| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) etc., complete all as specified and as directed. |
| 2 | M&L for 75mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.finishing the surface even & smoth without using extra cement all as directed. |
| 3 | Dismantling of Stone sett paving/inetrlocking tiles of any description or thickness laid dry or laid dry and pointed and remove from MoD Land complete all as specified and as directed. |
| 4 | Supply and laying of 55 mm thick silicon moulded paver blocks of square shape with natural stone texture finish, made using high-strength concrete (M-30 grade or above), vibrated and compacted in precision moulds. The paver blocks shall have a uniform size and slip-resistant laying over 50 mm sand cushion all as completed as per Engineer-In-Charge. |
| 5 | Dismantling floor, hearth or wall tiles including cement mortar bedding (but not backing) and removing serviceable tiles to stores and rubbish off the premises etc., complete all as specified and as directed. |
| 6 | M&L Providing and laying vitrified parking tiles of sizes (600X600) of 15 mm thickness conforming to IS 15622 in all colors and shades in outdoor floors and skirting meant for parking of cars and trucks,set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 20mm thick screed bed in CM (1:4) etc., complete all as specified and as directed. |
| 7 | M&L for PCC Type B-0, 1:2:4 (12.5 mm Stone Aggregate) parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, kerb stop rounded or chamfered in edges complete all as specified and as directed. |
| 8 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Concrete, brick work, masonry, etc. complete all as specified and as directed. |
| 9 | Dismantling fencing wire mesh any type complete all as specified and as directed. |
| 10 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil complete all as specified and as directed. |
| 11 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and as directed. |
| 12 | S&F MS framed work such as fencing post including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 13 | M&L PVC coated GI chain link fencing 3.5mm dia with 50mm x 50mm mesh including fixing of MS line wire / rod, flat iron & machine made hexagonal or square head bolts to fencing posts complete all as specified.(supply only of MS rod and bolts will be measured and paid seperately) complete all as specified and as directed. |
| 14 | Supply only mild steel screw bolts n exc 12 mm dia machine made with hexagonal or square head at one end and screwed the other or screwed both ends for fixing of chain link fencing complete all as specified and as directed. |
| 15 | Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 16 | Demolition of precast concrete work built in cement mortar including all quoins arches pillars etc., complete all as specified and as directed. |
| 17 | M&L for Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc.10 cm in width and setting in cement mortar 1:6, etc., complete all as specified and as directed. |
| 18 | Taking down Cement Plaster of any description on PCC block walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. (Note :- Rate inclusive of necessary scaffolding up to a height of G+3 bldg all as directed). |
| 19 | M&L Rendering 15mm thick in fair faces of PCC block wall or concrete surfaces in CM(1:4) finished even & fair without using extra cement all as specified and directed.Note :- Water Proofing compound shall be paid separately |
| 20 | M&L for rendering 10mm thick plaster in fair faces of PCC block wall or concrete surfaces in CM (1:6) finished even & smooth without using extra cement complete all as specified and as directed. |
| 21 | Supply only Liquid water proofing compound ISI marked etc., complete all as specified and as directed. (Note : WPC may apply as per manufactures instructions or 3% by the wt of cement). |
| 22 | M & L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal esistance, dirt resistance exterior paint of WHITE colour with silicon additives coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm over new surfaces complete all as specified and as directed by Engineer-in-charge.Make: Asian Paints (Apex Ultima), Berger (Weathercoat Long Life Flexo) Nerolac (Excel Total), Shalimar Paints (Weatherpro+ Super Luxury Emulsion) |
| 23 | M&L proparing newly plastered surfaces of wall and applying two coats of high sheen, Anti-Fungal, Excellent Stain Resistant interior Acrylic emulsion paint over a coat of primer complete all as specified and as directed by Engineer-in-charge.Make: Asian Paints (Tractor uno), Berger (Bison Emulsion) Nerolac (beauty smooth). Shalimar Paints (No.1 Silk) |
| 24 | M&L Providing and applying putty of 1 mm thickness over plastered surface of wall/ceiling to prepare the surface even and smooth. |
| 25 | Dismantling Asbestos Cement Corrugated or Semicorrugate in Roof covering, complete all as specified and directed. |
| 26 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.(Note : Height of the bldg up to G+3 storey including necessary safety arrangements) |
| 27 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and as directed.(Note : Height of the bldg up to G+3 storey including necessary safety arrangements) |
| 28 | S&F Aluminium flat iron work in wind ties 40x6mm size fixed with 50mm/ 75 mm aluminium self staging screws with integral EPDM washer screwed in roof covering complete all as specified and as directed.(Note :- Height of the bldg up to 15 mtrs including necessary safety arrangements) |
| 29 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 30 | M&L for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. etc., complete all as specified and as directed. (Note :- Considered for Railing on balcony /staircase portion at any postition) |
| 31 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe.290.Gde-E-165 etc., complete all as specified and as directed. |
| 32 | M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment confirming to Fe 410 -W (Gde- E- 250) quality- A etc., complete all as specified and as directed. Please Enable Macros to View BoQ information |