| 1 | Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with bolts nuts, washers, anchor plates etc completee in all respect. PWD SOR 2018 S.I. No. 651 |
| 2 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect PWD SOR 2018 S.I. No. 1455 |
| 3 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD SOR 2018 S.I. No. 501 (a) 16 Sq mm 4 Core |
| 4 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed,underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge.PWD SOR 2018 S.I. No. 503 (a) 16 Sq mm 4 Core |
| 5 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PWD SOR 2018 S.I. No. 504 (a) 16 Sq mm 4 Core |
| 6 | Construction of High Mast Plinth |
| 7 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PWD SOR 2018 S.I. No. 725 B |
| 8 | Supply and Fixing of MLEDP60 Twin Unit Aviation Obstruction Light Bajaj/Crompton/Havells/ Equivalent with red glass B.C. Holders ETC. Complete in all Respect MR |
| 9 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.PWD SOR 2018 S.I. No. 807 F (II) 40 Amp TPN |
| 10 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.PWD SOR 2018 S.I. No. 716 |
| 11 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No.1307 (C ) |
| 12 | Supply and wiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4.0 sqmm FR PVC insulated multistranded copper conductor cable as earth continuity wire etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No.222 (C ) Please Enable Macros to View BoQ information |