| 1 | Maintenance works (Both Civil & Sanitary Plumbing) to the Bhawanipur Guest House of the University of Burdwan [2nd call] |
| 2 | Ordinary Cement concrete (mix 1:1.5:3) withgraded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.a) Ground Floor |
| 3 | Hire and labour charges for shuttering withcentering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works 25-30 mm thickapproved quality wooden plank shuttering in any concrete work a) Ground Floor |
| 4 | Reinforcement for reinforced concrete workin all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(i) Tor steel/Mild Steel(i) Upto 4 th floor roof in each addl. floor) Ground Floorremoving rubbish as directed within a lead of 75m.up to 150 mm thk |
| 5 | Brick work with 1st class bricks in cementmortar (1:6) |
| 6 | (a) In foundation and plinth |
| 7 | b. In super structure |
| 8 | Brick work with 1st class bricks in cement mortar (1:4) |
| 9 | In foundation and plinth |
| 10 | In superstructure, ground floor |
| 11 | 125 mm. thick brick work with 1st classbricks in cement mortar (1:4) in ground floor,drain etcpapering etc |
| 12 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. |
| 13 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. |
| 14 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. upto 150 mm. thick |
| 15 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 16 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary(i) |
| 17 | a. With 1:6 cement mortarb) 20 mm thick plasterGround Floor |
| 18 | b.With 1:3 cement mortar 10 mm thick plasterGround Floor |
| 19 | Removing old scale ,blisters etc of interior surface of walls ceiling by scraping etc and preparation surface with rendering or cement morter(1:2) as necessary. |
| 20 | Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick) for confarance room & waiting room only |
| 21 | Applying Interior grade Acrylic Primer ofapproved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)One Coat) Water based interior grade Acrylic Primer |
| 22 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of theEIC.One Coat |
| 23 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour,scaffolding and all incidentalcharges but excluding the cost of primer.ground floor super protective 100% Acrylic Emulsion |
| 24 | Scraping of moss, blisters etc.thoroughly from exterior surface of wallsnecessitating the use of scraper, wire brush etc.(Payment against thisitem will be made only when this has been done on the specific directionof the Engineer-in-charge |
| 25 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.wallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thickKg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.Area of each tile above 0.09 Sq.mColoured decorative |
| 26 | Supplying and laying true to line and level Double ChargeVitrified Tiles of approved brand conforming to IS 156222006 (Group B I a) and tested as per IS 13630:2006 (relevantparts) [Non-modular sizes for tiles with Water Absorption (av.)≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of6mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course and jointsgrouted with admixture of white epoxy grout materials ofapproved brand including spacer -2mm as directed andremoval of wax coating of top surface of tiles with warm wateand polishing the tiles using soft and dry cloth upto mirrorfinish complete including the cost of materials,Iabour and allother incidental charges complete as per direction of Engineer in Charge. (Note: This work should not be executed withoutspecific permission of Superintending Engineerln Ground FIoor:(size not Iess than 800mmX 800 mm X10.2 mm thk |
| 27 | Making one set of scaffolding only for replacing glass panels, painting,uprooting plant and another repairing works of building and S&P works forexternal works only with 10 cm. dia bamboo as main posts at the rate of 1metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fittingand fixing with necessary coir, nails etc. as per direction of the Engineer-incharge.3.9 mtr height |
| 28 | Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 29 | Priming one coat on steel or other metalsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 30 | Painting with best quality syntheticenamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :On timber or plastered surface :With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 31 | On steel or metal surface : |
| 32 | Applying Acrylic distemper to interior wall,ceiling with a coat of solvent based interior grade acrylic primer :(Two coats) |
| 33 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish and stacking anywhere within the compound as directed. |
| 34 | Dismantling artificial stone flooring upto 50 mm.thick by carefully chiselling without damaging thebase and removing rubbish as directed within alead of 75 m |
