shall follow all safety rules & security procedure that are in vogue and applicable during execution of work. Contractor shall verify the character and antecedents of the labourers employed, through local address proof issued by competent authorities such as Aadhar card, Voter ID card and ration card / driving license /electricity bills /telephone bill /gas connection document etc. The nationality of contract labourers also needs due verification. |
| 19 | Vehicular movement shall abide by the regulations imposed by the concerned authorities. The contractor shall abide by the security rules & regulations of the Department. The approach roads should be kept clean & free from obstruction for smooth functioning of existing traffic and damages caused, if any, to be made good without any extra cost to the department. Contractor may make provision for entry of vehicles by providing alternate road/ route for entry & exit during the construction work, if required, at his own cost without extra cost to the department. |
| 20 | While transporting materials from site and disposal of surplus materials, the spilled over materials/ earth/ debris etc. on the road should be got cleaned by the contractor after the day's work is over. |
| 21 | Royalty for excavation, transportation, filling of earthwork etc. including obtaining permission from Statutory authority, if any, shall be borne by the contractor. |
| 22 | Regarding disposal of Construction waste from site of work, the agency has to abide by the guidelines of Construction and Demolition (C&D) waste management plan as approved by BMC/Local Municipal Authority and any other regulations issued by Statutory authorities in the matter from time to time and Department is not responsible in any way in this regard. i) Contractor shall strictly follow the Statutory rules and regulations of the Construction and Demolition Debris Management Plan for project site. ii) Surplus Excavated materials and construction debris shall be disposed from construction site at approved disposal ground of BMC/Local Municipal Authority including cost of necessary Statutory charges, as applicable. iii) Contractor shall submit acknowledgement of challan for each trip for unloading of Construction and Demolition waste material as per the standard format. iv) Contractor shall be responsible and liable for penalty, if any, as prescribed by the Local Authority in case of non-fulfilment of the procedure laid down in the Construction and Demolition Debris Management Plan. v) Contractor shall submit irrevocable Bank Guarantee for the amount as insisted by BMC/Local Municipal Authority for the purpose of ensuing compliance of the Waste Management Plan/Debris Management Plan approved by the Local Municipal Corporation from time to time, till the grant /issuance of the Occupation Certificate and charges for same will be borne by Contractor. NOC from C&D Waste Management Department of BMC/Local Municipal Authority shall be submitted by the agency. |
| 23 | Agency should pay necessary charges to BMC/Local Municipal Authority to get done periodical pest control / anti-larva treatment / Insecticide treatment at Construction site. After the completion of work, necessary NOC shall be obtained from BMC /Local Municipal Authority and shall be submitted to Department. The charges for same will be borne by Contractor. |
| 24 | The Agency shall take care of existing services and other department properties while carrying out job. All dismantling, demolishing and excavation work shall be done with most careful manner and with prior written approval of the Engineer-in-charge, without damaging the existing structures, services, finishes, etc. Agency shall take all precautions to cover all furniture, fixtures, glass and window panes to prevent damage. Damage, if any shall be repaired/replaced by agency at his own cost. |
| 25 | Protection of work: The Contractor shall be responsible for the protection of the work during progress. He shall also provide and maintain any other temporary substitute and material for this purpose. He shall take all the necessary precautions to prevent damage to all the works till its handing over. |
| 26 | Wherever old material/works are replaced with new one, quoted rate includes removing/dismantling the existing one and depositing the serviceable material at departmental store and disposing off debris outside the campus/ premises/ colony. |
| 27 | Since the work has to be carried out inside/ near occupied residential/office building, the work shall be executed with least disturbance to occupants of buildings. |
| 28 | Approved Samples of Materials: The Contractor shall submit samples of all materials to be incorporated in the work, without any extra cost to Department, at least 30 days before he places bulk order for the materials and shall obtain approval of samples in writing from the Engineer-In-charge. |
| 29 | Shop drawings for Aluminium work, Structural steel, Stainless steel, Structural glazing, ACP cladding, etc. shall be submitted by Contractor for the approval of Engineer-in-Charge, at least 30 days in advance prior to taking of work. |
| 30 | No labour shall be permitted to stay inside campus/premises/site. |
| 31 | Suitable area near site of work shall be allocated to the contractor for storing construction materials, for site office etc. Optimum care shall be taken by the contractor to avoid disturbing the traffic and road around the building etc. The contractor shall have to maintain proper co-ordination with the fellow agencies working simultaneously in the vicinity of subject work in order to avoid delays in any of the works going on in and around the premises. |
| 32 | Guidelines for Air Pollution mitigation(i) The charges for the Air Pollution mitigation measures shall be borne by the contractor without any extra cost to the department.(ii) Contractor shall follow the directions for Dust and Pollution Control measures in construction as notified by MoEF&CC / MoHUA / CPWD / BMC or any other statutory authority.(iii) All precautionary measures for control of Air Pollution due to Building Construction Activity shall be taken as per Local Statutory/ Municipal Authority Air Pollution Mitigation Plan. (iv) Mandatory Form for Building Construction activity to control Air Pollution along with supporting documents and site photographs shall be submitted to concerened authority or uploaded on online portal.(v) Projects attracting Environmental Clearance shall carry out Third Party Ambient Air Monitoring every fortnightly from NABL / MoEF&CC laboratory. (vi) Construction projects shall mandatorily install sensor-based air quality monitor for measuring PM concentration (PM2.5 and PM10), relative humidity, temperature and display real time AQI data through LED display board (width 1220mm x height 915mm, screen resolution 320 x 192 pixel) at the construction site. Further, installation must be completed within 15 days of issue of Work order or commencement of work. The Contractor shall submit a certificate for completion of installation of air quality monitor and LED display board, after certifying by Engineer-In-charge, along with 1st RA bill for releasing the payment.(vii) The air quality data must be accessible at the site and made available for inspection by Local Municipal Authority/ Competent Authority.(viii) Construction layouts having area more than 01 (one) acre or Height more than 70m, shall have continuous dust or wind breaking tin / metal sheet erected of minimum height 35 feet around periphery of the construction project site and for construction site, less than 01 (one) acre, the tin / metal sheet height shall be 25 feet minimum.(ix) Tarpaulin / Green cloth / Jute sheet to be mandatorily used to cover the floor where any construction activity is in progress and two floors below it and also on scaffolding covering an entire area under demolition structure. Further, regular cleaning of Tarpaulin / Jute sheet to be undertaken. (x) Water sprinkling shall be continuously carried out so that the debris shall remain in wet condition.(xii) All vehicles carrying construction materials/waste/debris shall have valid PUC certificates and the same shall be produced as when asked for by competent authorities.(xiii) Construction workers should mandatorily use PPE (Personal Protective Equipment) i.e. Mask, Goggles etc. |
| 33 | The quoted rate shall be inclusive of providing and erecting temporary barricading of height as per above 'Guidelines for Air Pollution mitigation' (but minimum 10 feet height) using structural steel (MS Pipes or angle iron frame work etc.), covered with tin / GI sheets of approved colour & shade, Struts, MS Clamps, Bracing etc. and shall have wicket gate & material gate and including writing and painting of direction & instructions, providing glow lamps, reflective signs, marking, flags, caution tape etc. Prior written approval of Engineer-in-Charge of the sketch/ drawing showing details of barricading shall be obtained by the contractor. The barricading shall be provided and retained in position at site continuously during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour, materials, equipments and works required to execute the job such as earth work, concrete, welding etc. After completion of work, Contractor shall remove and take away the barricading at his own cost with the prior approval of Engineer-In-Charge. The entire work shall be executed as per direction of Engineer-In-Charge. No work shall be allowed unless the barricading is completed to the satisfaction of the Engineer-in-Charge. The Contractor shall submit a certificate for completion of barricading along with 1st RA bill after certifying by Engineer-in-Charge for releasing the payment. |
| 34 | The contractor shall display proper information/cautionary signage boards at site for the safety of the workers and public in general in the surrounding areas. |
| 35 | Contractor has to provide sign board at site with detailed name of project, name of client, name with contact number of contractor and minimum wages category wise at entrance of project/site without any extra cost to the department. |
| 36 | Guidelines for Scaffolding works - Quoted rates shall include all scaffolding works without any extra cost to the department.(i) Design of scaffolding for carrying out work shall be as per relevant IS Codes & specification. The contractor has to observe all safety procedure while working on heights as per IS: 3696 (Part-I) (Safety Code for Scaffolds). (ii) All working platform must be of minimum 600 mm wide, made of M.S pipe and must have guard rails as per specification. Further, Overhead protection should be provided on the scaffolds to protect workers on lower platform against falling objects from higher level.(iii) Necessary ladder shall be provided at required locations to enable Departmental Staff for supervision of works.(iv) Labours working on the scaffolding should be with safety belts, helmets, goggles and other safety gears.(v) Horizontal Safety Net : Nylon net with a mesh size of 25mm shall be provided at 4.0 meter height from the ground level around the buildings upto a distance of minimum 3.0 meter from the edge of the building on all sides to catch any falling objects.(vi) Vertical Safety Net: Green cloth net shall be provided to the full height of scaffolding / building and securely tied to protect falling material coming out during the progress of work. |
