| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 3 | Providing & laying in position cement concrete of 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering - All work up to plinth level. |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Supplying and fixing of octagonal type, 10 Meter height designed as per ILE TR7 & BS5649 for structural design & as per IS875 (Part III), 1987 amended up to date, Bottom dia 175 mm & top dia 70 mm as per technical specifications or as per manifacturer specifications (design and drawing to be approved by Engg in Charge) capable to withstand the wind pressure 50-55KM/Hr octognal hot galvanised suitable for the configuration of LED fittings with base plate of 275x 275 x 16 mm welded at the bottem and hole dia 28x50 mm complete with M 24 mm 04 nos nut bolt systematically located for holding the pole and nuts and bolts washer for earthing and fixing of channeled shaped LED Flood Lighting Bracket (suitable for mounting of 3 Nos flood lighting luminair on existing octagonal pole with totally enclosed outdoor type front openable loop box with transparent hinged lid sealable, cable entry via metric knockouts suitable for 3.5 Core X 35 Sqmm PVC / XLPE UG CABLE including providing and fixing 3/4 phase 100 Amp bus bar capacity connector with nut bolt arrangment , one 32 A DP MCB and 03 Nos 6 Amp SP- MCB \\"C\\" series, drilling holes connections, interconnections, earthing including providing necessary water proof gasket to the box complete in existing loop Box etc as required on site. ( / Bajaj / Utkarsh/Cromptono equivalent make).(Material will be supplied at site of BOP) |
| 8 | Supply, Installation, testing and commissioning of Set of max 3 luminaires with combined wattage 150 W each on exising pole having minimum system effecacy of 90 Lumen / Watt outdoor type LED Flood Light Luminaire of IP 66 and above having suitable pressure die cast housing / heat sink, driver, optics for operation in 230 Volts A.C, PF not less than 0.90, CRI>70, internal & external surge protection, LM/79-80 Colour tempature 6000 K, suitable with beam angle to meet desired alluminium level as per required technical specifications & suitable for mounting on the existing pole bracket including drilling of holes, wiring the existing pole with 2.5 sqmm FRLS grade PVC insulated PVC insulated copper conductor single core cable from loop box to fitting i/c providing and fixing suitable size of GI flexible pipe with accessories from top slot of pole to fitting connections, interconnections etc as per specification complete as required. (Philips/ HPL/ Bajaj/ Havells/ Crompton make) |
| 9 | Repair and maintenance of existing HI-Intensity, multifunctional autorotateable 360 degree,LED search light 300 watt narrow beam-7 degree,LM6 housing with heat sink, round in shape with replacement of defective VFD etc. as required. |
| 10 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.5 X 2.5 Sqmm |
| 11 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 12 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 13 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.up to 3.5x 35 sqmm |
| 15 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.up to 3.5x 35 sqmm |
| 16 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. up to 3.5x 35 sqmm |
| 17 | Providing and fixing of 7 Mtrs long hot dip galvanized octagonal pole withbase plate made in single section fitted with erection of the pole on provided RCC Foundationwith galvanized nuts etc as required. The following specifications should be adhered for pole &accessories:-a) Pole Top dia - 70mmb) Pole Bottom dia - 130 mmc) Thickness of sheet - 3mmd) Galvanized Base plate of size - 220mm X 220 mm X 12 mme) Set of foundation nut & bolts - 04 nos EN 8 grade galvanized 600 mmlength be supplied with galvanized nuts, washers, spacer plate & fixingtemplate. The pole shall be fixed using double nuts.f) The set of GS anchor plates having thickness 4mm should be providedat all the connecting joints for providing support.g) The galvanization should be more than 65 micron DFT both internallyand externally and pole should be designed for at least 169 km/hour maxwind speedi)The steel used for manufacturing pole should conform to BSEN 10025GRADE S 355JO an S 226 / IS 2062. |
| 18 | Providing and erection of 9 mtr long PCC pole etc as required |
| 19 | Providing, laying, fixing and commissioning of overhead armoured 3.5 X 25 Sqmm cable on pole to pole arrangement complete with clamps, saddles, thimbles,, binding material and all required accessories including dressing, clamping, testing and commissioning as required at site. The cable shall be properly supported between pole to pole for safe and reliable operation during flood conditions complete in all respect. |
| 20 | Providing and fixing MS/galvanized D-clamp of approved design and size on existing octagonal s pole, made out of MS flat/angle/pipe as required, complete with necessary nuts, bolts, washers, rubber lining (if required), drilling of holes on pole (without damaging structural integrity), tightening, alignment, and proper fixing for mounting of electrical accessories/cables/brackets, including anti-corrosive treatment with one coat of red oxide primer and two coats of aluminium/approved enamel paint or hot-dip galvanization, complete in all respects as per site requirement, direction of Engineer-in-Charge |
| 21 | Supplying and fixing of FR hot pressed moulded SMC (Sheet moulding compound) looping box hinged type having size inner día 300mm x 225mmx140mm having suitable hole at the bottom including SPMCB mounted on din rail and 4way heavy duty connector or 2 way brass connector (02 Nos hole type) mounted on 3mm thick bakelite sheet with additionaal triangular key type locking arrangement polymide gland PG-21 (02 Nos) suitable for cable size up to 3.5x25 sqmm gland plate with earthing arrangement 250 mm Gl patti (02 Nos) for holding the clamp to be fixed on the pole with the help of Gl clamp of size 100mm x 3mm (02 Nos) including making incoming and out going connections with suitable size of thimble etc as required as per direction of Engg in charge Sintex make dismantling of exising looping boxes etc as required |
| 22 | Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required . |
| 23 | Erection of G.I. Wire No. 8 SWG including binding etc. as required. |
| 24 | Providing and fixing following rating onload changeover switch 4 pole with encloser, making connections i/c dismentling the existing alongwith electrical acessories. a) 200 Amp |
| 25 | S/L of 3 Core cable 1.5 sqmm size of PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 from looping box to light fitting including interconnection with connector,testing complete etc as required |
| 26 | Provinding and fixing double pole single phase MCB Changeover in exeisting Sintex Box connection & testing etc complete as required 32 Amp |
| 27 | Provinding and fixing Connectors for Cable connection etc complete as required Please Enable Macros to View BoQ information |