|
| 1 | Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed. |
| 2 | M&L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 4 | Taking down cement plaster on brick or stone wall etc. including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 5 | Supply only WPC, complete all as specified and as directed. |
| 6 | M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces, finished fair and even on walls in cement mortar (1:6), complete all as specified. |
| 7 | Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer over plastered surfaces of walls complete all as specified. |
| 8 | Material & Labour for complete removal of existing treatment, preparation of surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer of walls to prepare the surface even and smooth complete all as specified. |
| 9 | M&L for rendering 5mm thick on fair faces of ceiling / chajja concrete surfaces in cement mortar 1:3 complete all as specified & directed. |
| 10 | M&L for preparing old decorated plastered or unplasterd surfaces of ceiling by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper, rectifying minor cracks and undulations using Acrylic Wall Putty and primer to achieve a smooth, even surface. and applying two coats of white wash on ceiling complete all as specified and as directed. |
| 11 | M&L for prepartion of newly plastered ceiling/chajja surfaces and applying three coat of white wash complete all as specified and directed. |
| 12 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and as directed. |
| 13 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed. |
| 14 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet trip of 20mm with stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing complete all as specified and directed. |
| 15 | S&F 100 mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-22,complete all as specified and directed. |
| 16 | S&F aluminium anodised 150 mm barrel tower bolts of extruded section complete all as specified and directed. |
| 17 | S&F 150 mm long extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 18 | S&F in repairs Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed. |
| 19 | M&L for 4mm thick figured glass, pin head type and glazing with oil putty in square n. exc 0.5 sqm in each pan for bathrooms/toilets ventilators all as directed. |
| 20 | M&L for 100 mm thick cement concrete Type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub bases with nominal reinforcement complete all as specified and directed. |
| 21 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 22 | M&L Non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors laid over 15mm thick 1:6 cement mortar screed bed etc. set and jointed in neat cement slurry and pointed in white of coloured cement to match complete all as specified and directed. |
| 23 | M&L Glazed ceramic coloured tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all complete all as specified and directed. |
| 24 | M&L for Rendering 10 mm thick in CM 1:4 finished even and fair on vertical surfaces on wall to receive wall tiles,complete all as specified and directed. |
| 25 | S&F Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 conforming to Fe-290, Gde-E-165 the grill shall be inseted in the wall surface including necessary drilling and grouting with cement etc, complete all as specified and directed. |
| 26 | M&L for preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 27 | M&L Non Skid ceramic coloured tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors/skirting etc. laid over 15mm thick 1:6 cement mortar screed bed set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 28 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished fair and event complete all as specified and directed with using water proofing compound. Note: WPC measure separetly. |
| 29 | Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm ) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified. |
| 30 | M & L for preparation of old surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 31 | M & L for preparation of old painted steel and iron surfaces of any description exc 10 cm width or girth and applying TWO coat of synthetic enamel spray paint over a coat of red oxide complete all as specified and directed. |
| 32 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge |
| 33 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-chargeher for openable/sliding shuttters) including all necessary fittings as directed |
| 34 | S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but n.exc 0.5 sq.m in each pane complete all as specified and as directed. |
| 35 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed. |
| 36 | M&L for RCC 1:1.5:3 type A1 (20 mm graded crushed stone aggregate) nominal mix as in chajja complete all as specified and directed. |
| 37 | M&L for use and waste of fair finish formwork to sides of chullah hoods, chajjas complete all as specified and directed. |
| 38 | M&L for RCC 1:1.5:3 type A1 (20 mm graded crushed stone aggregate) nominal mix as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed. |
| 39 | M&L for prepartion of old surface and applying two coats of Super Latex (Sika or equivalent) @ 80gm per sqm per coat in the ratio of 1:1.5:5 (latex : water : cement) over internal/external of brick/concrete surface after cleaning and washing the surface by wire brush and plenty of water The entire surface shall be washed throughly with plenty of water and then allowed to dry complete all as specified and as directed. Note:- The entire process to be executed through authorised applicator. |
| 40 | M&L for RCC 1:1.5:3 type A1 (20 mm graded crushed stone aggregate) nominal mix as in slabs supported on walls, beams and columns, in roofs, landings,deck slab and in shelves and the like complete all as specified and directed. |
| 41 | M&L for use and waste of fair finish formwork for sofits of slab complete all as specified and directed. |
| 42 | M&L Plain Cement Concrete 1:3:6 type C1 (using 20 mm stone aggregate) as in surface channels and drains, complete all as specified and directed. |
| 43 | S&F in repair CP Bib taps 15mm dia, with cfancy handle, screwed down, screwed for iron pipe or for brass ferrule, fency type and fixed complete all as specified and directed. |
| 44 | S&F in repair Stop valve cast copper alloy screwed down high pressure with capston headed handle chromium plated concealed type screwed both ends for pipe 15 mm bore or for unions complete all as specified and as directed. |
| 45 | S&F in repair angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and as directed. |
| 46 | S&F in repair soap dish, any type fixed to plugs chromium plated brass screws complete all as specified and as directed. |
| 47 | S&F in repair wall mounted mixer for Bathroom, made of brass, chrome polish finish, without hand shower, complete all as specified and as directed. |
| 48 | S&F in repair glass self assembly consisting of 5.5 mm thick glass sheet glass self 12 Cm wide with CP bracket gaurd and railing 60 Cm long complete all as specified and as directed. |
| 49 | S&F in repair chromiuim plated Swivel shower roses with shower arm, 125 mm size including fxing to steel pipe or union etc complete all as specified and as directed. |
| 50 | S & F in repairs vitreous china squatting pan, 'Orissa\\" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing , connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 51 | S&F in repairs PVC valveless,syphonic action type, low level PVC flushing cistren 10 ltr cap white with flush pipe & all fitting complete all as specified. |
| 52 | S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 53 | S&F in repairs grating square, Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms), complete all as specified and directed. |
| 54 | Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 55 | Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 56 | S&F 16 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 57 | S&F 20 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 58 | S&F in repairTubular towel rail, 20mm dia, D type, brass chromium plated, 60cm long between flanges complete all as specified and directed. |
| 59 | Supply & fix in repairs mirror 600mmx 400mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 60 | S&F PVC plain bend (any radius) for 75 mm bore, PVC pipes, complete all as specified and directed. |
| 61 | S&F 75mm bore PVC (SWR) junction single, (single T) equal or unequal fitted with oval access door, complete all as specified and directed. |
| 62 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including dismantling old unserviceable existing pipe with fittings, complete all as specified and directed.[Note : Payment shall be made in net length as fixed between the fittings as per SSR Part-II preamble para (a) of Page 384.] |
| 63 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including dismantling old unserviceable existing pipe with fittings, complete all as specified and directed. |
| 64 | S&F PVC (SWR) bends, plain, 110 mm bore any radius, complete all as specified and directed. |
| 65 | S&F 110 mm bore PVC (SWR) junction single (single T) equal or unequal fitted with oval access door, complete all as specified and directed. |
| 66 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 and cutting chases for concealed water tubing and making good of groves for concealed GI tube, cutting not exc 10cm girth complete all as specified and as directed. |
| 67 | M & L for (a) providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry with acrylic based modified cementitaous composite compound coating of make as approved in technical instruction 5/2003 (b) First layer of slurry of cement @ 0.5 Kg/Sqm mixed with acrylic based polymer modified cementatious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours. (c) second slurry of cement @ 0.500 Kg/Sqm mixed with acrylic based polymer modified cementatious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (d) 200 micron thick polythene film pasted with the help of bituminous adhesive shall be provided over treatment. |
| 68 | M&L for repair to crack portion with jacktting technuque, taking down existing plaster up to brick wall surface of min 200 mm wide, cleaning to loose particles on surface of brick work along the length of crack and filling the gap/crack area with PCC 1:1.5:3 type A0 using 12.5 mm aggregate up to brick surface and inserting the welded mesh of size 25 x 25x 2 mm dia along the crack on both side of the wall surface fixed with, drilling holes 10 mm dia on either side of the crack by means of drilling machine through out the full width of the wall @ 25 cm c/c and insert 8/10 mm dia rod in the drilled holes, welded with horizontal rod to with hold the welded mesh and applying grit plaster 1:1:2 using 4 mm and down aggregate finished even and smooth without using extra cement complete all as specified and directed. |
| 69 | S&F for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as spd and directed. |
| 70 | S&F for solid PVC Wall Lining consisting of 5mm thick single side prelam colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as spd and directed. |
| 71 | M&L for 25 mm thick PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregate) as in floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed. |
| 72 | M&L Non Skid coloured ceramic tiles 7 to8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cemeent to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in CM 1:6 complete all as specified and directed. |
| 73 | M&L Non Skid coloured ceramic tiles 7 to8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm on vertical surface such as skirtings etc. set and jointed in cement slurry over 10 mm thick rendering in CM 1:3 complete all as specified and directed.complete all as spd and as directed. |
| 74 | M&L for Glazed ceramic tiles Coloured 350 x 250mm/450 x 300mm 7 to 8 mm thick in wall/dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match rendering over 10 mm thick in CM 1:3 on stone masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces complete all as specified and directed. |
| 75 | S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.Fe 410-W (Gde-E-250) quality A complete all as spd and directed. |
| 76 | M&L 4mm thick any colour ACP board (Aluminium composite panel), exterior grade, (approved colour) fixed with aluminium tapperd clip to aluminium frame work all as specified and as directed. |
| 77 | S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty. |
| 78 | S&F for stainless steel entrance main glass door pipe pull handle (length 18\\", hole to hole size 14\\" ) with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, with suitable arrangement complete all as specified and directed |
| 79 | S&F for 4mm thick sheet glass, ordinary and glazing with aluminium beading in aluminium frame in square exc 0.5 sqm in each pane all as specified and as directed. Please Enable Macros to View BoQ information |