| 37 | Maintaining L1 position During execution of the contract, if tender structure changes due to variation in quantities (i.e Work order quantities, Substituted items quantities including quantities within deviation limit specified in Clause 12 of Schedule ‘F’ in “Salient Governing Features of the Tender”), Contractor has to give suitable discount to remain in L1 position. |
| 38 | The quoted rates shall be inclusive of wastage of labour & material, installation, testing, commissioning, transportation, loading, unloading, lifting etc. and also includes provision of all necessary manpower, tools, machinery, equipment, hoists etc. for carrying out the work in effective manner as per specifications and as directed by Engineer-In-Charge. |
| 39 | The quoted rates shall be inclusive of all Taxes, GST, Cess, Levy, duty etc. |
| 40 | Refer Prebid clarifications, minutes of meeting & corrigendum for revisions, if any, for updates. |
| 41 | The work is to be carried out in vacant flats of occupied buildings, hence the work shall be carried out with least disturbance to the residents. |
| 42 | The Job card for each flat shall be issued on weekly basis, Work shall be completed in all respects in maximum of 30 Days. If agency fails to complete the work in stipulated time frame, a penal recovery of Rs. 1500 per flat per day shall be levied. Decision of Engineer-In-Charge shall be final and binding to agency. |
| 43 | The agency shall have to commence the work and execute an average of Seven flats per week, subject to availability of flats. |
| 44 | The contractor shall provide sleeveless Jackets to the workers in required pattern, colour showing name of contractor with address and telephone number as approved by the Engineer in charge. All the workers must wear the same while on duty. |
| 45 | i) No debris shall be left over around the building during the renovation works. An area for 'Debris bins' will be identified close to his site office or inside Anushaktinagar colony at the location identified by EIC on the request of contractor for collection of debris generated on day to day basis. The Debris from debris bin shall be cleared every month. The contractor must maintain adequate number of wheel borrows all the time for shifting the debris to Debris bin. If the debris lies around the building for more than 2 days, penalty @ Rs. 500/- per day per flat shall be levied w.e.f. 3rd day onwards.ii) The debris generated shall be disposed by mechanical transport to the nearest dumping pit inside Anushaktinagar colony as directed by EIC with all leads, loading, unloading etc. complete. No payment shall be released unless certificate from EIC showing clearance of debris is produced in each RA bill and Final bill. |
| 46 | Penal recovery shall be made at the rate of Rs. 1500/- per flat per day, if water taps / bib cocks, flushes etc. are left open. In case of any further material loss due to this negligence in other flats, same will have to be borne by contractor. |
| 47 | The cement sand mortar use shall be factory manufactured pre mix/ready mix of 'Roofit Mix 'of M/ s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/sWalplast Products pvt.ltd/ 'Readiplast' of M/s UltratechCement Ltd or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties,mechnical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer. |
| 48 | PART A : CIVIL WORKS |
| 49 | PART B : PH WORKS |
| 50 | PART C : ELECTRICAL WORKS |
| 51 | PART D : REBATED ITEMS |
| 52 | PART I : CIVIL WORKS |
| 53 | Repairing of loose / shaky vitrified tile flooring/ green marble/granite stone frames at all floors and levels using polymer modified cement based tile adhesive manufactured by Roffe Construction – NSA (Non Skid Adhesive) or M/s Bal Endura Chemicals– Gold Star or other approved equivalent. The repairing process will consists of following.(1) Complete checking by tapping of affected flooring area using solid wooden stick. Identifying the affected tiles for repair work. (2) Drilling holes through tiles and widenining of tile joints using cutter as per requirement. (3) Breaking of tiles and removing backing adhesive from original flooring, cleaning etc (If Required). Checking the original flooring by tapping using solid wooden stick and repairing of original flooring by breaking the original mosaic / cement tile flooring and filling with 1:4 ready mix cement sand mortar, curing etc complete. (4) Grouting the tile flooring using tile adhesive slurry through drilled holes, widened joints, opening made by tile breaking using trowel etc and by tapping of floor tiles etc. (5) Sealing of drilled holes, widened joints using white cement cleaning of flooring, removal of debris and disposal of debris inside colony. (6). Removing and refixing of Aluminium window/door shutter/MS grill for repairing work, after the repairing works (7) Complete checking by tapping of repaired flooring area using solid wooden stick after 7 days of repairing work in presence of departmental representative. The repaired work shall not make any hollow sound, loose/shaky motion of tiles. The entire repairing work shall be carried out as per direction and instructions of engineer-in-charge.' |
| 54 | (a) Area of flooring for which grouting of joints and backing mortar done using tile adhesive. |
| 55 | (b) Removing loose / shaky vitrified floor tiles and refixing the same using polymer modified cement based tile adhesive manufactured by Roffe Construction – NSA (Non Skid Adhesive) or M/s Bal Endura Chemicals– Gold star, including removal of loose/shaky tiles cleaning back side of tile and removal of tile adhesive from existing floor area, cleaning etc complete all as per specifications and as directed by the Engineer-In-Charge. |
| 56 | Providing and laying at all floors and levels Vitrified tiles of first quality Marbonite of M/S H&R JHONSON (INDIA) Ltd or other equivalent approved make of approved colour, shade, pattern and of thickness as per manufacture's specifications, laid directly over tile, using polymer cum cement based adhesive (Type -II as per IS) manufactured by M/S Roffe construction or M/s Bal Endura chemicals or other approved equivalent in respect of flooring and fixed over 12 mm thick backing using ready mix cement mortar 1:4 in respect of skirting , close jointed and grouted white /colour cement slurry with pigments to match the colour of the tiles, finished to level, line, slope and plumb including cutting of tiles, making openings / cut out where necessary including wastage for odd shape of room and final cleaning of surfaces as required, curing etc. complete all as per specification,relevent IS code & as directed by the EIC. |
| 57 | a) In flooring with tiles of approx. size 600 mm x 600 mm similar to Salt & Pepper (White/Grey)/ Rigato/Athelon of M/s H& R Johnson (I) ltd. Or similar tile of other approved make, laid directly over existing tile using tile on tile polymer cum cement based adhesive. |
| 58 | b) In Dado / skirting with tiles of size 600 x 100 mm similar to Salt & Pepper (White/Grey)/ Rigato/Athelon of M/s H& R Johnson (I) ltd. Or similar laid over 12 mm thick ready mix cement mortar 1:4 backing, jointed with cement slurry & grouted with pigment of matching shade & finishing the top of skirting etc. complete, including dismantling the existing dado/skirting tile and backing cement mortar disposal of debris etc. complete. |
| 59 | Providing & laying at all floors & levels first quality ceramic tiles of minimum thickness as specified by the manufacturer of M/S. H&R JOHNSON (INDIA) Ltd. or equivalent approved make of approved colors, shade and texture in flooring / dado / skirting as per approved pattern. incluidng cost of all materials, including cutting the tiles to required shape, wastage, pointing the joints with white cement mixed with matching pigments to match the colour of the tiles, finished to line, level, slope & plumb, final cleaning of surface as required, curing , making necessary opening cutouts etc.and including removing existing flooring / dado and disposing of debris inside Anushaktinagar colony at the identified locations complete all as per specifications, relevant IS code & as directed by the EIC. |
| 60 | a) In flooring with tiles of size 300 x 300 ( approx size ) Digital HD series of M/s H& R Johnson or equivalent approved make with 20 mm thick 1:4 Cement mortar bedding (Using factory made Ready Mix Mortar only) |
| 61 | b) In flooring with anti skid tiles of size 300 x 300 mm x 12 mm th ( approx size) Checkered Ivory of Endura tiles of M/s H& R Johnson or approved equivalent with 20 mm thick 1:4 Cement mortar bedding (Using factory made Ready Mix Mortar only) |
| 62 | c) In dado / Skirting with tiles of 300X450mm (Approx size) of Digital HD Series of M/s H&R johnson (India) Limited or approved equivalent fixed over 12 mm thick 1:4 cement mortar (Using factory made Ready Mix Mortar only) backing / fixed directly over existing tile with polymer cum cement based tile adhesive manufactured by M/s. Roffe construction (Non-Skid Ahhesive, NSA) or M/s Ardex Endura (Gold Star) or other approved equivalent, jointed with cement slurry & grouted with pigment of matching shade & finishing the top of skirting/dado etc. complete. |
| 63 | Providing & laying machine cut machine polished natural stones for repalcement of existing damaged stone in frames, kitchen platforms, cill, jambs, Facia etc including necessary cement mortar for backing/ bedding, araldite adhesive, close jointed and grouted with matching cement slurry and finished to line, slope, level, plumb, curing etc, as required including cutting of stone slabs, wastages, making cut outs wherever required etc all as per specifications and as directed by the Engineer in charge. (Cut size of stone will be measured) |
| 64 | 25 to 30 mm thick cuddappa stone single side polished |
| 65 | 25 to 30 mm thick cuddappa stone both side polished including rubbing and polishing the exposed edges. |
| 66 | Horizontal beading of size 30x16mm machine cut machine polished cuddappa stone |
| 67 | Mirror polished machine cut 16/18 mm thick Jet black Granite stone |
| 68 | horizontal beading of size 30x16mm machine cut machine polished Jet black Granite stone |
| 69 | 16/18 mm thick machine cut and single side machine polished Baroda green marble stone / Pink marble stone |
| 70 | Supplying, fabricating and fixing in position at all floors factory made Aluminium sliding/top hung/fixed/ adjustable louvered windows & ventilators with rivit joint of specified size, made of integrated bronze anodised matt finished (15micron thick) aluminium section (extruded) of Deluxe domal series or equivalent or as directed by EIC , including making exhaust fan frame work, handles of specified size etc, of approved manufacturers for following types with extruded sections of required series as per drawing of Jindal / Indal / Aluminax or other approved equivalent make of approved sections with size and weights as directed for frames and shutters(including wastages if any) conforming to relevant IS specifications with all approved Bronze anodised aluminium fittings and accessories, latching fixture, 2/3 rollers with ball bearing of superior quality all as shown in the drawing including providing and fixing aluminium channel beading/glazing clips fixed with necessary bronze anodised screws, grouting the gap with sealant and including dismantling of existing window frame and shutter, glass and depositing same to dept store etc all complete generally as per drawing, specifications etc, all as directed by EIC. |
