| 1 | Demolition of brick work built in cement mortar including all quions, arcches, pillars etc complete all as specified and directed. |
| 2 | M&L for brick work in CM (1:6 ) with using flyash modular size brick straight or curved on plan exceeding 6.0mtr mean radius complete all as specified and directed. |
| 3 | Demolition of cement concrete in ground floor and paving not exceeding 15cm thick ( below or above ground level ) complete including removal of debries out side MD land complete all as specified and directed. |
| 4 | M&L for 25mm thick cement concrete (1:2:4) type B-0, using 12.5 mm graded stone aggregate for levelling course in floors complete all as specified and directed. |
| 5 | M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate, as in foundation filing, mass concrete, sub base of floor, etc complete all as specified and directed. |
| 6 | M&L for 75mm thick cement concrete (1:3:6) type C-1, using 20mm graded stone aggregate as in floor/ plinth protection finish the surface even and smooth with using extra cement including filling the expansion joints with bitumen filler / filler boards and necessary form work etc complete all as specified and directed. |
| 7 | Dismantling of floor, hearth, or wall tiling including cement mortar bedding ( but not backing ) and rubbish of the primeses complete all as specified and directed. |
| 8 | M&L for scratch free Glazed (Porcelain) Vitrified Tiles (GVT)/ Polished Glazed Vitrified Tiles (PGVT) 9 to 10mm thick (square or rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.72 sqm (i.e. size 600x1200 in floors & Skirting/Dado or all verticle surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile over and including 15mm thick screed bed or bedding layer in CM (1:6), complete all as specified and directed. Make of tile : Superior quality tiles from Kajaria/Somany/Orient Tiles/ or equivalent approved by GE. Note : (a) Size and pattern / texture of GVT (Matt Finish) / PGVT(Glossy Finish) shall be approved by GE. (b) Glazed Coating on GVT / PGVTshall not be less than 1mm thick . |
| 9 | M&L for scratch free Vitrified Tiles 9 to 10mm thick (square or rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.36 sqm i.e.size 600x600mm in floors & Skirting/Dado or all verticle surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile over and including 15mm thick screed bed or bedding layer in CM (1:6), complete all as specified and directed. Make of tile : Superior quality tiles from Kajaria/Somany/Orient Tiles/ or equivalent approved by GE. |
| 10 | M&L for non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 11 | M&L for glazed ceramic coloured tiles area of each tile exceeding 0.06 sqm not exceeding 0.16 sqm as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over and 10 mm thick backing coat on fair faces of brick work in CM (1:6) complete all as specified and directed. |
| 12 | Demolition of Stone slabs and tiles of any description or thickness in floors complete all as specified and directed. |
| 13 | M&L for chequered cement concrete tiles with grey cement and pigment of size 300mm X 300mm X 30mm thick, set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 14 | M&L for chequered cement concrete tiles with grey cement and pigment of size 400mm X 400mm X 40mm thick, set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 15 | M&L for machine cut kota stone slab in flooring 20 to 25mm thick laid over and including 15mm thick screed bed in CM (1:6) & cement mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed. |
| 16 | M&L for 18 to 20 mm thick green marble of approved quality of any size set and jointed in grey cement slurry laid over and including 15 mm thick screed bed in CM (1:4) including granite polish to be done by mechanical grinder and moulding edges compete all as specified and directed. |
| 17 | M&L for 18 to 20 mm thick Black granite slab of approved quality of any size bedded and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 15 mm thick screed bed in CM (1:4) including granite polish to be done by mechanical grinder and moulding edges complete all as specified and directed. |
| 18 | M&L for 60mm thick rubber moulded precast concrete interlocking paver block (glossy finish) of M-35 grade of approved shape, size and colour conforming to IS 15658-2006 including joints filled with sand and stone dust 25m thick as in levelling course of interlocking complete all as specified and directed. |
| 19 | M&L for 80mm thick rubber moulded precast concrete interlocking paver block (glossy finish) of M-40 grade of approved shape, size and colour conforming to IS 15658-2006 including joints filled with sand and stone dust 25m thick as in levelling course of interlocking complete all as specified and directed. |
