| 1 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed. |
| 2 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- Make of cable : Plaza/Polycab/Finolex/ Havells |
| 3 | One light/ fan/ exhaust fan/ buzzer point controlled by one switch. |
| 4 | One 3 pin socket outlet 6 Amps, Independent board with cables 1.5 Sqmm size. |
| 5 | One 3 pin socket outlet 6 Amps,same board with cables 1.5 Sqmm size. |
| 6 | One light point controlled by two 2- way switches, with cable 1.5 Sqmm size. |
| 7 | All as per item ser no-2 above here in before but one 3 pin socket outlet 6/16 Amps, indipendent board with cables 4.0 Sqmm size.Make :- Polycab/Finolex/Plaza/Havells |
| 8 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into PVC Conduit and Casing & caping fixed on wall/roof/ceiling including wall cutting etc of size not less than 20 mm dia including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- Make for PVC casing & caping: SUDHAKAR / AVON PLAST /PLAZA , Make for Copper cable: Finolex/Polycab / Plaza. |
| 9 | One light point controlled by one switch. |
| 10 | One 3 pin socket outlet 6 Amps, indipendent board with cables 1.5 Sqmm size. |
| 11 | All as per item ser no-4 above here in before but one 3 pin socket outlet 6/16 Amps, indipendent board with cables 4.0 Sqmm size. Make :- Polycab/Finolex/Plaza |
| 12 | M&L for sub main wiring for phase and neutral with PVC FRLS insulated unsheathed multi stranded along with earth wire FRLS PVC insulted copper conductor, single core cable in and including surface/concealed /PVC conduit appropriate size including cutting chases on brick walls concrete surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishesas specified for the following sizes. Make for Copper cables: Finolex/Polycab / Plaza/ Havells. Make of PVC Conduit: SUDHAKAR/FINOLEX/AVON PLAST. |
| 13 | 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire |
| 14 | 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire |
| 15 | 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire |
| 16 | 2x 10.0 sqmm and 1x 10.0 sqmm as earth wire |
| 17 | 4x 10.0 sqmm and 2x 10.0 sqmm as earth wire |
| 18 | Supply and fixing in repair of modular switch one way 6A white Active one module all as specified and as directed by the Engineer-in-Charge |
| 19 | Supply and fixing in repair of modular fan step regulator,120 W-2 module all as specified and as directed by the Engineer-in-Charge.Make: Havells(Crabtree)/Legrand/Plaza. |
| 20 | Supply and fixing in repair of modular socket 6A, 3 pin combined two module all as specified and as directed by the Engineer-in-Charge |
| 21 | Supply and fixing in repair of modular switch 16A, 3 pin combined two module all as specified and as directed by the Engineer-in-Charge |
| 22 | Supply and fixing in repair of modular socket 16A, 3 pin combined two module all as specified and as directed by the Engineer-in-Charge |
| 23 | Supply and fixing in repair modular bell push 6A one module complete all as specified and as directed. |
| 24 | Supply and fix Energy saving not less than 35 Watts LED light fitting ,IP66 powder coated pressure die cast aluminium high power street light with heatresisant toughened glass with lens by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two nos made out of 25x3 mm FI incl two coat of synthetic enamel paint over a coat of red oxide primer, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm from ceiling rose to fitting and including taking down old u/s damaged all as specified. Make Surya/Havells/Philips/CROMPTON. |
| 25 | S& F for modular sheet metal enclosure double pole and neutral with a three pin and earth plug and socket complete with one SP MCB 25-32 Amps. Make: Legrand/ Siemens/Scheneider/ABB |
| 26 | S&F in repair for decorative wall light fixture made up of Polycarbonate, suitable for 9w LED Lamp B22 Base with LED lamp of 9w complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader. |
| 27 | S & F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc and including taking down old all as specified and as directed by Engr-in-Charge . Make: Anchor/Cona/Leader/Lisha. |
| 28 | S&F in repair for switch piano, flush type single pole , one way 6 amp complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader |
| 29 | S&F in repair for switch socket combination 2 in 1, 5 pin, 6 Amp flush type complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader |
| 30 | S&F in repair for bell push flush type, 6 Amp complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader |
| 31 | S&F in repair for switch piano, flush type single pole , two way 6 amp complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader |
| 32 | S&F in repair for switch socket combination 2 in 1, 6 pin, 6/16 Amp flush type universal complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader |
| 33 | Supply and fix Eco compact wall mounted LED batten for T8 LED tube with ULTRON high efficency LED polycarbonate tube with in built driver and metal heat sink 20/22 watt icluding taking down old unserviceable fittings all as specified and as directed by Engr-in-Charge.Make : Crompton /philips/ wipro/ Havells/Surya |
| 34 | Supply and fix high efficiency wall mounted LED batten type polycarbonate tube of 10W 2 ft LED and including taking down old unserviceable fittings all as specified and as directed by Engr-in-Charge . Make : Havells/ Philips/Crompton/wipro/ Surya. |
| 35 | S&F MCB,DB SPN 02 way in SS enclosure type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.Make: Legrand/ Siemens/Scheneider/ABB. |
| 36 | Supply and fix for MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABBNote : Including taking down old unserviceable. |
| 37 | Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C urve complete all as specified and as directed by Engr-in-chargeMake: Legrand/ Siemens/Scheneider/ABBNote : Including taking down old unserviceable. |
| 38 | S&F sheet metal enclosure vertical TPN MCCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements all as specified and directed Note :-(i) Including taking down old u/s DB, MCCB and MCB's (ii) MCCB and MCBs shall be measured and paid separately under the respective item of shedule. Make: Legrand/ Siemens/Scheneider/ABB. |
| 39 | All as per item ser no-27 above here in before but one vertical TPN MCCB DB 8 way double door . |
| 40 | All as per item ser no-27 above here in before but one vertical TPN MCCB DB 12 way double door . |
| 41 | S&F sheet metal enclosure Horizontal TPN MCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements all as specified and directed Note :-(i) Including taking down old u/s DB, MCB's (ii) MCBs shall be measured and paid separately under the respective item of shedule. Make : Legrand/ Siemens/Scheneider/ABB. |
| 42 | All as per item ser no-30 above here in before but one Horizontal TPN MCB DB 6 way double door . |
| 43 | S&F sheet metal enclosure Vertical TPN MCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements all as specified and directed Note :-(i) Including taking down old u/s DB, MCB's (ii) MCBs shall be measured and paid separately under the respective item of shedule. Make : Legrand/ Siemens/Scheneider/ABB. |
| 44 | All as per item ser no-32 above here in before but one Vertical TPN MCB DB 6 way double door . |
| 45 | All as per item ser no.32 above here in before but one Vertical TPN MCB DB 8 way double door . |
| 46 | All as per item ser no-32 above here in before but one Vertical TPN MCB DB 12 way double door . |
| 47 | S&F MCB,DB SPN 12 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.Make: Legrand/ Siemens/Scheneider/ABB. |
| 48 | S&F MCB,DB SPN 08 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule. Make: Legrand/ Siemens/Scheneider/ABB. |
| 49 | S&F MCB,DB SPN 04 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.Make: Legrand/ Siemens/Scheneider/ABB. |
| 50 | Supply and fix for MCCB 4 pole sheet metal enclosure with double door with spreader terminals, insulating phase barrier and hardware with neccesary arrangements complete all as specified and as directed by Engr-in-charge.Notes: (i) Including taking down old unserviceable DB and MCCB.(ii) MCCB shall be measured and paid separately under the respective item of schedule.Make: L&T/ Legrand/ Siemens/ Schneider /ABB/ C&S |
| 51 | Supply and fix for MCB TP 415 V, 25-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable. |
| 52 | Supply and fix in repair for MCB TPN 415 V, 63-100 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable. |
| 53 | Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type type 200 Amps with breaking capacity 36 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB,Note : Including taking down old unserviceable. |
| 54 | Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type type 150/160 Amps with breaking capacity 36 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB,Note : Including taking down old unserviceable. |
| 55 | Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type type 125 Amps with breaking capacity 10 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable. |
| 56 | Supply and fix for MCCB 4 Pole, 415 V,adjustable Thermal & Fixed Magnetic setting type type 100 Amps with breaking capacity 10 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable. Please Enable Macros to View BoQ information |
| 57 | Supply and fix for MCCB 4 Pole, 415 V,adjustable Thermal & Fixed Magnetic setting type type 100 Amps with breaking capacity 10 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable. Please Enable Macros to View BoQ information |