| 71 | Providing & fixing ordinary plain / frosted / Bajara sheet glass/ for MS openable/louvers or aluminium sliding windows , glass doors, vision panels etc of approved make of following thickness in various sizes as required at site, using first class glass oil putty of approved quality and make including supplying & fixing glazing pins, teak wood or aluminium beading, EPDM gasket etc with necessary screws, nails etc (as required), at all floors & locations including cutting the glass to required size, removing the existing broken / damaged glass panes from windows / doors / partitions etc. along with its old oil putty/gasket /beading etc. carefully and disposing off the un-serviceable material with in colony including wastage in cutting, transportation etc. complete all as directed by the Engineer-in-Charge. |
| 72 | a) 4 mm thick plain glass for window panes |
| 73 | a) 5 mm thick clear float glass |
| 74 | b) 5 mm thick Bajra sheet glass |
| 75 | c) 3 mm thick Bajra sheet glass for louvers |
| 76 | Providing and fabricating and fixing in position structural steel grills at all level, using M.S. angles, flats, bars etc. with anchor fasteners of suitable dia in the marble jambs & cills including painting by dipping with two coats of synthetic enamel paint of approved shade & make and one coat of approved steel primer, including cutting,fabrication, welding etc complete all as per specification and as directed by the Engineer in charge. |
| 77 | Supplying & fixing 25 mm thick PVC integral free foam sheet in form of flush finish door shutter, manufactured by M/s. Jain Irrigation Systems Ltd. (Ex-cel sheet) / M/s. Rajashree plastiwood or other equivalent approved make of white colour, solid section, extruded rigid, light weight sheet with fine & homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides including providing recessions for hinges and providing & fixing 3 nos 100 mm heavy duty S.S. hinges and 2 Nos. 100 mm heavy duty aluminium baby latches, 2 nos. of 100 mm Al. Bow handles with back plate of M/s Shalimar Hardware or equivalent and including providing a vision panel opening of size 300 mm X 200 mm including providing and fixing PVC moulded louvers on both faces in the opening of vision panel with ss screws, all edges to be smooth finish with mixture of PVC powder & solvent etc complete all as per specification and as directed by the EIC.Note:- 1) The entire door shall be jointless shutter.2) The sizes shall be approximately 650 mm x 2000mm, however exact dimensions shall be measured at site before manufacturing. |
| 78 | Providing marine ply of 19 mm thick conforming to latest IS -710, for making / repairing of wooden cupboards/cabinet etc at all floors and levels, including cutting to required sizes and jointing and fixing the same with necessary screws, adhesives, providing and fixing teak wood lipping to all exposed faces of ply wood and including wastsge, transportation and including removing old damaged cupboards/cabinet and refixing the same after repair, including removing & refixing all fittings & fixtures and depositing unserviceable cupboards to departmental store etc complete all as per specifications and as directed by the Engineer in charge. |
| 79 | Supplying and fixing following type of fittings, fixtures and fastenings of approved quality along with necessary CP brass screws, bolts, nuts, washers and other standard accessories etc. complete all as directed by the EIC. |
| 80 | SS Piano hinges overall width of 35 mm |
| 81 | SS Piano hinges overall width of 19 mm |
| 82 | Supplying & fixing night latches of Godrej make or other equivalent approved make with 7 lever and with triplicate keys to the existing main door at various flat/ locations including all charges, screws, removing and returning the old fittings to dept. stores, shifting the positioning of night latch sets, if required and plugging the unwanted holes/ cut outs in door frame/ shutter etc. complete all as directed by the E-I-C. |
| 83 | Supplying & fixing in position the following type solid core block board flush door shutters with commercial ply / teak veneer as specified below conforming to IS 2202-latest, with 20 mm thick teak wood lipping alround, fixing shutters in position to existing door frames at all floors by cutting/ planing if necessary including the labour for removing & refixing old fittings & fixtures and for fixing of the fittings & fixtures with wooden packing pieces if necessary with screws, including one coat of approved primer on commercial ply surface etc.including removing existing damaged shutter,fittings and depositing at dept. stores etc. complete all as per specification & as directed by EIC. |
| 84 | a) For Door 32 mm thick commercial ply on both sides |
| 85 | b) For Door 38 mm thick commercial ply on both sides |
| 86 | Maintenance of door shutter without removing from position including removing & re-fixing of fittings / fixtures complete all as per specification & as directed by EIC. |
| 87 | Loosening and providing temporary supports to existing electrical fittings/ fixtures/ board for carrying out tiling work etc. and refixing it after completion of renovation including supplying & fixing casing capping & electrical wire wherever required as per deptt. specification etc complete all as directed by the EIC.Note: Measurement shall be for each fittings/ fixtures/ board. |
| 88 | Removing & refixing existing geyser with fittings & fixtures for carrying out tiling work etc.and refixing it after completion including supplying & fixing casing capping & electrical wire wherever required as per deptt. specifications etc complete all as directed by the EIC |
| 89 | Half brick masonry in partition walls using well burnt locally available bricks of approved quality in cement mortar 1:4 (Using factory made Ready Mix Mortar only) at all floors and levels, scaffolding, raking out joints, curing, etc. complete all as per specifications & as directed by the Engineer-in-Charge. |
| 90 | Providing & fixing IInd class teak wood in frames of required sections for doors, windows, ventilators, shaft doors, partition etc. wrought framed and fixed in position including providing & fixing necessary SS Screws and fixing frame in position including applying two coats of synthetic enamel paint of approved make and shade over a coat of approved wood primer for the exposed surfaces & two coats of bituminous paint to the surfaces of frames in contact with masonry / concrete etc. including removing the old damaged frames stacking serviceable material and disposing of debris inside Anushaktinagar colony at the location identified by EIC etc. complete all as directed by the EIC. |
| 91 | Supplying & fixing 10/18mm thick PVC integral free foam sheet in form of flush finish door shutter, manufactured by M/s. Jain Irrigation Systems Ltd. (Ex-cel sheet)/ M/s. Rajashree Plastiwood or other equivalent approved make of white colour, solid section, extruded rigid, light weight sheet with fine & homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides, all edges to be smooth finish with mixture of PVC powder & solvent etc including dismantling the existing plywood/A.C sheet shutters, removing and refixing of architraves with necessary screws, stacking serviceable material and disposing off debris inside Anushaktinagar colony at the location identified by EIC etc. complete all as per specifications and as directed by the EIC. Note: The entire shutter shall be jointless shutter. |
| 92 | a) 10 mm Thick |
| 93 | b) 18 mm Thick |
| 94 | Supplying & fixing matt finished, anodised aluminium heavy quality fittings, fixtures and fastenings of approved quality, along with CP brass screws, bolts and other accessories as per approved samples. complete all as per specifications and as directed by Engineer-in-charge |
| 95 | a) Baby latch 75 mm long x 12 mm barrel bolt |
| 96 | b) Handle 100 mm long |
| 97 | Providing and fixing fly proof stainless steel 304 grade wire mesh of 28 gauge(made out of 28 gauge wire) in the aluminium sliding door / window and clear story window, using wire gauge with average width of aperture 1.4 mm in both directions including providing and fixing of stainless steel screws and washer at maximum distance of 300 mm complete all as directed by Engineer-In-Charge. |
| 98 | Plain cement concrete 1:2:4 using graded stone aggregate of 20mm max. size at all levels and locations including mixing, laying, consolidation, finishing, curing, formwork including removing the existing flooring, finish and disposing off debris inside Anushaktinagar colony at the location identified by EIC etc. complete all as per specifications and as directed by the Engineer-in-Charge. |
| 99 | Supplying and fixing heavy duty superior quality fittings , fixtures and fasteners along with necessary CP screws, bolts, nuts, washers etc. as per approved samples. etc. complete all as directed by the E-I-C., |
| 100 | Providing and fixing 1.0 mm thick decorative laminated sheet of plain /wood grain in gloss / matt finish of approved make with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS:2046 Type S, including cost of adhesive of approved quality,removing and refixing door shutter, cutting, including cutting the shutters at bottom portion as per site condition ,wastage including disposal of debris outside colony etc complete all as per specifications and as directed by the EIC. |
| 101 | Providing & Fixing in position 25 mm commercial block board shutters forcupboard, kitchen cabinet etc. bonded withphenolformaldihyde resin shutter ofapproved manufacture with second class teak wood lipping of size 25mm wide and20mm thick alround for cupboard fixing to(frames will be paid under relevant item)including providing second claass teak wood meeting styles of size 25 x25mm shape asshown in the drawing by cutting/planning ifnecessary including labour charges for fixingthe fittings and fixtures (cost of fittings &fixtures will be paid under relevant item)and if required painting all over with two coats ofsynthetic enamel paint over a coat ofapproved primer all complete as perspecifications, drawings and as directed byEngineer-in-Charge. |
| 102 | Repairs to the existing door frame by replacing part of the frame with 2nd class teak wood at site of work by :i) Cutting of the damaged / decayed portion of the door frame without disturbing / removing of the existing frame. ii) Providing wood with 2nd class teak wood as per the existing frame for repairing of the damaged / decayed portion of the frame including making lap joints for jointing the new wood with old wood work by fixing necessary screws and synthetic adhesive etc. complete. iii) Fixing the repaired door frame in position with embedding the frame upto 50 mm depth in the floor and fixing coach screws to the wall including breaking of the floor for making pocket, applying two coats of bituminous paint to the surfaces of frames in contact with masonry /concrete, repairing floor with P.C.C. 1:2:4 finishing, including one coat of synthetic enamel paint over one coat of primer on new work and one coat of synthetic enamel paint over entire surfaces of frame etc. & disposing of debris with in colony etc. complete all as directed by the Engineer-in-Charge. |
| 103 | Providing and fixing C.P. teak wood moulded beading 40x20 mm(architrave) size mentioned below around door & window frames at all floors & locations with necessary screws including two coats of painting with one coat of approved primer including cost of screws, wastages in cutting, transportation etc. including removing the old damaged beading and disposing the same complete all as directed by the Engineer-in-Charge. |
| 104 | Labour charges for Removing, dismantling, fabrication & refixing existing Aluminium sliding/top hung/fixed/ adjustable louvered windows & ventilators/doors with rivet joint of specified size along with MS safety grills, window for repair & maintenance such as replacement of rollers, marble cills, jams, EPDM Gasket, sealent all complete generally as per specifications , all as directed by EIC. (Rollers, gasket, friction hinges, marble stone, floor springs etc shall be paid under relevant item.) |
| 105 | Labour Charges for cleaning, brooming, washing/mopping the vacant flats including disposing of waste materials including cost of cleaning materials like brooms, detergents/disinfectants etc complete all as directed by the Engineer-in- Charge. |
| 106 | a) Upto Type III C including transit/efficiency flats |
| 107 | b) Type IV D & Above flats |
| 108 | Carrying out miscellaneous welding work at all levels & location for MS windows, ladders, fencing, gate etc including required peg stay, cleat, louver cleat, hinges, member, hook, bolt, nut other required materials, labour, welding machine, welding rod etc complete all as per specifications & as directed by the EIC. |
| 109 | Supplying & fixing of Nylon rope (Cloth Hanger purpose) 6 mm dia as directed by the EIC |
| 110 | Supplying & fixing of MS Safety chain for doors complete all as directed |
| 111 | Sand faced cement plaster 20 mm thick in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnical mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 12 mm thick and finishing coat of 8 mm thick final rendering,including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, including membrane curing by applying one coat of factory made curing compound Resikure of M/s Anuvi Chemicals, Concure of M/s fosroc, Dr. Fixit curing compound or other equivalent over repaired surfaces as per manufacturer's specification etc. including removing existing damaged/ worn out plastering and disposing off debris inside colony etc. complete all as per specifications & as directed by the Engineer-in-charge.NOTE:1.The contractor must take full precautions that original brick work is not damaged while dismantling of plaster. Incase of any damage the same shall be made good with 22g chickenwire mesh at his own cost . No separate payment for any additional thickness of plaster if any will be made. Contractor must visit site and acquiant himself with the condition of building. |
| 112 | Pressure grouting through RCC slab / brick masonry by drilling hole in RCC slab to required depth without causing any damaged to reinforcement, inserting ½” dia PVC pipe in hole securing the hole sides with mortar 1:2, pressure grouting with cement slurry mixed with approved water proofing compound @ 2% by weight of cement to required pressure, continuing the pressure grouting till the flow of cement slurry stops, removing the PVC pipe, sealing the hole with cement mortar 1:1, scaffolding etc. complete all as directed by the Engineer – in – Charge. |
| 113 | White washing for ceiling & walls of rooms and staircases in two coats on old works with lime of approved quality by adding blue and glue in required quantity including scaffolding, scrapping, wherever required,cleaning the surface with sand paper and fibre broom and filling the cracks, holes, with approved putty and making even surfaces etc. complete as per specifications including cleaning of floors, doors, windows etc. as directed by the Engineer-in-Charge. |
| 114 | Providing and applying one coat of cement based grey putty of M/s Roofit mix or other approved euivalent make over entire surface including preparing old painted surfaces by thoroughly scrapping oil bound distemper /acrylic emulsion / white wash etc, filling up the cracks, crevices, depression, holes, spray curing for three day etc, including sand papering and making surfaces even and smooth dusting /cleaning, scaffolding , covering the furniture etc with tarpaulins or eqivalent covering materials, cleaning of all surfaces etc.& disposing of debris inside colony at designated location etc.complete as per specifications and as directed by the Engineer-in-Charge. |
| 115 | Repainting of old painted surfaces with two coats synthetic oil bound distemper of approved shade and make over one coat of approved cement primer, including thoroughly scrapping, removal of old paint if any, sand papering & preparing the surfaces, applying approved stucco putty to entire surface to fill up crevices mild depression etc. scaffolding including cleaning of floors, doors & windows etc.& disposing of debris in side colony at designated location etc. all as per specifications and as directed by the Engineer-in-Charge. |
| 116 | Repainting of old painted surfaces with two coats FLAT oil paint of approved shade and make over one coat of approved cement primer, including thoroughly scrapping, removal of old paint if any, sand papering & preparing the surfaces, applying approved stucco putty to entire surface to filling up crevices, mild depression etc. scaffolding including cleaning of floors, doors & windows etc.& disposing of debris inside colony at designated location etc. all as per specifications and as directed by the EIC. |
| 117 | Repainting of old painted surfaces with two coats of acrylic emulsion paint of approved make & shade over two coats ofapproved primer (alkali resistant) consist of thoroughly scrapping oil bound distemper /acrylic emulsion / white wash surface, applying a coat of approved cement primer, filling up the cracks with approved crack filling compound , applying approved stucco putty to entire surface to fill up crevices, mild depression etc. thoroughly scrapping the surface, applying 2nd coat of approved cement primer carrying out full stucco puttywork , apply two coats of acrylic emulsion paint including necessary covering material and removal of splashing & droppings from floors, walls including scaffolding, ladder as required & disposing of debris in side colony at designated location etc. complete all as directed by the Engineer-in-Charge. |
| 118 | Repainting of old painted wooden/steel surfaces with two coats of synthetic enamel paint using first quality synthetic enamel paint of approved make and shade over one coat of approved wood/steel primer including preparing surfaces, filling with putty scaffolding and cleaning etc. including removing old paint by scrapping, blowlamp etc.complete all as directed by the EIC. |
| 119 | Providing and applying three finished coats of exterior grade acrylic based emulsion (Over sand faced plastered surfaces / RCC Jalli / fins ) of Apex Ultima of M/s. Asian Paints / Excel of M/s. Nerolac / Heatshield of M/s. Dr.FIXIT / Weathershield Max of M/s. ICI Delux or other approved equivalent make and shade over the sand face / rough cast plaster/ RCC jalli / RCC fins at locations as required, including preparation in proportion of One litre of Apex Ultima or other makes with 400 ML. of potable water, thoroughly mixed and applied at an interval of 4-6 hours for each successive coats and ensure consumption of 0.27 ltr/Sqm for 3 coats, including scaffoliding ,preparation of surface, cleaning and filling the cracks and crevices with Latex caulking crack filler etc. complete generally as per the manufacturer's specification and as directed by the EIC. |
| 120 | Repainting of old painted surfaces with two coats of Royal luxary acrylic emulsion paint of approved make & shade over two coats of approved primer (alkali resistant) consist of thoroughly scrapping oil bound distemper /acrylic emulsion / white wash surface, applying a coat of approved cement primer, filling up the cracks with approved crack filling compound , applying approved stucco putty to entire surface to fill up crevices, mild depression etc. thoroughly scrapping the surface, applying 2nd coat of approved cement primer carrying out full stucco puttywork , apply two coats of acrylic emulsion paint including necessary covering material and removal of splashing & droppings from floors, walls including scaffolding, ladder as required & disposing of debris in side colony at designated location etc. complete all as directed by the Engineer-in-Charge. |
| 121 | Applying three coats of Touch wood of approved make & tint to obtain finish as required over a coat of wood filler including sand papering, cleaning, filling up holes, cracks & crevices with putty etc. complete to give an uniform shade etc., complete all as per specifications & as directed by the Engineer-in-Charge. |
| 122 | Providing and fixing Godrej or other equivalent multipurpose lock for doors of shelves/nitches/cupboards/cabinets with stainless steel duplicate keys including removing old non functioning existing lock and depositing to deptt. Stores, etc complete all as per specification and as directed by the E-I-Charge. |
| 123 | Supplying and fixing following type of miscellaneous fittings, fixtures and fastenings of approved quality Stainless steel fittings and fixtures of M/s Shalimar hardware or approved equivalent along with necessary CP brass screws,bolts, nuts, washers and other standard accessories as per approved sample etc. complete all as directed by the Engineer-in-charge |
| 124 | a) Heavy duty SS 304 butt hinges of size 125mm X 76mm X 2.8 mm |
| 125 | a) Heavy duty SS 304 butt hinges of size 75mm X 50mm X 1.7 mm |
| 126 | Heavy quality magic eye / door viewer of brass body, having minimum 180 degree wide angle lens suitable for flush door of thickness 35mm to 50 mm, total length closed condition 40 mm, inside dia 25 mm, mounting diameter 14 mm having full thread for length adjustment |
| 127 | SS Aldrop(SS-304) 250 mm long , 16 mm dia Barrel. with extra locking arrangement of M/s Shalimar (ISI marked) |
| 128 | Supplying & fixing heavy duty superior quality matt finished anodised (anodic coating not less than Grade AC10 as per IS 1868) ISI marked aluminium fittings and fixtures and fasteners along with necessary CP screws, bolts, nuts, washers etc. as per approved makes etc.complete all as directed by the Engineer-in-chargeNote: A sample of each material listed should be got approved by Engineer-in-Charge before supply. |
| 129 | Bow Handle 100 mm. long with back plate, ' D ' section. |
| 130 | Tower bolt 200 mm long with 10 mm dia barrel |
| 131 | Tower bolt 150 mm long with 10 mm dia barrel |
| 132 | Superior Quality Aluminium door stopper Floor type with heavy quality rubber bush fixed with screw, complete set. The weight of aluminium door stopper without rubber bush and screw shall not be less than 25 gms each. |
| 133 | Aluminium door Latch/Tadi having sixe 250 mm x 60 mm x 40 mm with hole for locking arrangerment of approved sample |
| 134 | Heavy duty 100 mm long concealed sliding window zinc body lock (Star lock or approved equivalent) |
| 135 | Heavy duty 150 mm long concealed sliding window zinc body lock with L and Key (Star lock or approved equivalent) |
