| 1 | Dismantling of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/ rubbish off the premises etc complete all as specified and directed. |
| 2 | Brick work with fly ash (Old Size bricks) sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:4, complete all as specified and as directed. |
| 3 | Brick work with old unserviceable bricks retrieved from dismantling straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:4, complete all as specified and as directed. |
| 4 | Brick work with fly ash bricks (Old Size bricks), sub class'B' bricks straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4, complete all as specified and directed. |
| 5 | Brick work with old unserviceable bricks retrieved from dismantling straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4, complete all as specified and directed. |
| 6 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises, complete all as specified and directed. |
| 7 | 15mm thick rendering cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali-resistant priming paint, complete all as specified and directed. |
| 9 | Preparation of old plastered surfaces of walls and applying one coat of cement base paint over a coat of alkali-resistant priming paint, complete all as specified and directed. |
| 10 | Preparation of old plastered surfaces and applying one coat of exterior emulsion paint, 1st quality on kerb stones and walls, complete all as specified and directed. |
| 11 | Preparation of new plastered surfaces and aapplying two coats of exterior emulsion paint over a coat of chalk white, complete all as specified and directed. |
| 12 | Demolition of cement concrete (un-reinforced) of any description and in any position not specifically provided for, complete all as specified and as directed. |
| 13 | 60mm thick factory made machine pressed precast concrete, coloured interlocking paver block with cement and coloured pigment (topping thickness not less than 5mm thick with white cement and non-fadable epoxy coated colour pigment), any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-35 grade, complete all as specified and directed. |
| 14 | 80mm thick factory made machine pressed precast concrete, coloured interlocking paver block with cement and coloured pigment (topping thickness not less than 5mm thick with white cement and non-fadable epoxy coated colour pigment), any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-40 grade, complete all as specified and directed. |
| 15 | 75mm thick PCC 1:3:6 Type C-2 (40 mm graded stone aggregate) as insub-base of floors, sub-bases, floors, pavings etc., complete all as specified and directed. |
| 16 | 25mm thick sand cushion for laying interlocking paver block including watering and consiladation, complete all as specified and directed. |
| 17 | Dismantling existing undulated interlocking tile (paver) of any description / thickness incl sand cusion providing 75mm thick (avg thickness) PCC sub base 1 :4:8 type D-2 using 40mm graded stone aggregate ( to maintain with adjacent sub base top level) laying of old interlocking tiles (paver) using sand as cusion as per site condition, complete all as specifiled & directeted. |
| 18 | M&L cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in road side kerb stone chamfered on edgesincluding demolition and removing materials out side MoD & etc complete all as specified and directed |
| 19 | PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed. |
| 20 | PCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in surface channels and drains, complete all as specified and as directed. |
| 21 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for( reinforcement cut as required to facilitate demolition) and rubbish off the premises, complete all as specified and directed. |
| 22 | Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:6 including necessary moulds/ formwork, complete all as specified and directed. Note :- Reinforcement shall be measured and paid seperately under respective items. |
| 23 | TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed. |
| 24 | Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete including taking out embedded portion, making good disturbed ground and removal of rubbish complete all as specified and directed. |
| 25 | S&F in repairs galvanised 2 strand steel barbed wire 2.24 mm dia barded with 2mm dia wire at 75 mm spacing, straining and fixing to any type of standard rail, standard bolts including securing or tying at crossing with galvanized mild steel wire staple or steel pins complete all as specified and directed. Note: Each line of wire to be measured separately. |
| 26 | Dismantling of fencing wire mesh of any type and in any position by unscrewing nuts fillets, clamps etc complete all as specified and directed. |
| 27 | Supply only chain link fencing of 4.00mm dia galvanised steel oblong wire mesh size 50x50mm with weight not less than 4 Kg/Sqm, complete all as specified and directed. |
| 28 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. Note :- Supply of Galvanized steel wire chain link fecncing, Mild steel round bars, Mild steel flat iron, Nuts, Bolts & Washers will be measured and paid for separately. |
| 29 | Mild steel screw bolt (machine made) with hexagonal or square heads at one end, screwed the other or screwed both ends. Each screwed end to be fitted with two washers and one hexagonal or square nut exc 5 cm but not exc 10cm long (dia of shank 12mm) complete all as specified and directed. |
| 30 | Supply only 10 mm dia mild steel round bars as in stiffener to chain link fencing including necessary cutting bending etc. conforming to Grade-I, IS 432-2000 (Part-I) complete all as specified and as directed. |
| 31 | Framed work such as doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 32 | PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 33 | Demolition and breaking up of 300mm internal dia drain pipes (Saltglazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed. |
| 34 | 300mm bore reinforced cement concrete pipes, class NP2, laid and jointed complete with one collar per length of pipe, complete all as specified & directed. |
| 35 | Concrete bed to 150mm drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; in cement conctrete type C-2, 1:3:6, using 40 mm graded crushed stone aggregate, complete all as specified & directed. |
| 36 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed |
| 37 | Extra for forming fair finished drain or channel 60cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed |
| 38 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed. |
| 39 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 40 | Preparation of old painted steel or iron surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 41 | Preparation of new steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 42 | 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including demolition of old stone slab/tiles of any description, removal of rubbish complete all as specified and directed. |
| 43 | 18 to 20mm thick bhaislana zebra green marble work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including demolition old, complete all as specified and directed. |
| 44 | Precast cement concrete louvers and jallies, 35mm thick, type B-0 (1:2:4) 12.5mm graded aggregate, (measured solid), including all mouldings but excluding frame, set in CM 1:4 including demolition of old jallies and removal of rubbish beyond the premises, complete all as specified and directed. |
| 45 | 9 to 10 mm thick heavy duty Industrial tiles (sqaure/ rectangular), area of each tile exc 0.08 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over and including 15 mm thick screed bed or bedding layer mortar in CM 1:4 including dismantling of old tiles of any description with bedding layer of mortar and removal of rubbish complete all as specified and as directed. |
| 46 | Chequered coloured prepolished designer cement concrete tiles of size 300 x 300 x 25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 20mm thick screed bed in cement mortar 1:4, grouted flush and jointed in neat cement slurry including dismantling of old tiles of any description with bedding layer of mortar and removal of rubbish complete all as specified and as directed. |
| 47 | 40mm thick PCC 1:2:4 Type B-1 (20 mm graded stone aggregate) as in sub base of floors, sub-bases, floors, pavings etc., complete all as specified and directed. |
| 48 | Non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement over 15mm thick screed bed or bedding layer of mortar in CM 1:4 and dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding (but not backing), rubish off the premises, complete all as specified and directed. |
| 49 | Rolled mild steel in roof trusses (framed),trussed ,purlins,crane girders,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde-E-250) quality-A and painting one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication & broughting the same at site, complete all as specified and directed. |
| 50 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws and including dismantling old sheet as specified and directed. Please Enable Macros to View BoQ information |