| 1 | Material and labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping bed blocks, etc including weathering, slightly rounded or chamfered angles and necessary form work complete all as specified and as directed . |
| 2 | Taking down chowkhats or frame with shutters (without taking off shutters from frames) not exc 1.5 Sqm each incl holdfasts from wall and making good in cement mortar 1:4 complete in all respect as specified and directed. |
| 3 | Material & Labour for Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length completeas specified and directed. |
| 4 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed ounter sunk S.S screws, all as specified and directed. . (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 5 | Supply and Fixing 75 mm Butt hinges, medium weight cold rolled, mild steel and fixed complete all as specified and as directed |
| 6 | Supply and Fixing 100mm long cast type anodised aluminium handle complete in all respect as specified and directed. |
| 7 | Supply and Fixing 250mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete in all respect as specified and directed. |
| 8 | Material and labour for Plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in 75mm thick sub base to floor or similar items complete all as specified and as directed. |
| 9 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block, rubber moulded of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drives ways or light traffic parking etc., of required strength thickness and size/shape, made by table vibratory method using over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of interlocking paver blocks in to the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 10 | Providing and laying cement concrete, 100mm thick 1:2:4 type B2 (using 40 mm nominal size crushed and graded aggregate) for laying floor finish, finished fair and even complete in all respect as specified and directed. |
| 11 | Material and labour for 15 mm thick rendering in CM (1:6) over wall surface of any description and finishe the surface even and smooth without using extra cement including taking down of existing rendering complete all as specified and directed |
| 12 | Material and labour for preparation of new plastered surfaces of wall and applying 1.5mm thick Birla or equivalent wall putty and applying two coats of oil bound distemper over a coat of alkhali resistant priming paint complete all as specified and directed. |
| 13 | Material and labour for complete removal of existing treatment of wall surfaces and applying 1.5mm thick Birla or equivalent wall putty to old plastered surface and applying two coats of oil bound distemper complete all as specified and directed. |
| 14 | Material and labour for prepartion of old ceiling surfaces and applying two coats of oil bound distemper complete all as specified and directed. |
| 15 | Material and labour for preparation of old decorated painted wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint duly filled the voids with enamel based putty complete all as specified & directed. |
| 16 | Supply and Fixing acrylic sheet, 8mm thick fixing to each WPC shutter after cutting the shutter and paste with suitable strong adhesive, duly filled the joints and covering joints with beading complete all as specified and directed. |
| 17 | Taking down carefully unserviceable main switches/DB's off size including MCBs from their position and removing materials from site all as specified and as directed . |
| 18 | Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed. |
| 19 | Supply and Fixing sub main wiring in PVC casing capping min 25 mm dia with 2 single core10 sqmm FRLSH multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 10 sqmm copper conductor cable connected to common earth dolly complete and including PVC casing capping all as specified and as directed .(Note 1. two run (phase and neutral) of 10 sqmm and one run earth wire of 10 sqmm will be measured as 1 RM.2. Rate quoted by contractor is inclusive of rate of making good the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed. |
| 20 | S & F sheet metal enclosure Double Door factory made distribution board 240 volts SPN 12 way, 200 Amps rated bus bar complete all as specified and as directed. Note- Rate quoted by contractor is inclusive of rate of making good the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed. |
| 21 | Material and labour for MCB SPN 6 to 32 Amps, C Curve, 240 volts, 50 Hz AC supply complete all as specified and directed. |
| 22 | Material and labour for MCB SP 06 to 32 Amps, C Curve, 240 volts, 50 Hz AC supply complete all as specified and directed. |
| 23 | Supply and Fixing Vertical Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCCBs 415 volts with 200 Amps rated bus bar,VTPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directedNote : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate |
| 24 | Supply and fixing MCCBs 415V, 16KA, 4 Pole capacity 63 amp |
| 25 | Supply and Fixing Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 415 volts with 200 Amps rated bus bar,TPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed.Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate quoted. |
| 26 | Supply and Fixing MCB 63 Amps, 440 Volt AC supply Triple pole with neutral(TPN) C curve with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed |
| 27 | Material and labour for Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains complete all as specified. |
| 28 | Taking down Re-fixing existing XLPE cable any size and any capacity ,removing and re-fixing electric connection with thimbal in VTPN DB on wall complete all as specified and directed . |
| 29 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including flatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed. (Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner) . |
| 30 | Material and labour for removing normal earthing and commissioning, installation and testing of maintenance free UL approved chemical earthing with copper earth plate electrode 90cm x 60cm x 5 mm thick buried directly in ground vertically at a depth not less than 4.2 metre below normal ground level with top edge of earth plate at a depth not less than 3 meter below normal ground level, earth plate covered with LHOM Earth enhancing chemical compound (Bentonite powder) all around the plate upto 30 cm and electrode connections by using copper strip of 32 x6 mm as earthing lead (upto the test point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 80mm dia GI pipe filled with earth enhancing chemical compound connected to main switch board or main control board including RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR part 1 complete all as specified and as directed . Make JMV LPS Ltd/ OBO/ENNOV Infra solutions Pvt. Ltd/ erico /powerbolt. |
| 31 | Demolition of un-reinforced cement concrete in ground floor and pavings not exceeding 15 cm thick (below or above ground level) and removing all the rubbish complete all as specified and directed |
| 32 | Demolition of stone slabs, tiles and paver blocks of any description or thickness, laid bedded and pointed in any mortar complete all as specified and as directed. |
| 33 | Taking down electric meter for repair/serviceing of any make and any type model, sealing, cable end with tape,and re-fixing the meter with electric connection ,complete all as specefied and as directed. |