| 136 | Heavy duty 200 mm long Domal series concealed sliding window zinc body lock with L and key (Star lock or approved equivalent) |
| 137 | Heavy duty 250 mm long Domal series concealed sliding window zinc body lock with L and key (Star lock or approved equivalent) |
| 138 | Heavy Quality PVC roller for alluminum sliding windows |
| 139 | EPDM Gasket for existing Aluminium window. |
| 140 | Supplying & fixing matt finished, anodised aluminium heavy quality fittings, fixtures and fastenings of approved quality, along with CP brass screws, bolts and other accessories as per approved samples etc. complete all as per specifications and as directed by Engineer- in- Charge. |
| 141 | a) Tower bolt 150 mm long with 10 mm dia. barrel. |
| 142 | b) Bow Handle 100 mm long 10 mm dia. Solid. |
| 143 | c) Heavy duty Harsp stable 150 mm long(For locking arrengement) |
| 144 | d) Magnetic catch |
| 145 | Removing & Refixing of existing cupboard door shutter with frame including fixing of necessary arrangement like nailing, screwing etc.inclusive Reparing/ change of any broken wooden batton with existing matching, filling with putty and painting of two coats synthetic enamel paint of approved make including all the fixing arrangement as specification & as directed by EIC |
| 146 | Providing & applying asian paint smartcare Damp block white colored coating over wall / concrete surface including cost of removing existing old paint with putty etc., applying one coat of self priming coat of AP smart care damp block (diluted with water in 1:1 ratio) and applying two coats of AP smart care damp block (diluted with water in 3:1 ratio) etc. complete as per specification & as directed by the EIC |
| 147 | Providing and fixing adustable M S Tubulor props up to 4.00 M at required locations including breaking loose conrete/plaster, including cost of supporting planks, wooded members etc. as per drawing/ sketch, complete all as directed by the Engineer-in-charge. |
| 148 | Removing & refixing exisiting door shutters in original condition after completion of repairing works of frames including all labours and all the fittings and fixtures etc. complete all as per specifiction and as directed by EIC |
| 149 | Providing centring shuttering Form Work using 19 mm PVC film faced plywood to get neat form finish surface for Walls, partitions, paradi and the like including attached pilasters etc.as per drawings, specifications and as directed by the Engineer-in-Charge. |
| 150 | Removing of loose plaster from ceiling, cheking the nearby surface by wooden mallet, covering of furniture/households in the area of work, providing wooden/MS propes, disposal of debries at the nearby dumping yard inside colony, including scaffolding etc, complete all as directed by the Engineer-in-charge. (Damaged loose plaster will be measured for payment) |
| 151 | Providing and applying white cement based putty of average thickness 3 mm on ceiling to prepare the surface even and smooth, of approved brand and manufacturer including nesssary scaffolding etc, complete all as per manufacturer’s specifications. etc. and as directed by the Engineer-in-charge. |
| 152 | Repairs to damaged RCC structural members at all locations/ floors using polymer modified cementatious mortar, for strengthening the existing RCC structural members using acrylic based polymer and comprising the following operations: 1. Breaking cracked / spalled concrete members along the cracks with plaster, including removing and stacking of all unserviceable material at site,simultaneous transportation and disposed at a location in Anushaktinagar as identified by EIC. complete all as per specifications and as directed by the Engineer-in Charge.2. Exposing and cleaning the reinforcement thoroughly by light tapping / wire brushing of using strong emery paper and finally by acetone /rust remover of Dr. Fixit / Anuvi chemicals / Fosroc or other eqivalent.3. Applying a coat of polymer and cement slurry in the ratio 1:1 by volume to the reinforcement bars.4. Polymer required for the work shall be procured by the Agency from approved Manufacturers Like M/s Astra , M/s Anuvi, M/s Apcotex or other approved equivalent manufacturer confirming to technical requirements as below and the invoices/challans etc to be submitted to EIC for record. Appearance: Milky white Ph- value : 9-10 Specific gravity : 1.055+/-0.005 Solid contents(%w/w)-: 44+/-1 Viscocity at 25 degree C temperature (in sec): 15-20 Testing of the material as per relevant codes at NABL approved third party Lab. is to be done by the Agency for every batch/lot of supply.5. Bond coat should be applied @ 0.37 ltr./layer/sq.m.6. Minimum FM of silica sand should be 2.10 |
| 153 | a) Building up with polymer modified cementatious mortar for RCC structural members etc. in layers not exceeding 20 mm in a day (proportion – cement 50 Kg. : Silica sand 125 Kg. : polymer liquid 10 ltrs.) with necessary bond coat (polymer : Cement = 1:1 by volume) for tack coat and also for subsequent layers using polymer including curing, covering the flooring /window with tarpaulins or equivalent covering material to avoid deposition of polymer mortar and cleaning of floor / windows thoroughly on completion of repair work etc. complete all as per specifications and as directed by the Engineer-in-charge. Polymer used for this work in KG shall be measured for payment. |
| 154 | b) Repairing with polymer bonded mortar up to 35mm thick in layers of not exceeding 20mm (with out chicken mesh) in a day (proportion- cement 50 Kg : silica sand 125 Kg) with applying protection coat / bond coat to reinforcement, bond coat to old concrete and bond coat for every successive layers of 20mm thick in proportion polymer : Cement-1:1 by volume as per specification including covering the floor/windows with tarpaulin or equivalent covering material etc., and cleaning after repair etc., complete all as per specifications and as directed by the Engineer in charge. The rate is inclusive of supplying and applying protection coat /Bond coat of polymer. |
| 155 | Reinforcement for reinforced cement concrete conforming to IS at all floors & levels including, supplying, cutting, bending, fixing and tying in position with 1.6 mm dia soft drawn annealed binding wire including cost of binding wire, labour etc. complete all as per specifications and as directed by the Engineer-in-Charge. Note: Binding wire required for the work shall be supplied by the contractor & the same will not be measured for payment. |
| 156 | a) With high yield strength deformed bars Fe 500 grade |
| 157 | Providing and applying shrinkage crack filler of Dr. Fixit Crack X Paste or other equaivalant material including opening the loose part of the existing crack , making the same in V - shape in required depth & width, cleaning the groove by removing dust, oil, grass, loose particals etc., press the crack filler in to the crack one time only with a spatula or putty knite and level the surface etc. completed all as per manufacturer's specifications and as per direction of the engineer-in-charge. |
| 158 | Cement plastering using factory manufactured pre mix/ready mix mortar in CM 1:4 of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnical mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied on internal wall and ceiling finished smooth with POP over brick walls or concrete surfaces at all floors and levels, including membrane curing by applying one coat of factory made curing compound Resikure of M/s Anuvi Chemicals, Concure of M/s fosroc, Dr. Fixit curing compound or other equivalent over repaired surfaces as per manufacturer's specification and removing existing damaged/ worn out plastering and disposing off debris inside Anushaktinagar colony at the location identified by EIC etc. complete all as per specifications and as directed by EIC. |
| 159 | a) 6 mm thick |
| 160 | a) 12 mm thick |
| 161 | b) 15 mm thick. |
| 162 | Filling of joints of tiles, stone using white cement, grey cement etc including cleaning the area etc. complete all as per specifications and as directed by the Engineer-in-charge |
| 163 | Providing and fixing heavy quality MS peg stay having size matching with existing window shutter with necessary screws etc. complete all as directed. |
| 164 | Providing and injecting chemical emulsion for post construction anti-termite treatment and creating a chemical barrier under all round walls, floors, wooden surfaces, junction of walls & floors, beams, columns etc. complete with using chloropyriphos 20 EC / Linden 20 E.C or approved equivalent termiticide emulsion conforming to IS and approved by the Insecticide Regulation Act Authority with proportion 1 part chemical and 19 part water or as per the manufacturer's specification and also the injecting chemical formulations should be as per I.S. 6313 part III 1971 specification and as approved by the insecticide Regulation Act. including drilling holes 12 mm dia 300 mm centre to centre or as close as possible and scaling the same hole after injection of the chemical emulsion with cement mortar 1:3, (1 part cement : 3 part cement ) without causing any damage to the materials like wooden furniture electric fittings and any other materials including spraying to the entire affected area with the same chemical formulation etc. complete all as per specifications and as directed by the Engineer in charge. NOTE :- 1.The inspection & anti-termite treatment shall be carried out in the affected premises for as many times as necessary for complete extermination of white ants.2. Care should be taken by contractor to ensure that pets & human beings are not affected on account of the above treatment.3. After satisfactory completion of anti- termite treatment the payment shall be made to contractor for the actual quantum of work done.4. Appointment from the allottee to be taken before starting the treatment and the number of flats should be intimated for which appointment for the particular date is taken.5. Above treatment shall be guaranteed for one (1) year from the date of compeltion of work. The guarantee shall be given on the regular format of the Department under Conditions of Contract. 6. Wherever treatment is required to be given to wood work doors etc. the chemical to be prepared in Kerosene instead of water all as per IS specification. |
| 165 | a) Upto Type III C including transit/efficiency flats |
| 166 | b) Type IV D & Above flats |
| 167 | Attending carpenatry related works in vacant flats by checking, repairing, refixing/ replacing woods/ aluminium / brass fittings & fixtures, making all doors of the flat functional, making all sliding windows & louver windows functional including fixing of rollers for windows and screws required for carpenatry work etc. complete all as directed by the Engineer in Charge. |
| 168 | PART II - PUBLIC HEALTH WORKS |
| 169 | Providing and fixing EWC closet suit comprising : a)European water closet with 'P' or 'S' trap similar to Model- Slick of M/s Hindware (Cat No. 20011) make Sanitary ware in white glazed vitreous chinaware b) Solid plastic heavy quality seat with lid similar to M/s. Hindware or approved equivalent and including cost of removing the existing one & disposing of debris inside Anushaktinagar colony at the location identified by EIC etc complete all as per specification and as directed by the EIC. |
