| 1 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts all as specified and directed by Engr-in-Charge. |
| 2 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide, exceeding 1.5 m depth and not exc. 3.0 m in depth for taking out / laying of under ground cable in trenches or cable ducts all as specified and directed by Engr-in-Charge. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified and directed by Engr-in-Charge. |
| 4 | Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : punned thickness shall be measured for payment purpose all as specified and directed by Engr-in-Charge. |
| 6 | Supply & lay brick of conventional size 230x110x75mm locallly available as protection of cable in trenches complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L PCC 1:4:8 type D2 using graded stone aggregate for foundationof pole complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate for filling of pole &stay complete all as specified and directed by Engr-in-Charge . |
| 9 | M&L PCC 1:2:4 type B2 using 20mm graded stone aggregate for coping of pole complete. |
| 10 | Labour charges for re-laying of serviceable bricks of any size and type recovered during taking out of old cable , over newly laid or re-laid cables complete all as specified and directed by Engr-in-Charge.. |
| 11 | M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for 50mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for 80mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for 100mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified and directed by Engr-in-Charge. |
| 15 | Taking down or out existing cable of sizes 2/3.5/4 core 16 sqmm to 240 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester) , stacking and rolling unserviceable cable for further disposal all as directed by Engr in charge. Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid separately under respective item of this schedule all as specified and directed by Engr-in-Charge. |
| 16 | Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 16sqmm 4 core including necessary cable lugs, glands, insulation tape and deposited to MES store yard complete all as specified and directed by Engr-in-Charge. |
| 17 | Description all as per ser item No 16.00 above, but of size 16 sqmm 2 core. |
| 18 | Description all as per ser item No 16.00 above, but of size 25 sqmm 4 core. |
| 19 | Description all as per ser item No 16.00 above, but of size 35 sqmm 3.5 core. |
| 20 | Description all as per ser item No 16.00 above, but of size 50 sqmm 3.5 core. |
| 21 | Description all as per ser item No 16.00 above, but of size 70 sqmm 3.5 core. |
| 22 | Description all as per ser item No 16.00 above, but of size 95 sqmm 3.5 core. |
| 23 | Description all as per ser item No 16.00 above, but of size 120 sqmm 3.5 core. |
| 24 | Description all as per ser item No 16.00 above,e but of size 185 sqmm 3.5 core . |
| 25 | M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 16sqmm x 4 core cables including testing& commissioining complete all as specified and directed by Engr-in-Charge. |
| 26 | Description all as per ser item No 25.00 above, but of size 25 to 50sqmm x 3.5 / 4 core, as per the size of existing UG cable. |
| 27 | Description all as per ser item No 25.00 above, but of size 70 to 120 sqmm x 3.5 core, as per the size of existing UG cable. |
| 28 | M&L LT indoor/outdoor end joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty cables with aluminium conductor including jointing kit, including making joints for the cable of size 150/185 sqmm x 3.5 core cables including testing and commissioining complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L LT indoor/outdoor end joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty cables with aluminium conductor including jointing kit, including making joints for the cable of size 240-300 sqmm x 3.5 core cables including testing and commissioining complete all as specified |
| 30 | Supply & replace 250 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed by Engr-in-Charge. |
| 31 | Supply & replace 250 A 3 pole MCCB, 36 KA , 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed by Engr-in-Charge. |
| 32 | Supply & replace 200 A 3 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable type of thermal setting including necessary cable lugs & wire etc complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply & replace 100 A 3 pole MCCB, 16KA , 415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete all as specified and directed by Engr-in-Charge. |
| 34 | Supply & replace 63 A TP MCCB, 16 KA, 415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete all as specified and directed by Engr-in-Charge. |
| 35 | Supply & replace digital type Ammeter 96X96 mm square Flush mounted case of class 1.0 complete all as specified and directed by Engr-in-Charge. |
| 36 | Supply & replace digital type Voltmeter 0-500V, 96X96 mm square Flush mounted case of class 1.0 complete all as specified and directed by Engr-in-Charge. |
| 37 | Supply & replace CT 400 - / 5A, 200/5A or 100/5A for ammeter complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion. |
| 39 | S&F in repairs decorative garden light (landscape lighting) made up of high grade unbreakable polycarbonate materials of capacity 9W LED complete all as specified and directed. Make : Bajaj Cat Part No BGBOM 650 9W LED (Tulip) or equivalent/Havells/CROMPTON. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) The contractor should include the rates for PCC as required and nut bolts for fixing the light in quotated rate, complete all as specified and directed by Engr-in-Charge. |
| 40 | Taking out old unserviceable steel tubular/RCC poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle all as specified and directed by Engr-in-Charge. |
| 41 | M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Alluminium painting will be done on pole above 1.5 Mtr height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint (30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed by Engr-in-Charge. |