| 35 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thickwith uniform texture & without decorative veins in columns,wall, facia,rise etc. with 15 mm thick [avg] cement mortar(1:2) including making suitable arrangements to hold thestones properly by brass / copper hooks including pointing incement mortar (1:2) (1 white cement : 2 marble dust) withadmixture of pigment matching the stone shades all completeas per direction of the Engineer-in-charge including cost of allmaterials, labours, scaffolding, staging, curing androughening of concrete surface complete a.Area of each Granite slab above 1.00 Square meter |
| 36 | b.Area of each Granite slab > 0.60 upto 1.0Square meter. |
| 37 | Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity |
| 38 | Anti-termite treatment to the outside of foundationwith chemical emulsion by admixing chloropyrofosemulsifiable concentrate (1% concentration) withwater by weight, drilling 12mm. dia holes in concreteor masonry apron at an interval of 300mm. to a depth,of 300mm or more as close to the plinth wall aspossible and the chemical emulsion pumped into thoseholes to soak the soil below at a rate of 2.25 litres perlinear metre complete as per specification laid downin para 4.3.1.1 of Code I.S.-6313 (Part-III)-1981 |
| 39 | Cleaning the concrete surface by removing dirt and debris, marking defectiveocations and removing loose concrete by careful stripping untill hard surfaceis exposed, cutting the concrete to regular shape, wire brushing the exposedsurface and removing debris from site complete as per direction of theEngineer - in - Charge. |
| 40 | Applying epoxy based reactive joining agent for joining the old concrete withfresh concrete to be applied within manufacturer's specified time as permanufacturers specification. (0.4 Kg / m² of concrete surface). |
| 41 | Removing corroded worn out portion of reinforcement (when the area of baris damaged by more than 25%) by cutting and replacing the same by a newplain round bar of requisite diameter by binding with required lap / weldingwith old bar, including cost of reinforcement, complete in all respectincluding removing unserviceable materials from site as per direction of theEngineer - in - charge. Note : Payment on weight (Kg.) of newreinforcement |
| 42 | Ordinary Cement concrete (mix 1:2:4) withgraded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.Pakur Variety, Gr floor |
| 43 | Applying 2 coats of bonding agent with synthetic multi functional rubberemulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer'sspecification [Cement to be supplied by the Department] |
| 44 | Supplying and laying Polythene Sheet(150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 45 | M.S.or W.I. Ornamental grill of approved design joints continously welded with M.S.W.I.Flats and bars of window bars of windows,railing etc fitted & fixed with necy.screws & lugs Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr |
| 46 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite doorframe as per approved section with glass fibre reinforced plastic moulded skinsand a special sandwich core, so as to impart monolitaheic composite structure as66mm x 90mm |
| 47 | Labour for taking out door and window frame with or without horns and including shutter for repair replacement of different parts of the frame and refixing the same including mending good all damages complete.Upto area 2.5 sqm |
| 48 | Iron butt hinges of approved quality with ISI mark . (100mm x58mm x1.9mm) |
| 49 | Iron socket bolt of approved quality fitted and fixed complete.150 mm long x 10mm dia bolt. |
| 50 | Iron hasp bolt of approved quality fitted & fixed complete . 250mm long |
| 51 | Supplying Godrej mortice lock c.p.with latch and key 4 levers incl fitting and fixing complete |
| 52 | Hydralic door closer of approved quality as per I.S.I. Standard fitted and fixed complete.Medium (ISI size -2) |
| 53 | Iron door ring of approved quality 50mm dia fitted & fixed complete . |
| 54 | Anodised aluminium D-type handle of approved quality150 mm grip x10 mm dia rod |
| 55 | M. S. clamp for fixing door &window frame. (40mm x 6mm x 250mm.length) |
| 56 | Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts), reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only). |
| 57 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite doorshutters as per approved design with glass fibre reinforced plastic moulded skinsand a special sandwich core, so as to impart monolitaheic composite structure asper approved technology of Department of Science and Technology (DST) tosatisfy IS:4020 door testing performance criteriaIn ground floor 32 mm thick |
| 58 | Supplying profiles of required section madeof Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).In 10-12 Micron thickness Annodizing film coloured 2- track sliding window a. Bottom frame |