| 170 | Providing & fixing EWC floor mounted with integrated ceramic cistern, Ecoflush Deluxe Omni suit model of JOHNSON or equivalent model similar in all features from M/s. CERA, Hindware, Parryware etc, with 'S' or 'p' trap European water closet in white glazed vitreous Chinaware including cost of removing the existing one and depositing serviceable material at dept store & disposing of debris out side colony including providing & fixing heavy quality PVC inlet connection with brass unions at ends and necessary outlet connections required . |
| 171 | Providing & fixing approved WHITE Orissa pattern W.C. of M/s. Hindware make model no 20042 (ECO)/20070 (COMFORT) or approved equivalent with 'P' or 'S' trap in white glazed vitreous china ware of size 580 mm x 440 mm conforming to IS, including the cost of removing the existing damaged / broken and making good the surrounding with cement mortar / concrete to the existing finish & disposing of debris inside Anushaktinagar colony at the location identified by EIC etc complete all as per specifications and as directed by the EIC. NOTE: In case of non availibility, other approved make as mentioned in 'Specification for Public Health Engineering Works' may be considered. |
| 172 | Providing and fixing Universal water closet suit comprising : a)Universal water closet with 'P' or 'S' trap similar to Model- Slick of M/s Hindware (Cat No. 20012) make Sanitary ware in white glazed vitreous chinaware b) Solid plastic heavy quality seat with lid similar to M/s. Hindware or approved equivalent and including cost of removing the existing one & disposing of debris inside Anushaktinagar colony at the location identified by EIC etc complete all as per specification and as directed by the EIC. |
| 173 | Providing & fixing approved quality wash basin of M/s Hindware or other approved equivalant in white glazed vitreous chinaware supported on suitable wall brackets and of size mentioned below, including providing & fixing Jaquar Cat No. 705/709 CP brass waste coupling, including cost of removing the existing wash basin and fittings such as piller cock, inlet connection, stop cock, waste coupling, bottle trap etc.depositing serviceable material at dept store & disposing of debrisinside Anushaktinagar colony at the location identified by EIC etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 174 | 550 mm x 400 mm ( Approx Size ) MARIO Cat No. 10087 |
| 175 | 460 mm x 330 mm. ( Approx Size ) DUNE Cat No. 10088 |
| 176 | Under counter oval shape wash basin of size 560X410 |
| 177 | Providing & fixing approved quality One piece EWC with Calibre premium Seat cover with Twin flushing system of M/s Cera Sanitary ware or other approved equivalant in Snow white glazed vitreous chinaware including all fixing accessories,white cement & including cost of removing the existing one & disposing of debris out side colony etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 178 | Calibre 660x360x760mm P Trap One Piece EWC with Calibre Premium Seat Cover and Twin Flush fitting Snow White (Cera Cat no.S1013147 Or Equivalent) |
| 179 | Providing & fixing good quality SS floor grating (Jali) in bath & toilet including fixing the jali with white cement matching the floor level etc. complete as per specification, drawings and as directed by EIC. |
| 180 | Providing & fixing approved C.P. brass towel rods of size 600 mm x 20 mm with a pair of C.P. brass brackets, wall flanges etc. fixed to wall with C.P. brass screws, screwed on to rawl plugs etc complete including the cost of removing the existing one & returning to Stores etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 181 | Providing & fixing approved heavy quality 15 mm dia inlet connection with unions at the ends plastic pipes with brass unions including the cost of removing the existing one etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 182 | a) size 600 mm long |
| 183 | b) size 450 mm long |
| 184 | Providing and fixing approved quality 10 Ltrs. capacity PVC flushing cistern of Hindware Sleek Fresh with odorizer slot having single flush white colour or approved equivalent with all internal non ferrous fittings, pull chain including P&F inlet PVC connectors of approved make and quality and outlet connections and wall mounted on brackets, including providing and fixing PVC flush pipe Everlas or equivalent of 32 / 40 mm dia. to a length 1.00 M (approximate) and connecting to the flush tank with proper check nut and connecting to the W.C. pan and making leak proof joints etc., including cost of making chases in the wall, floors, removing the existing one depositing to deptt. Stores etc.complete all as directed by the Engineer-in-Charge. |
| 185 | Supplying & Fixing Stainless steel Sink of following size of approved make, moulded out of 19 SWG (1 mm ) stainless steel sheet of grade AISI 304 (18/8) with waste coupling conforming to IS 13983, placing and fixing the Sink in position to correct line and level with basket type choke-stop strainer, waste coupling , Check nuts etc. including the cost of jointing materials, finishing the edges with white / matching colour cement as per manufacturer's recommendation all complete, including cost of all etc. as per specification and as directed by the Engineer-in-charge. |
| 186 | a) Supplying and Fixing Stainless steel Sink' Nirali-Grace Plain' with 'Anti scratch surface' of overall size 610 x 460 mm ( Bowl size 560x410x250 mm ) |
| 187 | Removing and refixing existing Stainless steel sink along with other accessories, including labour charges, cleaning, testing, including providing and fixing pvc waste pipe etc. Complete all as per specifications and as directed by E.I.C |
| 188 | Providing & fixing in position best quality bevelled edge plate Glass Mirror of size 500x350 mm / 600x450mm / 450x300 mm & 6mm thick with marine ply wood back 6 mm thick conforming to IS-710, CP brass cup screws and caps, washers etc. including providing & fixing rawl plug in wall, wooden packing behind the mirror if necessary, reinstating the damages to its original condition etc. and painting the ply with 2 coats of Synthetic enamel paint over a coat of wood primer etc. complete all as directed by the Engineer-in-Charge. |
| 189 | Providing & fixing in position approved quality CP brass Bib tap / Sink tap etc. of 15 mm nominal dia. with IS mark / approved make of following type including providing & fixing GI specials ,wall flanges and fixing to concealed / exposed CPVC / G.I.pipe line with leak proof threaded joints using spun yarn, white zinc etc., testing the joints, rectifying the leaky joints, if any, including cleaning etc. complete all as per specifications and as directed by Engineer- in- Charge. |
| 190 | b) C.P brass Bib tap with wall flange, .similar to 'Continental series ' of ' JAQUAR' Cat. No. 047 |
| 191 | c) C.P brass long body Bib tap 2 in 1 similar to . FLORENTINE Series' of ' JAQUAR' cat. No. 5041 including providing and 'fixing Health faucet with 1.0 mt long flexible tube and wall hook( JAQUAR make Cat. No. 573) |
| 192 | Providing & fixing in position 15 mm diameter CP brass Stop Cock / Angle cock confirming to IS / approved make fixing the cock in position with white zinc and spun yarn, testing the joints for leakage etc. all complete as per specifications and as directed by EIC |
| 193 | i) Angular Stop Cock with wall Flang similar to 'FLORENTINE Series' of ' JAQUAR' cat. No. 5053 |
| 194 | ii)Angular Stop Cock with wall Flang similar to ' Continental Series ' of 'JAQUAR' cat. No. 053 |
| 195 | Providing & fixing in position following size Bottle Trap of Jaquar Cat. No. 769 with C.P brass extension piece to wall C.P brass wall flanges etc. |
| 196 | a) size 32 mm |
| 197 | Providing & fixing in position 15 mm diameter CP brass Pillar Cock conforming to IS/approved make fixing the cock in position with inlet connection using white zinc and spun yarn testing the joints for leakage etc. complete all as per specifications and as directed by EIC. |
| 198 | a) C.P brass Pillar Cock 15 mm size having similar to 'Florentine' of 'JAQUAR' cat. No. 5011 |
| 199 | b) C.P brass Pillar Cock 15 mm size having similar to 'CONTINENTAL' of 'JAQUAR' cat. No. 011 |
| 200 | Providing & fixing in position approved quality CP brass Wall mixer, 15 mm nominal dia. with IS mark and / approved make of following type including providing & fixing wall flanges and fixing to concealed / exposed water supply pipe line with leak proof threaded joints using spun yarn, white zinc etc., testing the joints for leakage all as per specifications and as directed by EIC. |
| 201 | a ) Wall mixer with provision of over head Shower with 115 mm long bend pipe & wall flange similar to' 'FLORENTINE' of 'JAQUAR' cat. No.5273 |
| 202 | b) Wall mixer with provision of over head Shower with 115 mm long bend pipe & wall flange similar to 'CONTINENTAL' of 'JAQUAR' cat. No. 273 |
| 203 | Providing & fixing in position CP Brass / Matt Chrome approved quality Shower of following type, fixing it to GI pipe line including jointing with white zinc and spun yarn etc., testing the joints etc all complete all as per specifications and as directed by the Engineer-in-Charge. |
| 204 | a) C.P brass Rose Shower with revolving joint similar to OHS-CHR-1985 & shower arm light body with wall flange similar to SHA-CHR-477 M/s. JAQUAR' |
| 205 | b) C.P brass Shower single flow with revolving wall joint with shower arm 190 mm long light body with wall flange of 'CONTINENTAL Series 'of 'JAQUAR' cat. No.491 & 477 |
| 206 | Providing & fixing in position 550x100mm wide & 6 mm thick Glass shelf with brass brackets of approved quality and fixing the Glass shelf on the wall to proper line & level using wall brackets with 40 mm long CP brass screws including making the wall to it's original condition and moulding of edges of glass etc. all as per specification & as directed by EIC. |
| 207 | Providing & fixing on Exposed or concealed surfaces the following dia Chlorinated Polyvinyl Chloride (C-PVC) pipe of specified class of M/s. SUPREME / PRINCE/ M/s. Jain Irrigation/M/s. Ajay pipes or other approved equivalent consisting following items of work:-i) Supplying & fixing C-PVC pipes, including necessary all fittings conforming to IS 15778ii) Laying and fixing the pipe and specials on exposed or concealed surfaces to correct line, level and plumb for water supply line, overflow and vent using M.S. nails/screws, rawl plugs, wooden gutties and branded clamps of Supreme/Prince make to the pipeline as per the site requirement.iii) Testing the pipe line to a hydraulic pressure as per manufacturers cataglouge for leak proof joint or as per relavant codeiv) Making leak proof threaded / solvent joints. including cutting the pipe, Joint preparartion, cleaning, marking, application of solvent, assembling, curing etc. and the cost of jointing cement solvent materials.v) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. proof joints.vi) Providing and fixing C-PVC jointable / threaded fittings such as Union, Nipples, Bendes, Elbows, Tees, Reducers, End caps, Couplers, Adaptors, Saddles, Plugs, Tank connectors, Expansion loops, Bypass bends, etcvii) including removing existing GI pipe line with fittings and specials etc.Note:- All brass threaded elbows and fittings shall be with additional support type of M/s. Prince, Supreme or other equivalent approved by EIC including necessary fixing arrangement such as screws, plug etc complete. SDR 11 Pipes and Fittings ( Mode of measurement :- The measurement shall per Unit RM length of pipe line laid or fixed. The measurement shall be taken along centre line of pipe. No measurement shall be recorded saperately for fittings etc. ) |
