| 1 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and gettingout soft loose soil complete all as specified and directed. |
| 2 | Excavating over areas, n exc1.5 m deep and getting out soft/loose soil complete all as specified and directed. |
| 3 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for column footings, manholes or required level or slope for laying of pipes/cables, etc. not exceeding 10 Sqm on plan and not exc 1.5 mtr in depth and getting out in soft/Loose Soil complete all as specified and directed. |
| 4 | M&L for PCC 1:3:6 type C-2 (Using 40mm graded stone aggregate) as in fdn filling and mass concrete complete all as specified and directed. |
| 5 | M&L 100 mm thick cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in base of flooring complete all as specified and directed. |
| 6 | M &L for Plain cement concrete in foundation filling type D-2 1:4:8 (40mm graded aggregate) and mass concrete complete all as specified and directed. |
| 7 | M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in, built in cement mortar 1:4 complete all as specified and directed. |
| 8 | M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in, built in cement mortar 1:6 complete all as specified and directed. |
| 9 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. exc. 25 cm in Hard/dense soil complete all as specified and directed. |
| 10 | Removing excavated material/soil exc. 1.5 km but n exc. 5 km and depositing outside of MoD land where complete all as specified and directed. |
| 11 | M&L for hardcore of gauge not exceeding 63mm,deposited, spred and levelled in layer not exceeding 15cm thick, watered and rammed to true surface complete all as specified and directed. |
| 12 | M&L 100mm thick for PCC 1:3:6 type C-2 (Using 40mm graded stone aggregate) as in Sub base complete all as specified and directed. |
| 13 | M & L rough finished surfaces of concrete Formwork flat to sides of concrete foundations, footing , bases of columns, raft and raft beams , sides and soffits if any of foundation and plinth beams and similar work complete all as specified and directed. |
| 14 | M & L rough finished surfaces of concrete flat form work flat to sides and soffits of lintle or roof beams, lintels, cantilevers, shelves including supports etc. complete all as specified and directed. |
| 15 | M&L for RCC Type B-1, 1;2:4 (20mm graded aggregate) in fdn and footing and plinth beam complete all as specified and directed. |
| 16 | M&L for RCC Type B-1, 1:2:4 (20mm graded aggregate) in lintels beam, roof beam over 1.5m clear span and other similar bands, etc. complete all as specified and directed. |
| 17 | S&F for TMT bars 10mm dia and over, cut to length, bent to shape required including craking, bending spirally,hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | Ditto all as per item No. 17 but 5mm dia and over up to and including 10mm dia in stirrups. |
| 19 | S & F rolled mild steel roof trusses (framed), trussed purlins, rails and fastenings and heavy bracket framing, confirming to Fe 410 - W including distance pieces, cleats, etc., complete all as specified and directed. |
| 20 | S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of FE 410-W (Gde-E-250) as directed by Engr in Charge. |
| 21 | S & F in MS screw bolts of dia 11-15 mm ( machine made ) with hexagonal or square at one end and screwded with other end or screwed both ends length of bolt not exc 5cm long complete all as directed by engineer in charge. |
| 22 | S&F MS frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks fixing with necessary arrangements all as directed by Engr-in-Charge. conforming to Fe-290 Gd E-165 complete all as specified and directed. |
| 23 | M & L for preparation of new steel surface of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer in charge. |
| 24 | S&F Pre -painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall,fixed with self tapping screwed complete all as specified and directed. |
| 25 | S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 26 | S & F 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 27 | S & F 150 mm dia Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges complete all as specified and directed. |
| 28 | S&F 3-4 mm thick ACP (Aluminium Composite panel) fixed to wall cladding with suitable fixing arrangements all as specified and directed by the Engr-in-charge. |
| 29 | M&L for 15 mm thick rendering in CM (1:4) on brick/concrete surface finished even & smooth without using extra cement with WPC @ 3% by weight of cement complete all as specified and directed at site. (WPC will be paid seperately) |
| 30 | Supply only integral water proofing compound complete all as specified and directed |
| 31 | M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 to be finished even smooth with out using extra cement as directed and specified by engineer in chanrge |
| 32 | M&L Preparation new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed. |
| 33 | M&L for two coat acrylic interor emulsion over one coat of priming chalk whiting on new plastered surfaces preparatory to distemper incl preparation of wall surface complete all as specified and directed. |
| 34 | M&L 75mm thick PCC 1:3:6, type C-2 using 40 mm graded stone aggregate as in plinth protection complete all as specified and directed. |
| 35 | S&F Factory Made Powder Coated aluminium frame for doors, windows, ventilators powder coated (thickness of powder coating not less than 50 micron) with one or more rebates including jointing cleat for fixing etc complete all as specified and directed. |
| 36 | S&F Factory made Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note:-1. The rate is inclusive of all fixings of builders hardware such as hinges, bow handles, locking arrangements rubber beading for fixing of glass etc complete all as directed by Engr-in-Charge. 2. Glass and wiremesh shall be measured and paid separetely |
| 37 | M&L for 4.8 mm thick sheet glass ordinary quality and glazing with aluminium beading n exc in each pane complete all as specidfied and as directed. |
