| 1 | Taking down carefully copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed. |
| 2 | Taking down carefully electrical accessories by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed. |
| 3 | M&L for surface point wiring for one light point or fan/exhaust point controlled by one switch with with 1.5 Sqmm PVC insulated FRLS, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC casings & capings /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as and continuous earth lead cable wire of similar description of wiring cable complete all as specified and directed. Note:-(i) Wiring cable shall be provided using colour coding such as Phase - Red, Neutral – Black, and Earth – Green or as approved by Engr-in-charge . |
| 4 | All as per item No. 3 above but point wiring for one Call Bell point controlled by one bell push button switch. |
| 5 | All as per item No. 3 above but point wiring for one 5 Amp socket point on independent board controlled by one switch and with 2.5 Sqmm wiring cable. |
| 6 | All as per item No. 3 above but point wiring for one 3 pin ,5 Amp socket point on the same board with other switch and 2.5sqmm wiring cable. |
| 7 | All as per item No. 3 above but point wiring for 15/16A socket outlet with 2.5 Sqmm wiring cable. |
| 8 | M&L for concealed point wiring for one light point or fan/exhaust point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor (stranded) 1100 volt wiring cable in & including ISI marked PVC conduit of size not less than 20mm, ivory/white in colour with all accessories (such as tee, bend, joint cover etc) including suitable size modular metal boxes with cover plate along with frame for mounting of switches/sockets/ regulator etc and continuous earth lead cable wire of similar description of wiring cable complete all as specified and directed. Note:-(i) Wiring cable shall be provided using colour coding such as Phase - Red, Neutral – Black, and Earth – Green or as approved by Engr-in-charge .(ii) Cutting, chasing in walls (brick or stone) shall be measured and paid separately under respective item here-in-before. |
| 9 | All as per item No. 8 above but point wiring for one Call Bell point controlled by one bell push button switch. |
| 10 | All as per item No. 8 above but point wiring for one 5 Amp socket point on independent board controlled by one switch and with 2.5 Sqmm wiring cable. |
| 11 | All as per item No. 8 above but point wiring for one 3 pin ,5 Amp socket point on the same board with other switch and 2.5sqmm wiring cable. |
| 12 | All as per item No. 8 above point wiring for one 2-way light point controlled by 2- two way switches. |
| 13 | All as per item No. 8 above but point wiring for 15/16A socket outlet with 2.5 Sqmm wiring cable. |
| 14 | S&F Modular switch, one way, 5/6 Amp 230, 1 module complete all as specified and directed. |
| 15 | S&F Modular switch, two way, 5/6 Amp 230, 1 module complete all as specified and directed. |
| 16 | S&F Modular socket outlet, 5/6 Amp-2/3 pin combined, 2 module complete all as specified and directed. |
| 17 | S&F switch Modular, single pole, one way,15/16 Amp ,1 module 230 Volt complete all as specified and directed. |
| 18 | S&F socket outlet modular 15/16 Amp, 5/6 pin combined ,2 module 230 Volt complete all as specified and directed. |
| 19 | S&F modular fan step regulator 60/80W, 2 module complete all as specified and directed. |
| 20 | S&F modular bell push, 6Amp, 1 module complete all as specified and directed. |
| 21 | S&F switch piano flush type, single pole, one way 5 A 230 V complete all as specified and directed. |
| 22 | S&F socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed. |
| 23 | S&F switch piano type flush, single pole, one way 15 A 230 V complete all as specified and directed. |
| 24 | S&F socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V complete all as specified and directed. |
| 25 | S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.. |
| 26 | S&F lamp holder insulated with back plate suitable for Angle/Batten fitting, complete all as specified and directed. |
| 27 | S&F in repair/replacement bell ding dong 230 V, single phase, complete all as specified and directed. |
| 28 | S&F electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed. |
| 29 | S&F bell push flush type one way 5Amp 240 Volt complete all as specified and directed. |
| 30 | M&L concealed sub main wiring with two single core 6.0 Sqmm PVC FRLSH insulated unsheathed stranded copper cable (Phase & neutral) and one single core cable of same description as continuous earth wire, drawn in & incl medium grade, ISI marked PVC conduit of suitable size (not less than 20mm dia) with all accessories (such as tee, bend, joint cover, round / square blocks at junctions as required) complete all as specified and directed.Note: (i) The cost of cutting chases pinning for concealed PVC conduit, making good in CM 1:3 and painting so as to match with the adjoining existing surface finish shall be measured and paid separately under respective item of BOQ in this contract)(ii) Proper colour coding of wiring cables (as approved by Engg-in-charge) shall be used/ ensured(iii) Two runs of single core cable (Phase and neutral) and one run of single core cable (earth continuity conductor) & one run of PVC casings & capings/pvc conduit shall be measured as one unit length. |
| 31 | M&L surface sub main wiring with two single core 6.0 Sqmm PVC FRLSH insulated unsheathed stranded copper cable (Phase & neutral) and one single core cable of same description as continuous earth wire, drawn in & incl medium grade, ISI marked PVC casings & capings /conduit of suitable size (not less than 20mm dia) with all accessories (such as tee, bend, joint cover, round / square blocks at junctions as required) complete all as specified and directed.Note: (i) Proper colour coding of wiring cables (as approved by Engg-in-charge) shall be used/ ensured(ii) Two runs of single core cable (Phase and neutral) and one run of single core cable (earth continuity conductor) & one run of PVC casings & capings/pvc conduit shall be measured as one unit length. |
| 32 | M&L surface sub main wiring with two single core 4.0 Sqmm PVC FRLSH insulated unsheathed stranded copper cable (Phase & neutral) and one single core cable of same description as continuous earth wire, drawn in & incl medium grade, ISI marked PVC casings & capings /conduit of suitable size (not less than 20mm dia) with all accessories (such as tee, bend, joint cover, round / square blocks at junctions as required) complete all as specified and directed.Note: (i) Proper colour coding of wiring cables (as approved by Engg-in-charge) shall be used/ ensured(ii) Two runs of single core cable (Phase and neutral) and one run of single core cable (earth continuity conductor) & one run of PVC casings & capings/pvc conduit shall be measured as one unit length. |
| 33 | M&L surface sub main wiring with two single core 4.0 Sqmm PVC FRLSH insulated unsheathed stranded copper cable (Phase & neutral) and one single core cable of same description as continuous earth wire, drawn in EXISTING PVC/ STEEL conduit of suitable size (not less than 20mm dia) with all accessories (such as tee, bend, joint cover, round / square blocks at junctions as required) complete all as specified and directed.Note: (i) Proper colour coding of wiring cables (as approved by Engg-in-charge) shall be used/ ensured(ii) Two runs of single core cable (Phase and neutral) and one run of single core cable (earth continuity conductor) & one run of PVC casings & capings/pvc conduit shall be measured as one unit length. |
| 34 | S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250MM including taking down existing exhaust fans of any description, type a and size including disconnection of electric connections and deposited to AGE E/M store yard complete all as specified and directed.Make : Havells Model -Thrill Air DX HS / Crompton: model- BRISK AIR NEO /equivalent make in bajaj / philips |
| 35 | Supply & fix Wall mounted fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting. |
| 36 | S&F MCB SP 240 volt 6 Amp to 32 Amp 10 KA capacity having C-curve characteristics complete all as specified and directed. |
| 37 | S&F MCB SPN 240 volt 40 Amp 10 KA capacity having C-curve characteristics complete all as specified and directed. |
| 38 | S&F MCB SPN 240 volt 63 Amp 10 KA capacity having C-curve characteristics complete all as specified and directed. |
| 39 | S&F MCB SP 240 volt 6 Amp to 63 Amp 10 KA capacity having C-curve characteristics complete all as specified and directed. |
| 40 | S&F sheet metal enclosure distribution board (DB) double door, IP-43, TPN, 4 way, 415 V with 200 Amps rated bus bar of suitable size, including taking down existing DB with MCB and bus bars complete all as specified and as directed.Note :- The cost of cutting and chasing in stone masonry and making good to disturbed surfaces shall deemed included in quoted unit rate . |
| 41 | S&F MCB TPN 415 volt 63 Amp 10 KA capacity having C-curve characteristics complete all as specified and directed. |
| 42 | S&F sheet metal enclosure distribution board (DB) double door, IP-43, SPN, 12 way, 415 V with 200 Amps rated bus bar of suitable size, including taking down existing DB with MCB and bus bars complete all as specified and as directed.Note :- The cost of cutting and chasing in stone masonry and making good to disturbed surfaces shall deemed included in quoted unit rate . |
| 43 | S&F sheet metal enclosure distribution board (DB) double door, IP-43, SPN, 8 way, 415 V with 200 Amps rated bus bar of suitable size, including taking down existing DB with MCB and bus bars complete all as specified and as directed.Note :- The cost of cutting and chasing in stone masonry and making good to disturbed surfaces shall deemed included in quoted unit rate . |
| 44 | S&F sheet metal enclosure distribution board (DB) double door, IP-43, SPN, 4 way, 415 V with 200 Amps rated bus bar of suitable size, including taking down existing DB with MCB and bus bars complete all as specified and as directed.Note :- The cost of cutting and chasing in stone masonry and making good to disturbed surfaces shall deemed included in quoted unit rate . |
| 45 | S&F in repair 2' X 2' ultra slip recess mounted luminaire with high brightness 36 Watt LED package and Unique pattern acrylic de-glaring diffuser sheet for glare-free uniform light distribution suitable for suspended false ceiling grid complete all as specified and directed. |
| 46 | S&F in repair LED Bulk head luminaire, 13 watt, designed for modern homes available in PIR as well as non PIR sensor with premium quality diffuser for glare free light and easy to install snap fit installer complete all as specified and directed. |
| 47 | S&F Tube light fitting 20/18 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directedMake : Havells - Cat no LHEXAPP7PN1W020/ Bajaj - Beam Pro Batten 830412 Philips -Ujjwal/ slimline Batten 919515814053 Orient - LBLN -18-C-SQ Please Enable Macros to View BoQ information |
| 48 | S&F Tube light fitting 20/18 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directedMake : Havells - Cat no LHEXAPP7PN1W020/ Bajaj - Beam Pro Batten 830412 Philips -Ujjwal/ slimline Batten 919515814053 Orient - LBLN -18-C-SQ Please Enable Macros to View BoQ information |