| 208 | a) 15 mm n.b |
| 209 | b) 20 mm n.b |
| 210 | c) 25 mm n.b |
| 211 | Providing, laying, jointing, fixing & painting heavy quality (Class 'C') M.S. Galvanized pipes as per I.S. 1239-1968 including fittings like elbows, collars, tees, unions, couplings, reducers, enlargers, bends and all other fittings required for the completion except screwed flanges conforming to I.S. 1239-1968 & also as per the code of practice of water supply in bldgs. Of I.S. 2065-1972 including laying under floors, chasing, in walls, roof slabs and making good the same to the original conditions, including the cost of all jointing materials like hemp yarn, white or red lead, clamps, wooden gutties, screws, cement, sand etc. including painting the pipe with coats of synthetic enamel paint over a coat of Primer & wrapping hessian cloth in concealed portion including removing the old damaged G.I. Pipes & handing over to Deptt. Stores, scaffolding, testing the pipes etc. complete all as per specifications and as directions of the EIC. |
| 212 | a) 15mm dia. |
| 213 | Supplying and fixing following size PVC-SWR pipes and Fittings for soil, waste,vent and rainwater pipe lines consisting following items of work:-i) Supplying PVC - SWR pipes and fittings conforming to IS 13592 of approved make and standard PVC clamps ( approx. 3.2 mm thick ) and nails or MS galvanised clamps having minimum 3 mm thick for fixing the pipe.ii) Fixing the pipeline vertically to plumb, keeping the pipe barrel 50 mm away from the wall face, using PVC or MS galvanised clamps Including scaffolding.iii) Providing and fixing PVC Domed roof outlet (grating ) for RWP & PVC cowl for waste / soil pipe.iv) Jointing the PVC pipes and specials by PVC solvent cement, rubber lubricant with rubber rings or any other approved equivalent method.v) Laying the pipeline below the ground to proper slope and gradient for making connection of soil and vent pipeline ( Vertical stacks ) with inspection chamber or manhole and waste water pipeline with gully trap chamber including the cost of cement mortar, water proofing compound etc., testing the vertical pipeline by smoke test and horizontal pipeline by 600 mm head of water and rectifying the leakages, if any all complete .vi) Cutting or making hole in RCC or brick work and reinstating the surface to it's original condition after passing the pipe with cement mortar / cement concrete etc. by adding approved water proofing compound. PVC - SWR Pipe & Fittings ( TYPE-B ) |
| 214 | a) 75 mm dia. |
| 215 | b) 110 mm dia. |
| 216 | Providing & fixing SWR PVC Nahani trap of self cleaning design with 75 mm outlet having a minimum water seal of 50 mm with S.S. Grating on top including necessary 1:2:4 cement concrete for embedding the trap etc. complete conforming to relevent I.S. including removing the existing one & depositing to Dept. stores etc. complete all as per specifications and as directed by the Engineer in charge. |
| 217 | Providing & fixing 125 mm dia S.S. grating for Nahani trap with necessary cement mortar 1:4 & matching cement and including removing existing grating, disposal of debris inside Anushaktinagar colony at the location identified by EIC etc complete all as per specifications and as directed by the Engineer in charge. |
| 218 | Labour charges only for carefully removing / dismantling the existing G.I. Water supply pipe line in all sizes, along with its existing fittings at all floors and location including cleaning the pipes with thin rod, removing sand particles or miscellaneous other obstructions in pipes and fittings including labour charges for replacing the damaged / unserviceable G.I. Pipes & fittings wherever found necessary including refixing the same in its original position in proper line, level and plumb with necessary specials / fittings making threading's, jointing the pipes and fittings with hemp yarn, white zinc paste, clamping, testing the pipes & fittings for leakproofness and smooth working including returning the defective / unserviceable materials to stores of maintenance Units etc. complete all as per specifications and as directed by the Engineer-in-Charge.NOTE: Necessary materials required for replacement shall be supplied by the deptt. free of cost. |
| 219 | Providing and fixing PVC flush pipe Everlas or equivalent of 32 mm dia up to a length of 2.25 M (approximate) and connecting to the flush tank with proper brass check nut and connecting to the W.C. pan and making leak proof joints of flush and W.C. ends and including removing the existing one etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 220 | Providing brick bat coba using 40 mm size graded brick aggregate in ready mix cement mortar 1: 4 for filling in sunken floor at all levels and locations, and finishing the surface even so as to be suitable to receive the water proof cement plaster etc. including curing, finishing and removing existing worn/ damaged plaster & disposing off debris etc complete all as per specifications and as directed by the Engineer in charge. |
| 221 | Providing cement based waterproofing treatment to the sunken floor of water closets, bath rooms, nahanis, washing places etc. giving injections to the concrete surface as required with cement and approved waterproofing compound solution to fill all inherent holes, voids, honey-combs etc. in the concrete, applying waterproof plaster of about 25 mm thick for the floor areas of the depression and about 18mm on the side walls of the depression and continue the vertical treatment on the walls above the proposed floor finish upto a height of 600 mm with surface suitable and even to receive tiles, including applying one coat of zycosil coating with (1 zycoil : 20 Water) solution testing the treatment for water tightness by impounding water for 7days etc. complete all as directed by the Engineer-in-Charge.Note :- i) The contractor shall furnish guarantee bond on appropriate stamp paper in the proforma as per Appendix 'D' for the entire waterproofing treatment for maintaining the surroundings and under side surfaces of the waterproofing treatment in bone dry condition for 5 years. During the guarantgee period the contractor shall attend all leakages, defects etc. if noticed, free of cost, starting the work of checking up and rectification within a week's time from the date of intimation about suchleakages / defects.ii) The measurement for payment shall be actual area covered by the treatment.iii) The waterproof brick bat coba filling coming over the waterproof plaster shall be measured in Cum separately and the cost of the same is not incuded in this item. |
| 222 | Providing chemical based water proofing treatment of approved make ( Indofil/ Pidilite / Asian) over bath/ WC brick bat coba & other locations as per the following procedure: a) Cleaning completely the existing surafce to remove all dirt with wire metal brush. b) Applying a primer coat of water proofing compound (diluted with clean water as per recommendations of manufacturer) over the entire area to be treated including filling up of cracks, if any with CM-1:3 mixed with waterproofing compound. c) Applying a first coat with water proofing compound with cement in 1:1 ratio. d) Providing and spreading of polycon based fibrous water proofing net for entire area including lapping as per manufacturer's specifications immediately after applying first coat and curing. e) Applying second coat with water proofing compond with cement in 1:1 ratio over the polycon based fibrous net. f) Applying top coat with undiluated water proofing compound. |
| 223 | Providing and fixing 32/40/50/65 mm dia. CP brass coupling with approved quality CP brass Mosquito proof jali including providing Galavanised MS bend and any other GI speacials if required for fixing the coupling, jointing materails etc. complete as specified and directed by Engineer- in- Charge. Supplying & fixing following fittings & fixtures as directed by the EIC & as per samples kept in unit stores |
| 224 | PVC connection pipe, heavy duty type of best quality, 15 mm dia, 600 mm long with stainless steel check nuts of 15 mm dia and PVC / silicon /rubber washer at both the ends. (Minimum pressure rating 10 Kg/cm2) (Suitable for hot water) |
| 225 | Heavy quality solid plastic seat and lid of white shade with C.P. brass pillar hinges conforming to IS 2548 (Hollow type of European water closet/ Anglo Indian Water closet / Single suit water closet) ) |
| 226 | Heavy quality C.P. brass waste coupling (32 mm /40 mm dia), heavy half / full thread (Minimum weight 200 gms) |
| 227 | 15 mm dia CP brass screw down, non fancy BIB TAP having full turn of M/s. TECHNO or other approved make conforming to IS 781-1984 and its latest amendments and ISI marked. (Minimum weight 400 gms). |
| 228 | 15 mm dia CP brass screw down, non fancy Pillar tap having full turn of M/s. TECHNO or other approved make conforming to IS 1795-1982 and its latest amendments (Minimum weight 650 gms). |
| 229 | 15 mm dia CP brass screw down, non fancy STOP COCK having full turn of M/s. TECHNO or other approved make conforming to IS 781-1984 and its latest amendments and ISI marked. (Minimum weight 400 gms). |
| 230 | 15 mm dia CP brass bib tap Top portion consists of handle, spindle, washer plate and washer nut (jumble valve), PVC/ silicon washer etc of M/s. TECHNO or other approved make conforming to IS 781-1984 and its latest amendments and ISI marked. (Minimum weight 190 gms). |
| 231 | Heavy quality C.P Brass non fancy round Shower rose of 75 mm dia with built in ball joint, pivot type with full threaded coupling suitable for fixing on G.I. water pipe line of 15 mm dia, having minimum weight of 125 gms, all as per specifications. |
| 232 | Best quality PVC corrugated flexible pipe, non spring type, having PVC waste coupling 32/40 mm dia, waste pipe of 25 mm dia having 900 mm length with wall thickness of 0.5 mm, having PVC waste outlet bottom piece, suitable for Kitchen sink/ Wash basin |
| 233 | Heavy Quality CP brass hand held jet spray (Health Faucet) for ablution (minimum weight of 250 grams for CP brass jet spray only) without pipe & wall bracket etc. |
| 234 | Heavy Quality PVC flexible pipe with SS metal thread braided/wrapped of 15 mm size having minimum length of 1.00 metre for connection with washers for connection of hand spray with washer etc complete. |
| 235 | Kitchen sink waste coupling of 100 mm nominal size with 32/40 PVC reducer cum adaptor |
| 236 | 32 mm dia C.P. brass bottle trap with C.P. brass extension piece & wall flange etc complete |
| 237 | spindle (Code no : ZCA - 001) of M/s Jaquar |
| 238 | Spindle (Code no: ZCQ - 048) of M/s Jaquar |
| 239 | Spindle (Code no: ZCS - 001/ 002) of M/s Jaquar |
| 240 | washer (Code no: ZCA - 005 ) of M/s Jaquar |
| 241 | top cap (Code no: ZKB - 002) of M/s Jaquar |
| 242 | knob (Code no: ZKB - 001) of M/s Jaquar |
| 243 | Aerator of M/s Jaquar |
| 244 | Knob (Code no: ZKB- 005) of M/s Jaquar |
| 245 | Knob (Code no ZKB - 150/057/ 150) of M/s Jaquar |
| 246 | Providing & fixing approved heavy quality solid plastic seat and lid of white shade with C.P. brass pillar hinges conforming to IS 2548 and including cost of removing the existing one depositing to deptt. stores etc complete all as per specifications and as directed by the Engineer-in-Charge, |
| 247 | a) Hollow type of European water closet |
| 248 | Providing and fixing universal Internal Kit of approved make for PVC flush tank (Syphon set + Ball Cock set+ Button Lever set) that fits most of the standard cisterns/flush tanks/ . The kit consists of a Syphon set the controls the outflow of the water, a ball cock set (adjustable) that controls the water inflow and filling of the tank, a lever set that controls the release of water. Made from heavy duty plastic etc. complete as per manufactures specification and as directed by EIC. |
| 249 | Universal Internal Kit of approved make for Flush tank having single syphon set+ 1ball cock set+1 button Lever set |
| 250 | Universal Internal Kit of approved make for water saving Compact Flush tank (Flush tank+commode) having dual flush valve syphon set+ adjustable 1ball cock set+1 set of push buttom. |
| 251 | Providing and fixing in position heavy pattern screw down gun metal Gate Valve conforming to IS:778 with hand wheels at top including testing for 10 Kg./ Sq.Cm. pressure with clean and potable water with a minimum testing duration of two hours etc including removing old gun metal Gate valve & returning to deptt stores etc complete all as per specifications and as directed by the Engineer in Charge. |
| 252 | a) 15 mm dia. |
| 253 | b) 20 mm n.b. |
| 254 | Providing and Fixing cPVC Ball valve with S.S balls & Specials, if required of approved make suitablefor pipe pressure class, making water proof joints,for pipe pressure class, making water proof joints,ncluding cost of jointing material and cPVCspecials if required, testing the joints etc. completeas per directions of EIC.SDR-11 (IS 15778)-cPVC Ball Valve |
| 255 | 15 mm dia. |
| 256 | 20 mm dia. |
| 257 | Providing & fixing in position approved quality CP brass stop cock/angle cock/Bib tap / Sink tap etc. of 15 mm nominal dia. with IS mark / approved make of following type including providing & fixing GI specials ,wall flanges and fixing to concealed / exposed G.I.pipe line with leak proof threaded joints using spun yarn, white zinc etc., testing the joints, rectifying the leaky joints, if any, including cleaning etc. complete all as per specifications and as directed by Engineer- in- Charge. |
| 258 | C.P brass Sink Tap with swinging casted Spout (wall mounted type ) similar to 'Florentine series' of ' JAQUAR' Cat. No. FLR-5347 ND. |
| 259 | a) C.P. brass Pillar Cock 15 mm size auto closing system with Aerator 'PRESSMATIC' as per'Jaquar' cat. PRS- 031. |
| 260 | a) C.P.brass 15 mm size auto closing Urinal Flush valve with wall flange Pressmatic as per JaJaquar cat. No. PRS-077. |
| 261 | CP brass Coat Hook of Jaguar Cat. No.ACN-1161N |
| 262 | Providing and fixing Kitchen sink waste coupling of approved make with choke-stop strainer has broader outlets with 1½ - inch diameter - with ISI mark including removing the existing & depositing to deptt stores etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 263 | Providing and fixing 40/50mm dia CP brass coupling with approved quality CP brass Mosquito proof jali including providing Galavanised MS bend and any other GI speacials if required for fixing the coupling, jointing materails etc complete as specified and directed by EIC. |
| 264 | Arresting leakage from upper floor flat toilet/ bathroom/kitchen by repalcing damaged GI / cPVC pipe lines, nahani trap, CI/ uPVC pipes, filling the joints, grouting, providing waterproofing treatment etc complete all as per specifications & as directed by the in-Charge. Note :- (new Ceramic tiles dado/ flooring required for re fixing for the job will be paid separately in relevant item) |
| 265 | Labour charges for attending emergency complaint of exposed PH fitting leakage including all material like-tee/elbow/coupling of GI/CPVC/PPR, solvent, tools etc. complete all as per specifiction and as directed by EIC |
| 266 | Labour charges for attending emergency complaint of concealed PH fitting leakage including breaking of tiles/plastering/concrete and providing all the required material like tee/elbow/coupling of GI/CPVC/PPR , solvent, tools etc. complete all as per specifiction and as directed by EIC |
| 267 | PART III - ELECTRICAL WORKS |
| 268 | Supply and fixing of the following materials required for maintenancea) Fan Accessories |
| 269 | Ceiling fan canopies |
| 270 | Capacitor 2.5 mfd MPP type (metal body explosion proof) for ceiling Fan |
| 271 | Bearings for ceiling fan (6201 & 6202) |
| 272 | Safety chain with fiting thickness 1.5mm - 2.00mm, length 1 Mtr |
| 273 | Instantaneous mini water heaters accessories |
| 274 | Heating elements / Coil of 3Kilowatt power spherical type double nipple/cup type suitable for 1 liter instantaneous mini water heaters,cup type,similar to sparehot make |
| 275 | Thermostat for 3 Kw instantaneous mini water heaters, having Temperature range from 25 - 75 degree celcius of 20A, 240 V, IS - 3017class- 1, 175 mm, Type BST - 7 suitable for 3KW instant water heater. |
| 276 | Thermal cutout for 3 Kw instantaneous mini water heaters, having Temperature range 90 degree celcius of 20A, 240 V, class- 1, 175 mm, Type BST - 7 suitable for 3KW instant water heater. |
| 277 | Packing rubber / Gasket, for 3 KW instantaneous mini water heaters |
| 278 | Indicator Lamp, for 3 Kw instantaneous mini water heaters |
| 279 | Fusible plug, for 3 Kw instantaneous mini water heaters |
| 280 | Safety-Valves, for 3 Kw instantaneous mini water heaters |
| 281 | PVC Safety-tube, for 3 Kw instantaneous mini water heaters |
| 282 | Switches/ sockets/ DP switches similar to CIVIC-XP of M/s. Vinay. |
| 283 | 6A, SP one way switch |
| 284 | 6A, SP bell push |
| 285 | 6A , 2/3 pin socket with shutter |
| 286 | 16A, SP one way switch |
| 287 | 6/16A , 5 pin socket with shutter |
| 288 | Ceiling fan regulator-80W(Capacitor type) SOC.Size |
| 289 | Electronic Musical door Bell having Poly Carbonated External body, bul bul bell tune, including transformer, transmitter, amplifier, 250 V, AC, Similar in all respect to Vinay Rosy Bell |
| 290 | Lamp Holder & 5\\" round PVC plate / Square Box Batten Holder / Angle holder / pendent holder/ ceiling rose |
| 291 | Angle holder |
| 292 | Batten holder |
| 293 | ceiling rose |
| 294 | 5\\" round PVC plate / Square Box with nylon / rawal plug, GI wood screws |
| 295 | Switches/ sockets/ DP switches similar to Myrius series of M/s. Legrand make. |
| 296 | 6A, SP one way switch,Myrius catalogue number(6730 00) |
| 297 | 6A, SP one way bell push |
| 298 | 6A , 2/3 pin socket with shutter,Myrius catalogue number(6730 44) |
| 299 | 16A, SP one way switch,Myrius catalogue number(6730 08) |
| 300 | 6/16A ,socket with shutter,2 module,Myrius catalogue number(6730 45) |
| 301 | 6/16A ,socket with shutter,3 module,Myrius catalogue number(6730 83) |
| 302 | Blank Plates |
| 303 | Ceiling fan regulator-100W(Capacitor type),Myrius catalogue number(6730 29) |
| 304 | Plastic surface boxes similar to Myrius series of M/s. Legrand make with wood screws & nylon plug. |
| 305 | 1/2 module Plastic surface box |
| 306 | 3 module Plastic surface box |
| 307 | 4 module Plastic surface box |
| 308 | 6 module Plastic surface box |
| 309 | 8 module Plastic surface box |
| 310 | 8 (4 x 2 ) module Plastic surface box |
| 311 | White plate cover with frame similar to Myrius model of M/s Legrand |
| 312 | 1 module plate cover with frame, catalogue number(6732 01) |
| 313 | 2 module plate cover with frame, catalogue number(6732 02) |
| 314 | 3 module plate cover with frame, catalogue number(6732 03) |
| 315 | 4 module plate cover with frame, catalogue number(6732 04) |
| 316 | 6 module plate cover with frame, catalogue number(6732 06) |
| 317 | 8 module plate cover with frame, catalogue number(6732 08) |
| 318 | 8 (4 X 2) module plate cover with frame, catalogue number(6732 09) |
| 319 | 12 (6 X 2) module plate cover with frame, catalogue number(673212) |
| 320 | Switches/ sockets similar to Murano series of M/s. Crabtree make. |
| 321 | 10AX, SP one way switch, catalogue number(ACUSXXW101)) |
| 322 | 16AX one way switchMurano catalogue no (ACUSXXW161 |
| 323 | Ceiling fan regulator-80W(Electronic type 5 step), catalogue number(ACMFFXW005) |
| 324 | 1.1 kV grade PVC insulated multi stranded copper wires |
| 325 | 1.5 sq.mm 1.1 kV grade FRLS PVC insulated multi stranded copper wires |
| 326 | 2.5 sq.mm 1.1 kV grade FRLS PVC insulated multi stranded copper wires |
| 327 | 4 sq.mm 1.1 kV grade FRLS PVC insulated multi stranded copper wires |
| 328 | 25 x 16 mm casing capping with nylon / rawal plug, GI wood screws 3 SET per Meter |
| 329 | 1.1 kV grade PVC insulated, FRLS PVC extruded outer sheath copper flexible cable of following sizes |
| 330 | 3 C X 1.0 sq.mm copper flexible cable |
| 331 | 3 C X 2.5 sq.mm copper flexible cable |
| 332 | MCB/MCCB/RCCB/RCBO, Metal plug & socket DB's |
| 333 | 32 A Isolator,2 Module |
| 334 | Metal one way enclosure DP/TP/FP similar to M/s Legrant with nylon / rawal plug, GI wood screws |
| 335 | 20 A Metal Plug socket box with 20A SP MCB for AC power supply similar to M/s Legrand with nylon / rawal plug, GI wood screws |
| 336 | Bakelite sheet 3 mm thick machine cutting in piece as per the required size & shape with required hardware. |
| 337 | Ceiling fan of following sizes without fan regulator |
| 338 | 900mm sweep similar to SAMRAT model of M/s Havells with safety chain |
| 339 | 1200mm sweep similar to SAMRAT model of M/s Havells with safety chain |
| 340 | 1400mm sweep similar to SAMRAT model of M/s Havells with safety chain |
| 341 | 1 ltr. Mini instantaneous pressure type water heater complying to IS 8978, vertical square type operating on 240V AC ,50Hz supply with 3kW heating element complete with all accessories ISI marked with stainless steel inner container and 23 SWG stainless steel outer container, pressure release valve, thermal cutout, fusible plug,2.5 sq.mm PVC copper wires for inter connections, 3C X 2.5sq.mm flexible chord etc. |
| 342 | Providing & fixing of MS fan hook consisting of 100 mm T shape 65mm X 65mm X 6mm MS member fixed 4 numbers of good quality M10 anchor fastners including S hook for fixing of ceiling fan including all accessories,painting ,labours etc. as per specification & as directed by EIC. |
| 343 | Part III - Rebate Items |
| 344 | Rebate for taking away dismanteled item by the contractor…… |
| 345 | a) Teak wood |
| 346 | b) Scrap wood |
| 347 | c) Panelled / Flush door shutter up to 38 mm thick |
| 348 | d) CP brass PH items like bib tap, pillar cock, stop cock, …… |
| 349 | i) bib tap |
| 350 | ii) stop cock |
| 351 | iii) pillar tap |
| 352 | iv) bottle trap |
| 353 | v) waste couplings |
| 354 | vi) towel rod |
| 355 | e) GI Pipes |
| 356 | i) 15 mm n.b |
| 357 | ii) 20 mm n.b |
| 358 | iii) 25 mm n.b |
| 359 | iv) 32 mm n.b |
| 360 | v) 40 mm n.b |
| 361 | vi) 50 mm n.b |
| 362 | vii) 65 mm n.b |
| 363 | viii) 80 mm n.b |
| 364 | f) replacement of CI & PVC pipes |
| 365 | i) 75 mm dia. |
| 366 | ii) 100 mm dia. |
| 367 | g) GM gate valves up to 50 mm dia. |
| 368 | i) 15 mm n.b |
| 369 | ii) 20 mm n.b |
| 370 | h) PVC flushing cistern |
| 371 | MS/Al Windows made of Z Sections/Grill Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail