| 1 | Surface excavation not exceeding 30 cm and averaging 15 cm deep and getting out in soft/loose soil including removing green vegetation, roots, bushes,etc from surrounding of LT feeder Boards/Poles/substations etc complete all as specified. |
| 2 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 3.0 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed. |
| 3 | All as per item no 2 above but exceeding more than 1.5 m in depth |
| 4 | Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil. |
| 5 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at a level not exceeding 1.5 mtr above the starting point. |
| 6 | Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and leveling complete, all as specified.Note:-(i) Consolidated/punned sand shall be considered for purpose of payment.(ii) Sand shall be same as specified for plastering work. |
| 7 | Taking up or down 10 sqmm 2 core worn out/ damaged / partially serviceable/unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors 1100 volt grade from trench including taking out unserviceable bricks,pipes etc testing of cable in the presence of Engr-in-charge to ascertain seviceability,seggregating serviceable and unserviceable cable and keeping in safe custody the serviceable portion for reuse, stocking serviceable bricks for reuse complete all as specified and directed(Note: Earth work shall be measured and paid separately under relevant item of BoQ ). |
| 8 | All as per item No. 07 here-in before but for cable of size 4 core 10 sqmm. |
| 9 | All as per item No. 07 here-in before but for cable of size 4 core 16 sqmm. |
| 10 | All as per item No. 07 here-in before but for cable of size 4 core 25 sqmm. |
| 11 | All as per item No. 07 here-in before but for cable of size 4 core 35 sqmm. |
| 12 | All as per item No. 07 here-in before but for cable of size 3.5 core 95 sqmm. |
| 13 | All as per item No. 07 here-in before but cable of size 3.5 core 185 sqmm. |
| 14 | All as per item No. 07 here-in before but cable of size 3.5 core 300 sqmm. |
| 15 | All as per item No. 07 here-in before but cable of size 3.5 core 500 sqmm. |
| 16 | Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 2.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately |
| 17 | All as per item No. 16 here-in before but cable of size 4 core 10 sqmm. |
| 18 | All as per item No. 16 here-in before but for cable of size 4 core 16 sqmm. |
| 19 | All as per item No. 16 here-in before but for cable of size 4 core 25 sqmm. |
| 20 | All as per item No. 16 here-in before but for cable of size 4 core 35 sqmm. |
| 21 | All as per item No. 16 here-in before but for cable of size 3.5 core 95 sqmm. |
| 22 | All as per item No. 16 here-in before but cable of size 3.5 core 185 sqmm. |
| 23 | All as per item No. 16 here-in before but cable of size 3.5 core 300 sqmm. |
| 24 | All as per item No. 16 here-in before but cable of size 3.5 core 500 sqmm. |
| 25 | Laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 - 95 sqmm 4/3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note for item no 25 to 27 :- UG cable will be issued under Sch `B' free for fixing/laying from AGE E/M (N) Patiala (ii) Excavation, Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately |
| 26 | All as per item No. 25 here-in before but of size 3.5 core 120-150 sqmm. |
| 27 | All as per item No. 25 here-in before but of size 3.5 core 185-240 sqmm. |
| 28 | M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge. |
| 29 | M&L for Dismantling cross-arms of M.S. channel or angle sections etc from LT poles complete all as specified and directed by Engineer in Charge. |
| 30 | M&L for Cross arms bracing supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shapes or sizes as indicated or directed and inclusive of one primer coat,one under coat and one finishing coat of paint. |
| 31 | M&L for Painting to existing PCC pole of any type with Black and yellow synthetic enamel paint over existing paint up to 1.5 m height from bottom alternatively strips 30 cm each including painting of ,clamps, nut, bolts with aluminum paint including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as directed by Engr-in-Charge. |
| 32 | M&L for Painting to existing steel tubular pole of any type complete with two coat of aluminium synthetic enamel paint from bottom to top of the pole inculding black and yellow paint upto 1.5 Mtr height from bottom alernaterely strip 30 cm each including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete upto the entire satisfaction of Engr-in-Charge. |
| 33 | M&L for Painting existing LT panel board of any type complete with two coat of weather proof synthetic enamel spray paint over a coat of red oxide primer after preparation of the surface complete all as directed by Engr-in-Charge. |
| 34 | Supply and fix in repair chain link fencing with post and door frame arrangement for LT panel/two pole structure/four pole structure/etc of height 4 feet complete all as specified and directed by Engineer-in-Charge |
| 35 | M&L for streching and tightning of existing ACSR conductor any size on LT pole 9 mtr long all as specified (one span consists of 5 ACSR conductors 1 earth wire and cradle guard) includind replacement of J hooks complete all as specified. |
| 36 | M&L for replacement of shackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 100mm height and 115 mm dia including galvanized mild steel straps of section 38 x 5 mm size ,20 mm dia bolt nut and washers complete all as specified and directed . |
| 37 | Supply and fix LT spacer 02 way FIX type made out of PVC material and suitable to work on 1100 volts fixed between 02 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.Make : Denson,Modern,Sintex |
| 38 | Supply and fix LT spacer 04 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 04 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.Make : Denson,Modern,Sintex |
| 39 | Supply and fix LT spacer 05 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 05 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.Make : Denson,Modern,Sintex |
| 40 | Supply and fix cable lugs aluminium any type suitable for cable up to 70 sqmm including necessary crimping with crimping tool complete all as specified and directed . |
| 41 | All as per item no 40 but of size up 95 -120 sqmm |
| 42 | All as per item no 40 but of size up 150 - 185 sqmm |
| 43 | All as per item no 40 but of size up 240 - 300 sqmm |
| 44 | M&L for replacement existing worn out /over heated/ multi-jointed ACSR jumpers of LT over head lines with and incl XLPE/PVC insulated 1100 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral incl winding with ACSR conductors with suitable size aluminium binding wire complete all as specified and directed . (Length of one jumper not exceeding more than 2.0 mtrs . |
| 45 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 46 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 47 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 100 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 48 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 49 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 50 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 51 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 52 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 53 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 54 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S |
| 55 | Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white ,with letters and conventional skull and bone in postal red color and fixed with flat iron clamps, nuts, bolts , and washers of size 200mmx 150 mm for LT complete all as directed.Note : (Note:-the printing shall be hand written only stancils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width .) |
| 56 | Demolition of concrete of any description and in any position not otherwise specially provided for complete all as directed by Engineer –in- Charge |
| 57 | Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI strip of size 25X4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work, GI pipe light grade 25mm/40 mm bore for protection of GI wire /strip from earth electrode to and incl the supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I and connected to earth test point incl testing complete all as specified and directed |
| 58 | M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed. |
| 59 | M&L for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in mass concrete in foundations etc complete all as specified and directed . |
| 60 | Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified |
| 61 | Meterial and labour for making locking provision to the LT panel board of any size/type by providing MS flat iron 25x6 mm up to lengh 15cm duly welded to the both front and back door duly holed for making provision for lock including welding of brocken/unserviceable hinges/mounting arrangements of doors and matching with enamel paint of existing colour on the disturbed surfaces and providing pad lock not less than 75mm with triplicate key complete all as specified and directed by Engr-in-Chrage. Make of pad lock: Harrison/Navta/Godrej |
| 62 | Supply,laying,galvanised steel tubing light grade complete ith all fitting of size 40 mm dia for cable protection along with pole across road etc. Complete all as specified and directed by Engr-in-Charge. |
| 63 | All as per item Ser No 62 above but size of pipe 80 mm dia |
| 64 | Supply and fix in repairs, installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory fabricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 800 amp marked red, yelllow, black and blue mounted on inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete with following accessories:- Note:- Approval of panel drawing must obtained from AO before placing the order and PCC shall be measured and paid separately INCOMING:- (a) MCCB 400 Amps microprocessor based with adjustable thermal and magnetic 415 Volts,36KA, 4 pole.-01 No. OUT GOING:- (a) MCCB 100 Amps with adjustable type 4 pole 415 Volts, 25 KA - 8 Nos (b) Digital type Volt meter 0-500 Voltssquare type with selector switch - 01 No.(c) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(d) Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(f) Cable glands brass of suitable size for cable. |