| 59 | b. Top and side frame |
| 60 | Shutter for all track sliding window. i) Bottom & Top member. |
| 61 | ii) Style side member. |
| 62 | iii) Interlock member. |
| 63 | h) Louvered window. i) Top, bottom and side member. |
| 64 | ii) Louvered Section. |
| 65 | iii) Cleat angle ( Non-annodized). |
| 66 | Fixed partitions i) Top , bottom & side member |
| 67 | ii)Intermediate member |
| 68 | iii)Glazing clip. |
| 69 | Movable door shutter i) Door frame. (Top & sides |
| 70 | ii)Shutter :Top rail |
| 71 | iii)Shutter :Bottom rail |
| 72 | iv)Lock rail |
| 73 | v)Door vertical |
| 74 | vi)Glazing cleap. |
| 75 | Labour charge for fabrication and installationof composite door, window , partitions made from annodized extruded alloy aluminium sections for the following units:-(A) Glazed aluminium sliding windows madeof extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Poly Shulphate sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC.The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleate angle etc. but excluded the cost of extruded aluminium sections, glass, neoprene / EPDM gasketing, locking arrangement and rollers- 2 track sliding window |
| 76 | Louvered window. |
| 77 | Partly glazed partly panelled or fully glazed single leaf alunminiumswing door made of extruded and annodized alloy aluminium sections,fabrication including cutting to proper shape and size, drilling andaligning, fitted with heavy duty hydraulic action floor sping placed in thefloor with mending damages,with top pin assembly of approve make andbrand, fitted with in built locking arrangement, flush bolt, glazing clipsand all other necessary fittings, fixtures, adhesives and joineries, cuttingglass of approved make to requisite shape and size fitting with dry setneoprene or EPDM gasketing, cutting to requisite shape and size panelboard (prelaminated particle block) fixing them with glazing clips as perdrawing, specification and direction of Engineer in charge |
| 78 | Partly glazed and partly panelled partition or fixed glazing made ofextruded and anodised alloy aluminium sections, fabrications aftercutting to proper shape and size, drilling and aligning fitted with inbuilt locking arrangement cutting the glass / board (prelaminated / particle /block) to requisite shape and size moulding the edges fitted and fixed glazing clips and dry set neoprine /EPDM gasket, along with all othernecessary arrangements for fixing the partition to walls, floors, beams,columns polysulphide sealant for water proofing if necessary complete inall respect as per drawing and specifications and direction of theEngineer in charge101.50mm x 44.45 mm |
| 79 | Acrylic distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer including cleaning and smoothening of surface-two coats |
| 80 | Supplying bubble free float glass of approvedmake and brand conforming to IS: 2835- i) 4mm thick coloured / tinted / smoke glass. |
| 81 | ii) 5mm thick clear glass |
| 82 | Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete |
| 83 | Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete.P.V.C. Door shutter 30 mm thk |
| 84 | Supplying best Indian figured glass viz. hammered, fluted, ribbed, pinhead etc. type including cutting to required sizes, setting on putty bases and fitted and fixed with nails and putty complete.(In all floors for internal wall & upto 6 m height for external wall) 3 mm thick (White |
| 85 | IRC fabric mesh of 75mm x 50mmx4.5mmx2.7mm on 50mm x 50mm x6mm old angle iron frames all round and one 37.5mm x 6mm M.S. flat bar overthe netting all round welded to angle iron frame and providing lockingarrangements if necessary and with two coats of synthetic enamel paint(Otherthan Hi-gloss) fitted and fixed with clamps or haskal doomney etc. complete includingflat stiffeners on every 1.0 m apart both ways. |
| 86 | Supplying,fitting & fixing in position suspended false ceiling with frame work ofaluminium hollow section of size 50mm X 25mm (2.0mm thickness) combined withaluminium corners of size 38mm X 25mm, suspended by aluminium hollow tubesection of size 38mm X 25mm having size of 600mm X 600mm ceiling withaluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprisingof proctective film, polyester coating, primer, aluminium coil, adhesive film,polyethylene core again with one layer adhesive film, aluminium bottom coatingand finally service coating as per manufacturer's specification finished withaluminium screw and silicon sealent complete in all respect including allincidental charges etc. as per direction of Engineer-in-charge. |
| 87 | Supplying ,fitting & fixing Eco-friendly, Moisture Resistant and Incombustable Gypsum plaster board /tiles (density>700 kg /Cum) conforming toIS 2095-Part 1, 2011 of size 595mm X595mm of approved design and brand placed inthe Grid module to form a false ceiling all complete as per drawing & directionof Engineer - in- Charge.False ceiling with12.5mm thick Square edged Gypsum Plaster Board / tiles |
