| 1 | Rewinding of following sizes of centrifugal/ Mono block motor I/Cdismantling of old burnt winding and rewinding with suitable size of copper annealed copper wire complete with all accessories including dismantling and refixing of pump motor from site to authorise work shop and work shop to site etc complete as reqda) 30 HP |
| 2 | b) 7.5 HP |
| 3 | Servicing of following sizes of mono block / centrifugal pump set including replacement of mechanical seal, bearing. Bush, and brass impeller etc in the existing pump set including dismantling of pump from site to work shop and work shop to site etc as reqd from authorise cervice center .a) 30 HP |
| 4 | b) 7.5 HP |
| 5 | Replacement of the following old defective pipe and defective fittings I/c dismantling of defective /pipe and fittings including supply and fixing of B class GI pipe ( W/O fittings etc complete as reqd ( Make :- Pipe ;- Jindal GZB)a) 100 mm Dia GI Pipe |
| 6 | b) 80 mm Dia GI Pipe |
| 7 | c) 100 mm Bend |
| 8 | d) 80 mm Elbow |
| 9 | e) 80 mm/100mm flange |
| 10 | f) 100 mm/ 80mm GI Nipple –up to 300mm long |
| 11 | Replacement of following defective items I/c dismantling of items I/c supply and fixing of new items I/c testing and commissioning etc complete as reqd ( Make :- Kirloskar/ Sant/ SS) a) Gun metal flange foot valve -80mm Dia |
| 12 | b) Flange type Sluice valve -100mm Dia |
| 13 | c) brass gate valve - 50 mm dia |
| 14 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.a) 150 mm width X 50 mm depth X 1.6 mm thickness |
| 15 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc. as required Group C |
| 16 | Providing and fixing of 4 feet long 22 watt LED batten and fixing on the wall including fixing accessories and connection etc complete as reqd ( Make ; Havells / Bajaj/ Crompton ) |
| 17 | Lifting /draw out of 5 Hp 3 phase submersible pump with motor from the existing bore well with the help of chain kuppy and heavy labour I/c drawout steel rope, flat submersible cable ,50 mmdia GI pipe and other accessories etc and complete as reqd . |
| 18 | Lowering of 5 Hp 3 phase submersible pump with motor in the existing bore well with the help of chain kuppy and heavy labour I/c lowering steel rope, flat submersible cable ,50 mmdia PVC pipe and other accessories etc complete as reqd |
| 19 | Replacement of following defective items I/c dismantling of items I/c supply and fixing of new items I/c testing and commissioning etc complete with fixing accessories as reqd ( Make :- Kirloskar/ Sant/ Leader )a) Gun metal gate valve -50 mm dia |
| 20 | b) Gun metal Horigental non return valve-50 mm dia |
| 21 | Servicing, repairing and replacement of defective part of 5 Hp 3 phase submersible pump working voltage 440 volts 50 HZ ACsupply such as mechanical seal, double ball bearing , shaft , o ring etc complete as reqd . |
| 22 | Rewinding of old burnt 3 phase 5 HP submersible motor working voltage 440 volts 50 HZ AC supply I/C dismantling of old winding and rewing of motor with suitable copper bare wire I/c p/F rewinding accessories etc complete as reqd from authorise service centre and motor loading and unloading from site and workshop I/c transportation etc complete as reqd . |
| 23 | Replacement of damage old steel wire rope of size 6 mm dia covering with PVC sleeve and laying in the bore well along with existing PVC pipe and fixing with clamp etc complete as reqd . |
| 24 | Replacement of 3 corex4 sqmm burnt/ damaged flat submersible water proof PVC insulated and PVC sheathed copper cable and laying along with Existing PVC pipe and fixed with PVC tie etc complete as reqd . ( Make :- Havells/ KEI/ POLY cab) |
| 25 | Replacement of water proof submersible pump cable joint etc complete as reqd . |
| 26 | Replacement of following sizes of Lead free standard class PVC coloum pipe with PVC socket and lowering in existing bore well with the help of heavy labour and chain Kuppy along with existing submersible pump and motor etc complete with following specification .a) Make :- ASTRAL Limited)b) Size of Coloum PVC pipe:-60mm dia (OD)c) Pressure -20 KGF/CM2d) Inner size ;- 50mm diae) Catageory/ 2024101400120541SL-2 |
| 27 | Repairing of faultyburnt automatic star delta starter of 5Hp Submersible pump L&T make I/c providing and fixing of burnt copper wiring and relay, contractor etc complete as reqd . |
| 28 | Replacement of heavy duty suitable M.S clamp fabricated with M.S and providing and fixing of nut bolt with washer etc complete as reqd . |
| 29 | Replacement of following damaged, rusted items in the exiting suction water pipe line complete with fixing accessories etc omplete as reqd including dismantling of old rusted pipe etc ( make( Make :-Sant/ Leader/ Kirloskar /Unik)a) 65 mm dia brass foot valve – |
| 30 | b) 65 mm dia GI Elbow |
| 31 | c) 65 mm dia GI flange with packing |
| 32 | d) 65 mm dia GI nipple 300 mm long |
| 33 | e) 65 mm dia GI pipe |
| 34 | Less credit dimantled material shall be the property of contractor Please Enable Macros to View BoQ information |