| 65 | Supply and fix in repairs, installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory fabricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 600 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete with following accessories:- Note:- Approval of panel drawing must obtained from AO before placing the order and PCC shall be measured and paid separately. INCOMING:- (a) MCCB 400 Amps microprocessor based with adjustable thermal and magnetic 415 Volts,25KA, 4 pole.-01 No. OUT GOING:- (a) MCCB 63 Amps with adjustable type 4 pole 415 Volts, 16 KA -5 No (b) Digital type Volt meter 0-500 Voltssquare type with selector switch - 01 No.(c) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(d) Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(f) Cable glands brass of suitable size for cable. |
| 66 | Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory fabricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 630 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete with following accessories:- Note:- Approval of panel drawing must obtained from AO before placing the order and PCC shall be measured and paid separately INCOMING:- (a) MCCB 400 Amps microprocessor based with adjustable thermal and magnetic 415 Volts,36KA, 4 pole.-01 No. OUT GOING:- (a) MCCB 250 Amps with adjustable type 4 pole 415 Volts, 25 KA -02 Nos & MCCB 160 Amps with adjustable type 4 pole 415 Volts, 16 KA -01 Nos (b) Digital type Volt meter 0-500 Voltssquare type with selector switch - 01 No.(c) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(d) Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(f) Cable glands brass of suitable size for cable. |
| 67 | Supply and fix in repairs, installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory fabricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 1200 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete with following accessories:- Note:- Approval of panel drawing must obtained from AO before placing the order and PCC shall be measured and paid separately INCOMING :ACB Microprossessor relese based type 50Hz, 4 Pole 800Amp 50 KA,with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE-01No. OUT GOING:- (a) MCCB 400 Amps with adjustable type 4 pole 415 Volts, 36KA - 2 Nos (b) Digital type Volt meter 0-500 Voltssquare type with selector switch - 01 No.(c) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(d) Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(f) Cable glands brass of suitable size for cable. |
| 68 | Suppy and fix rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |
| 69 | Supply and fixing junction box of size 300 mm x 200 mm x 105 mm, made out of FRP sheet with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Apms MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed. |
| 70 | Supply and fixiing PVC insulated round/flat copper cable of size 3 core, 2.5 Sqmm for connection of LED lights from FRP junction box to street light fitting complete all as specified and directed. |
| 71 | Boring of holes under road, pavement, hard standing without cutting suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed. |
| 72 | Supply and fix in repairs erecting in true verticle position of steel tublar pole 9 Mtrs long complete with cast iron base plate finial taper plug bolt nuts and screws as as specified and of type 410 SP-31 conforming to relevent IS including two coats of aluminium paint over aone coat of red oxide primer to the full length of the pole and also two coats of bituminus paint inside outside of bottom portion upto 1.5 mtrs length and provide circular bend 32 mm dia 1 Nos of length 2 mtrs duly fixed with necessary clamp for mounting LED security light all as specified and directed by Engr-in-Charge. Note:- Excavation and PCC shall be measured and paid separetaly. |
| 73 | Material and labour for Periodical cutting of trees /trimming of branches along the LT overhead lines in a girth of 03 mtrs on either side of the conductors including removing the same and dumping complete all as directed by Engr-in-Charge. Note : Expenditure for necessary tool and plants required for Periodical cutting of trees / trimming of branches along the HT /LT overhead lines are deemed to be included in rate quoted by the contractor. |
| 74 | Special Notes for above schedule of work:- (i) External electrification services are of being emergency work. The site work arranged to contractor shall commence within 10 days and any further delay shall be resulted in penality as decided by AO.(ii) Contractor has to take upmost care to avoid damage to existing lines/structure during the excution of work.(iii) Contractor has to ensure the proper safety of his team to avoid any mishappening at site of work , if any mishappening occures the contractor will be held solely responsible for the same. Please Enable Macros to View BoQ information |