| 88 | Wall paneling with Gypsum Plaster Board of 12.5 mm thick fitted to G.I. channelof 55 mmx50 mm placed at 300 mm c/c in horizontal direction and metal stand 55mmx48 mm placed @900 mm c/c in vertical direction connected with G.I.connecting clips. 12.5 mm thick Gypsum plaster based are to be fixed with G.I.channel by machine screws. The boards are to be joined with jointing compoundand fibre tape and finished with top coat etc the rate includes the cost of allmaterials, labour charges including scaffolding etc. complete as per direction ofthe Engineer-in-charge.In ground floor |
| 89 | Supplying,fitting and fixing G.I. pipes of TATA (M)make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.) a. 15mm dia(L) |
| 90 | b. 20mm dai(L) |
| 91 | c.25mm dia (M) |
| 92 | d. 40mm dia(M) |
| 93 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)For Exposed Work PVC Pipes (Dia) a.15mm |
| 94 | 25 mm |
| 95 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.) a. 15 mm |
| 96 | b. 20 mm |
| 97 | c. 25 mm dia |
| 98 | d. 32 mm |
| 99 | e. 40 mm |
| 100 | f. 50 mm |
| 101 | Supplying,fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.630 mm X 450 mm size |
| 102 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 103 | Supplying, fitting and fixing bib cock or stop cock Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 104 | Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 105 | Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately).With valamoid joints including sealing with sand cement morter (4:1) upto quarter depth 100mm dia |
| 106 | Supplying, fitting & fixing Cast iron single branch equal with door conforming to I.S. 1729/2002 including joining and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing the top with cement mortar (4:1)100mm dia. |
| 107 | Supplying, fitting & fixing Cast iron double branch equal with door conforming to I.S. 1729/2002 including jointing and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing the top with cement mortar (4:1)) 100mm dia. |
| 108 | Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (a) With valamoid joints including sealing the top with cement mortar (4:1 With valamoid joints including sealing the top with cement mortar (4:1 100mm dia. |
| 109 | Supplying, fitting & fixing H.C.I. bend without door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing the top with cement mortar (4:1) 100mm dia. |
| 110 | Supplying,fitting and fixing cast iron 'P' or 'S' trap conformimg to I.S. 3989/ 2009 and 1729/ 2002 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately100 MM a)P- trap |
| 111 | (b)S-trap |
| 112 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap |
| 113 | (b) With 'S' trap |
| 114 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.E.W.CBestolite (solid type) white |
| 115 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 116 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.900 mm long |
| 117 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.900 mm long |
| 118 | Supplying, fitting and fixing towel rail with two brackets.C.P. over brass, 25 mm dia. and 600 mm long |
| 119 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 635 mm X 395 mm X 420 mm |
| 120 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. |
| 121 | Supplying, fitting and fixing porcelain toilet paper holder of approved make with wooden spindle as necessary.Roll type size 250 mm X 125 mm |
| 122 | Supplying, fitting and fixing porcelain soap tray of approved make. Recessed soap tray of size 150 mm X 150 mm |
| 123 | Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover ofapproved make with rim of approved make (Heavy type)450 mm dia. |
| 124 | Removing sludge from septic tank, soak well etc. by methor labour includingdisposal of the same outside the compound as directedUpto 50 usersBeyond a lead of 150 metre and outside the Municipal limit |
| 125 | Cleaning soak pit by removing the top slab and replacing inner filling withjhama bats and repairing the pit as necessary including fitting the slab |
| 126 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992110 mm Single Socketed 3 Meter Length |
| 127 | Single Socketed 1.8 Meter Length |
| 128 | Fittings (a)Door Tee |
| 129 | (b)Bend 87.5º |
| 130 | (c)Door Bend (LH) & (RH) |
| 131 | (d)Cross Tee with Door |
| 132 | (e)Vent Cowl |
| 133 | (f)Pipe Clip |
| 134 | (g)110 X 110 P Trap |
| 135 | 110X110 S Trap |
| 136 | (i)Passover |
| 137 | (j)Plain Floor Trap without Top tile & Strainer |
| 138 | (k)Round Jali |
| 139 | (l)Solvent Cement 250ml |
| 140 | Add GST @ 18% for Sl No. 1-11 |
| 141 | Add CESS @ 1% for Sl No 1-11 Please Enable Macros to View BoQ information |