| 20 | S&F precast cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate as in kerb and edging to road and footh path, etc including chamfered, weathering, throating etc and setting in CM (1:4), complete all as specified and directed. |
| 21 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) n. exc 1.50 Sqm each and removing from site complete all as specified and directed. |
| 22 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 Sqm but n. exc 4.00 Sqm each and removing from site complete all as specified and directed. |
| 23 | Taking down shutters of any description exc 1.00 Sqm and n.exc 2.00 Sqm each and removing from site complete all as specified and directed. |
| 24 | S&F 35mm thick factory made 2nd class hard wood plain, framed pannelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board wiyh commercial veneering on both faces. The size of rail and stile as per (IS : 1003 part-I) , kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 25 | S&F 35 mm thick factory made, 2nd class hard wood glazed and skeleton shutters open rebeated and prepared to received glass, gauzed, with out sash bar edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as per specified in SSR Part-I Section 8, clause 8.24 (a) and for door and fixed with chowkats, chemically pressure treated complete all as specified and directed. |
| 26 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of plain 5mm plain colour PVC sheet reinforced with ms square tube, with wooden grain printed PVC sheet used inserted of plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed. |
| 27 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of ms tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed. |
| 28 | S&F factory made 25 mm thick 100% solid WPC (wood polymer composite) laminated flush door shutter of required size comprising of virgin PVC resin of K value 57-60 ( suspension grade), Calcium carbonate and natural fibers ( Wood powders / rice husk/wheat husk) and non toxic additives made from extension process WPC foam sheet single extruded (Inner) with having minimum density not less than 650 kg kg/cbm, an ISO 9001-2015 certified company, having good screw holding capacity (Screw withdrawal strength of 200 N (Face) & 1100 N (Edge) minimum compissive of 50 N/mm2 Modulus of elasticity 850N/mm2 and resistance of spread of flame of class A category property of being Termite/ borer free, water/ moisture proof and fire retardant WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixing stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws including necessary Locking arrangement complete all as specified and as directed by the Engineer-In-charge. Note : (a) Colour/Texture Style of Door/Prelam Sheet shall be approved by GE (b) Test certificate from original Manufactuer shall be provided before incorporation in the work site. |
| 29 | S&F factory made 100% solid WPC (Wood polymer composite) Door frame 90mm X 45mm (Moulded) single rebated made from wood polymer composite (single extruded process material comparison of virgin PVC polymer of k value 57-60 (Suspension grade), calcium carbonate and natural fibers (Wood powder/rice husk/wheat husk) and Non toxic additives fabricated with meter joints after applying PVC solvent cement & screwed with full body treaded star headed screws having minimum frame density of 750 kg/ cbm, an ISO 9001-2015 certified company, having good screw holding capacity (screw withdrawal strength of (Min 990 N ), minimum compressive strength of 58 N/mm2, Modulus of elasticity 900N mm2 and resistance to spread of flame of class A category with property of being Termite/borer proof, water/ moisture proof and fire retardant & fixed with position with SS dash fasteners / Hold fast of required dia and length, all as per specifications drawings as directed by the Engineer-In-charge.Note : (a)Colour/Texture Style of Door/Prelam Sheet shall be approved by GE. (b)Test certificate from original Manufactuer shall be provided before incorporation in the work site. |
| 30 | S&F Powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed/Glass and one shutter wire mesh) with following specification complete all as specified and as directed by Engineer-in-charge.(i) Windows frame of cross section 101mm x 44mm (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm (iii) Sliding shutter frame of cross section 40 x 18mm(iv) 4 mm thick glass superior quality. (Min)(v) IDPE Rubber guasket for fixing of glass.(vi) Locking cleats per shutter -01 Nos. (Min)(vii) Sliding rollers per shutter - 02 Nos. (Min)(viii) Stainless steel wire cloth 0.30mm nominal dia of wire and average width of aperture 1.40mm for shutters 01 Nos. Note : (a) The thickness of the aluminium section shall be minimum of 2 to 3 mm. The final thickness and cross-section of the aluminium sections, required as per site conditions, shall be subject to approval by the Engineer-in-Charge, without any extra cost to the department.(b) The drawings and sizes of the windows shall be provided by the Engineer-in-Charge during execution of the work, as per actual site requirements. |
| 31 | S&F Anodised aluminium sliding glazed windows with three track shutter sliding (two shutters glazed/Glass and one shutter wire mesh) with following specification complete all as specified and as directed by Engineer-in-charge.(i) Windows frame of cross section 101mm x 44mm (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm (iii) Sliding shutter frame of cross section 40 x 18mm(iv) 4 mm thick glass superior quality. (Min)(v) IDPE Rubber guasket for fixing of glass.(vi) Locking cleats per shutter -01 Nos. (Min)(vii) Sliding rollers per shutter - 02 Nos. (Min)(viii) Stainless steel wire cloth 0.30mm nominal dia of wire and average width of aperture 1.40mm for shutters 01 Nos. Note : Note : (a) The thickness of the aluminium section shall be minimum of 2 to 3 mm. The final thickness and cross-section of the aluminium sections, required as per site conditions, shall be subject to approval by the Engineer-in-Charge, without any extra cost to the department.(b) The drawings and sizes of the windows shall be provided by the Engineer-in-Charge during execution of the work, as per actual site requirements. |
| 32 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 33 | S&F powder coated aluminum door with the following specification and making good the adjacent surfaces, complete all as specified and directed.(a) Cross section of chowkhat frame 101.60x44.45mm(b) Cross section of hanging and meeting style 83x44mm(c) Top rail of cross section 114x44mm(d) Bottom rail of cross section 114x44 mm (e) Locking rail (middle rail) of cross section 83x44 mm(f) 4 mm thick glass superior quality. (Min)(g) Aluminum handle eisc type -02 Nos per shutter (inside & out side).(h) Aluminum door stopper heavy duty-01 Nos per shutter. (i) Aluminum tower bolt 200mm long-01 Nos per shutter (inside).(j) Concealed Lock with key superior quality makae and type as approved by GE openable both from inside & out side -01 Nos per shutter. Note : Note : (a) The thickness of the aluminium section shall be minimum of 2 to 3 mm. The final thickness and cross-section of the aluminium sections, required as per site conditions, shall be subject to approval by the Engineer-in-Charge, without any extra cost to the department.(b) The drawings and sizes of the doora shall be provided by the Engineer-in-Charge during execution of the work, as per actual site requirements. |
| 34 | S&F in repairs stainless steel wire cloth of 0.36mm dia wire and average width of aperture 1.4mm & fixed with tacks of stainless steel wire staples,etc complete all as specified and directed. |
| 35 | Hacking out old broken glass ( any tickness size ,quality or description ) from wooden frame or stone etc and S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beading in square not exceeding 0.50 sqm in each panes complete all as specified and directed. |
| 36 | S&F 100 mm Butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed. |
| 37 | S&F 150 mm long Aluminum anodized barrel tower bolts of extructed section complete all specified and directed. |
| 38 | S&F 50 mm long aluminum anodized alloy handles fabricated complete all as specified and directed. . |
| 39 | S&F in repairs 200 mm long Aluminium alloy anodised sliding door bolt with hasp staple (bolt type) including fixing clips of sheet, cast or extruded section and fixing bolts and 16mm dia bolt sliding bolts of extruded section complete all as specified and directed. |
| 40 | Taking down existing aluminium Door/window shutters of any size and carry out minor repairs with & including replacement of unserviceable top/bottom rail, hinges, rubber beading, etc and also carry out repalcement of broken wire mesh and glass panes wherever necessary and refixing the shutter in the same opening complete all as specified and directed.Note : Wire mesh and glass pan shall be measured and paid separatly. |
| 41 | S&F factory made PVC shelf/partition of required size consisting of panel of 18 mm thick celuka PVC ply having prelaminated one side on it of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company , using solvent cement etc, complete all as specified and directed.Note : Design, Size, Colour and Texture of PVC ply shall be approved by Engineer in charge. |
| 42 | S&F in repairs 25 mm dia of anodised aluminium alloy, chromium plated drappery curtain rod with fixing bracket complete all as specified and directed. Please Enable Macros to View BoQ information |
| 43 | S&F in repairs 25 mm dia of anodised aluminium alloy, chromium plated drappery curtain rod with fixing bracket complete all as specified and directed. Please Enable Macros to View BoQ information |