| 42 | Supply and installation of off load change over switch in sheet metal enclosure of capacity 4P 63 Amps,complete all as specified and directed by Engr-in-Charge. |
| 43 | Supply and installation of on load change over switch in sheet metal enclosure of capacity 4P 100 Amps, complete all as specified and directed by Engr-in-Charge. |
| 44 | Supply and installation of on load change over switch in sheet metal enclosure of capacity 4P 200 Amps, complete all as specified and directed by Engr-in-Charge. |
| 45 | S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front having 6000 lumen/60 watts output mounted on MCPCB in gress protection IP-66 complete all as specified and directed by Engr-in-Charge. |
| 46 | S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front having 9000 lumen/90 Watts output mounted on MCPCB in gress protection IP-66 complete all as specified and directed by Engr-in-Charge. |
| 47 | Supply and fixing in replacement of LED driver suitable for upto 6000 lumen lumanaries complete all as specified and directed by Engr-in-Charge. |
| 48 | Supply and fixing in replacement of LED driver suitable for upto 9000 lumen lumanaries complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F in repair of 1.5 sqmm 3 core pvc insulated flexible copper conductor wire from street light terminal box to fittings of required length drawn through and including PVC conduit of suitable size or as indicated and complete all as specified and directed by Engr-in-Charge. |
| 50 | Supply and fix cable junction boxes in repairs of IP 66 protected “halogen free and weather proof” suitable for out door type (with metric knockouts for cable entry) of size 250 x 250 x 160 mm incl 01 No MCB SP 6 amp and having backelite connecting terminals mounted on saddles suitable for 3 phase with neutral system - 04 Nos of suitable length and thickness and connecting the incoming & out going LT cable connections in the terminal block of junction box and fixing clamps made up of GI flat of size 20 x 3 mm of suitable length-02 Sets, incl GI nut and bolt and washers on poles complete all as specified and directed by Engr-in-Charge. |
| 51 | Taking down ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repair, complete all as specified and directed by Engr-in-Charge. |
| 52 | Opening the unserviceable/ burnt fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed by Engr-in-Charge. |
| 53 | Supply and replacing of Ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed by Engr-in-Charge. |
| 54 | Supply and replacenment gun metal bushes of surface size for ceiling fan/ceiling fan incl necessary mechanical work, complete all as specified and directed by Engr-in-Charge. |
| 55 | Supply and replacing of cord cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply and replacing electronic step type fan regulator 240 Volt, 50 C/S, five step, suitable for 1200/1400mm sweep ceiling fan,complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply and Fix Capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed. |
| 58 | Supply and Fix Capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 59 | Supply for replacement ceiling fan blade set of three heavy duty suitable for 1200/1400mm sweep of suitable approved make as direcetd by Engr-in-Charge. |
| 60 | Supply and Fix PVC canopy for ceiling fan 1200/1400mm sweep complete for various makes/model of fan, complete all as specified and directed by Engr-in-Charge. |
| 61 | Disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair,complete all as specified and directed by Engr-in-Charge. |
| 62 | M&L for Strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed by Engr-in-Charge. |
| 63 | Description all as per ser item No 62.00 above, but of 300mm sweep. |
| 64 | Ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed by Engr-in-Charge. |
| 65 | Servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed by Engr-in-Charge. |
| 66 | Supply and fiixing Heating element for geyser of cap 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells |
| 67 | Supply and fixing Heating element for geyser of cap 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/Bajaj/havells |
| 68 | Supply and fixing Thermostat for Geyser of capacity 25/35/50 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus |
| 69 | Geyser Syphon Assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, complete all as specified and directed. |
| 70 | Description all as per ser item No 69.00 above, but for 35 Ltr capacity. |
| 71 | Description all as per ser item No 69.00 above, but for 50 Ltr capacity. |
| 72 | Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed by Engr-in-Charge. |
| 73 | Taking down old unserviceable plug top from geyser connection and Supply and Fixing in replacement plug top 15/16 Amps for Geyser, complete all as specified and directed. |
| 74 | PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. Make:- Havells / Plaza |
| 75 | Supply and replacement of safety valve for geyser of 25/35/50 litre capacity, complete all as specified and directed by Engr-in-Charge. |
| 76 | Supply and replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed by Engr-in-Charge. |
| 77 | Supply and replacement of heavy duty PVC connector 300mm long 15mm dia with PTMT nut for geyser of 25 / 50 litre capacity, complete all as specified and directed. Make- Prayag |
| 78 | Disconnecting and taking out geyser of capacity 25 litre and replacement of SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed by Engr-in-Charge. |
| 79 | Description all as per ser item No 78.00 above, but for 35 Ltr capacity. |
| 80 | Description all as per ser item No 78.00 above, but for 50 Ltr capacity. |
| 81 | Taking down old unserviceable and supply & fixing stop cock brass 15mm dia not less than 420 grams, complete all as specified and directed. |
| 82 | Supply and fixing of geyser Bolt 100 mm Long with nut & washers, complete all as specified and directed |
| 83 | Supply and fixing Sensor board suitable for water geyser 25/35 Ltr Capacity of Make Venus Model - 25 RD/35RD. |
| 84 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |