| 1 | Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint &provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3phase, 50 Hz, 4 wire system fabricated out of CRCA sheet up to 2 mm thick (1.6mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere , Volt , selector switches, frequency , phase indicating lamp, Energy complete including cost of busbar supports, detachable cable gland plates,2 earthing terminals, internal wiring &fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere , Volt , selector switch as per approved design & specification (Panel size: 750mm X 900mm X 300mm). |
| 2 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section,consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m. (for Panel MS stand weight) |
| 3 | Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint : One coat of red lead/Zinc chromate priming |
| 4 | 1st coat of synthetic enamel paint over the primer |
| 5 | Supplying and fixing 240/415V MCB Isolator on din rail of existing DBs and necessary connection. DP 40 A (Legrand) |
| 6 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection : SP: 6-32A (Make: Legrand) |
| 7 | Suppy of 240VAC Analog Timer Switch for On - Off control of street Light |
| 8 | Supply of 3Pole Power contactor type MNX18, 18A current rating |
| 9 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 10 | Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980) : 9m length, 147Kg, 410-SP-31 having Bottom dia. - 165.1mm x 4.5mm 05 m long, mid section 13 9.7mm x 4.50mm 02 m long and top section 114.3 x 3.65 mm 02 m long |
| 11 | Supply of CI base plate for overhead MS pole |
| 12 | Supply of CI pole CAP for overhead MS pole |
| 13 | Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly: Upto 9.0 mtr. Size 0.6x0.6x1.70 mts |
| 14 | Providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole |
| 15 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint : Upto 9.0 mtr. long pole: One coat of red lead/Zinc chromate priming |
| 16 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. Upto 9.0 mtr. long pole : 1st coat of aluminium paint over 1 coat of RO priming. |
| 17 | 2nd coat of aluminium paint over 1st coat |
| 18 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. (Make: Philips / Panasonic / Bajaj / Crompton) |
| 19 | Supplying of 1.1 KV. Grade PVC insulated Conductorof following cables (make: Polycab/ Gloster/Havells): 3 C X 4 Sqmm |
| 20 | Supplying andDrawing 1.1KV single core stranded 'FR' PVCinsulated& unsheathed singlecorestrandedcopperwire (Branda pproved by EIC) of thefollowingsizesintheprelaid polythenepipeandby theprelaidGI fishwireandmaking necy. connection as required [3 x 36/0.3 (2.5 sqmm)] |
| 21 | Supply of 1.1 KV grade XLPE insulated PVC Sheathed Aluminum conductor Armoured Cable 2 core 10 Sq.mm (Conforming to IS - 7098 (Part 1) : 1988). |
| 22 | Laying of one cable upto 50 Sq.mm through existing RCC / Hume / GI pipe / HDPE Pipe open masonary trench for single 2, 3.5 & 4 core. |
| 23 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required : 40mm dia |
| 24 | Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985 (Dia) [PE - 63] A. 6 Kg / Sq.Cm. (Working Pressure) (Dia) 40 mm |
| 25 | Labour for fitting and fixing high density poly-ethylene pipes or P.V.C. pipes for above ground work including cost of jointing materials paints etc. fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.)B. Under ground 40 mm dia. |
| 26 | Supply of G.I. Earth Spike of 1833 x 20mm |
| 27 | Erection/ fixing of G.I. Earth Spike of 1833 x 20mm |
| 28 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages : a) Solid GI wire iii) No. 6 SWG |
| 29 | Supply of GI bolt 10mm x 25mm with nuts, Check nuts, spring washers etc |
| 30 | Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect. |
| 31 | Providing CC (6:3:1) muffing 0.3 mtr dia upto the height of 0.3 mtr. above the ground level around the pole base complete with 3 mm thick neatly finished cement plaster all-round after dismantling the unserviceable muffing if necessary |
| 32 | Supply and Fixing of 2 mm Polyvinyl glow sign board madeof 22 SWG GI sheet box with 5”X12” aluminum channel for fixing the vinyl board after necessary cutting the letter asrequired & s\f LED tube light fittings along with all accessories.10x4 =40 |
| 33 | GST 18 % |
| 34 | Cess 1% Please Enable Macros to View BoQ information |