| 38 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 39 | M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregates, as in kerb or side of path and the like including weathering, slightly rounded or chamfered angles and throating for internal surface chanel complete all as specified and directed. |
| 40 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming FE 410-W (Gde-E-250) complete all as specified and directed. |
| 41 | Supply and fix 1000 litres capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete and including dismantling of old tank complete all as specified and directed.. |
| 42 | M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18sqm in floor etc,over 15 mm thick screed bed in CM(1:4),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed. |
| 43 | M&L for Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match rendering in CM (1:4), 10mm thick on fair faces of brick work or concrete surfaces for fixing of wall tiles complete all as specified and directed. |
| 44 | M & L for plain cement concrete Type B-1, 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ in as in copings, bed plates and the like including weathering, slightly rounded or chamfered angles & throating and use of form work complete all as specified and directed. |
| 45 | M&L for point wiring light/ fan point with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including PVC conduit medium grade not less than 20 mm dia, ISI marked, duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated FRLS unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly for the following incl making good to surface with CM(1:4) plaster and paint to match the surface complete incl provn of electrogalvanised steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc complete all as specified and directed |
| 46 | Ditto all as per item No 45 above but for One 5 pin 5 amps socket outlet on same board with cables of size 1.5 sqmm |
| 47 | Ditto all as per item No 45 above but for One 5 pin 5 amps socket outlet on independent board with cables of size 2.5 sqmm |
| 48 | Ditto all as per item No 45 above but for One 6 pin 15/16 amps socket outlet on independent board with cables of size 2.5 sqmm |
| 49 | S&F Switch Piano Flush button single pole one way 5 Amp complete all as specified and directed. |
| 50 | S&F socket outlet flush type 3/5 pin 5/6 Amps 230V AC complete all as specified and directed. |
| 51 | S&F switch piano flush single pole one way 15/16 Amps complete all as specified and directed. |
| 52 | S&F socket outlet flush type 5/6 pin 15 Amps 230V AC complete all as specified and directed. |
| 53 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 54 | Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 55 | Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 56 | Supply & fixing MCB, SPN, AC, 240 volts of 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 57 | Supply and fixing LED bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 58 | Supply and fix LED integral flood light luminaires 200 watt in powder coated with aluminium die cast housing and frame,high efficiency,long life LEDs,loop in loop out connector,10 A G.F.P for each wiring heat resistant toughned glass in the front with unique flood optics to ensure uniform distribution and IP 66 protection complete assembly with LEDs,driver and accessaries pre wired up to terminal block including connection on pole including taking down of old /unserviceble light fitting complete all as specified and directed. Make- Orient cat No-LFAP-200-C or equivalent |
| 59 | Supply installation, testing and commissioning of split heat pump water heater system 1000 ltr (2x500 ltr) capacity with their quick heating technology, which saves up to 70% power.Key features :-Intelligent controller - It should be compatible to set the temperature and time when hot water is required can be easily set.Isolated safe condenser :- Design shall be according to european standards to ensure safety and superior conduction of heat.High efficiency compressor :- Heat pump water heater should ensure faster heat exchange more hot water and increased saving.Titanium plus coating :- The titanium enamel coating shall be provided inside the tank and heating element to prevent corrosion by handing even the toughest water conditions, providing reliable and healthy water for years to come.Magnesium anode :- The water heater with a bigger Magnesium anode should be provided to prevent corrosion of the inner tank and thus extends its life. Isolated safe controller :- Designed according to europen standards to ensure safety and superior conduction of heat.High efficiency compressor :- This heat pump water geyser ensures faster heat exchange more hot water and increased savings. Please Enable Macros to View BoQ information |
| 60 | Supply installation, testing and commissioning of split heat pump water heater system 1000 ltr (2x500 ltr) capacity with their quick heating technology, which saves up to 70% power.Key features :-Intelligent controller - It should be compatible to set the temperature and time when hot water is required can be easily set.Isolated safe condenser :- Design shall be according to european standards to ensure safety and superior conduction of heat.High efficiency compressor :- Heat pump water heater should ensure faster heat exchange more hot water and increased saving.Titanium plus coating :- The titanium enamel coating shall be provided inside the tank and heating element to prevent corrosion by handing even the toughest water conditions, providing reliable and healthy water for years to come.Magnesium anode :- The water heater with a bigger Magnesium anode should be provided to prevent corrosion of the inner tank and thus extends its life. Isolated safe controller :- Designed according to europen standards to ensure safety and superior conduction of heat.High efficiency compressor :- This heat pump water geyser ensures faster heat exchange more hot water and increased savings. Please Enable Macros to View BoQ information |