| 1 | Servicing of DG set 250 KVA including replacement of following parts, alignment of Alternator, Minor reapir and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed. Make of DG Set- Cummins. (spares, lube oil and coolant shall be measured and paid separately under respective items of BoQ here-in-after):- |
| 2 | Supply only Filter kit comprising of Air, Fuel and oil filters to be incorporated in Srl Item No 1.00 above all as specified and directed. |
| 3 | Supply only Fan Belt as per sample to be incorporated in Srl Item No 1.00 above.all as specified and directed. |
| 4 | Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed |
| 5 | Servicing of DG set 160 KVA including replacement of following parts, alignment of Alternator, Minor repair and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed. Make of DG Set- Mahindra & Mahindra. (spares, lube oil and coolent shall be measured and paid separately under respective items of BoQ here-in-after) |
| 6 | Supply only Filter kit comprising of Air,Fuel and oil filters to be incorporated in Srl Item No 5.00 above all as specified and directed. |
| 7 | Supply only Fan Belt as per sample to be incorporated in Srl Item No 5.00 above all as specified and directed. |
| 8 | Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed |
| 9 | Servicing of DG set 125 KVA including replacement of following parts, alignment of Alternator, Minor repair and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed. Make of DG Set- Kirloskar/ Cummins/ Ashoka Layland. ( spares, lube oil and coolent shall be measured and paid separately under respective items of BoQ here-in-after):- |
| 10 | Supply only Filter kit comprising of Air,Fuel and oil filters to be incorporated in Srl Item No 9.00 above all as specified and directed. |
| 11 | Supply only Fan Belt as per sample to be incorporated in Srl Item No 9.00 above all as specified and as directed. |
| 12 | Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed |
| 13 | Servicing of DG set 40 to 63 KVA (MES No- i- 263/6005/DG,AL/05, ii-263/6098/DG/16, iii- 715/6010/DG/06, iv- 261839W, NYA ) Make- Cummins/ Kirloskar) including replacement of following parts alignment of Alternator, Minor repair and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed (spares shall be measured and paid separately under respective items of BoQ here-in-after):- |
| 14 | Supply only Filter kit comprising of Air,Fuel and oil filters to be incorporated in Srl Item No 13.00 above all as specified and directed. |
| 15 | Supply only Fan Belt as per sample to be incorporated in Srl Item No 13.00 above all as specified and directed. |
| 16 | Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed. |
| 17 | Servicing of DG set 25 KVA (MES No- 263/6043/DG/AL/06, 02 Nos NYA) (Make- Kirloskar) including replacement of following parts alignment of Alternator, minor work and complete checking of fuel pump after necessary inspection of DG set complete all as specified and directed (spares shall be measured and paid separately under respective items of BoQ here-in-after):- |
| 18 | Diesel filter kit to be incorporated in Srl Item No 17.00 above. all as specified and as directed. |
| 19 | Oil filter kit to be incorporated in Srl Item No 17.00 above all as specified and directed. |
| 20 | Fan belt as per sample to be incorporated in Srl Item No 17.00 above all as specified and directed. |
| 21 | Dismantling Self Starter assy of DG of capacity 25 kVA including necessary repairs/ calibration and reassembling the same after repair all as specified and directed. |
| 22 | Supply & filling and topping up Engine oil of suitable grade 15W40 for above mentioned different capacity DG set all as specified and directed. |
| 23 | Supply & replace Coolant for Radiator for above mentioned different capacity DG set all as specified and directed. |
| 24 | Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 63Amp all as specified and directed.. |
| 25 | Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 100Amp all as specified and directed.. |
| 26 | Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 125Amp all as specified and directed. |
| 27 | Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 200Amp all as specified and directed.. |
| 28 | Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 400Amp all as specified and directed.. |
| 29 | Supply and replace power contactor AC 415 volt, operating coil -230 volts, four pole type MCX 31 and 40 including auxiliary contacts 1NO+1NC suitable for AMF panel complete all as specified and directed . |
| 30 | Supply and replace power contactor AC 415 volt, operating coil -230 volts, four pole type MCX 33 including auxiliary contacts 1NO+1NC suitable for AMF panel complete all as specified and directed . |
| 31 | Supply and replacement of AMF panel auto start relay/ voltage monitering relay as per existing and with copper conductoer wiring of AMF panel with suitable size wire complete all as sample of existing relay complete all as specified and directed . |
| 32 | Labour only for complete calibration of AMF Panel of capacity 40 to 75 KVA, checking all functioning state of components, cleaning of contactor links with suitable cleaning material with and including minor repairs, insulation, tightening of control wiring cables,copper lugs complete all as specified and directed |
| 33 | Labour only for complete calibration of AMF Panel of capacity 125 to 250 KVA, checking all functioning state of components, cleaning of contactor links with suitable cleaning material with and including minor repairs, insulation, tightening of control wiring cables,copper lugs complete all as specified and directed |
| 34 | Material and labour for painting by using spray painting method for DG set canopy/ complete body/ LT panel board (After removing incoming/out going electrical connection and refixing the same) with two coats of superior quality synthetic enamel paint after cleaning of existing surface, removing rust including marking of incoming/ outgoing feeder with letters, MES/ SM Nos complete and all as specified and directed. |
| 35 | Supply & install in repair Lead Acid Battery 12 V 180 AH complete all as specified and directed. |
| 36 | Supply & install in repair Lead Acid Battery 12 V 150 AH complete all as specified and directed. |
| 37 | Supply & install in replacement of Battery Charging unit 24V, 250 kVA DG set complete all as specified as per existing cat part/ sample. |
| 38 | Supply & install in replacement of Battery Charging unit 24 V, 160 kVA DG set complete all as specified as per existing cat part/sample. |
| 39 | Supply & install in replacement of Battery Charging unit 24 V, 125kVA DG set complete all as specified as per existing cat part/sample. |
| 40 | Supply & install in replacement of Battery Charging unit 12 V, 75 kVA DG set complete all as specified as per existing cat part/sample. |
| 41 | Supply & install in replacement of Battery Charging unit 12V, 40kVA DG set complete all as specified as per existing cat part/sample. |
| 42 | Supply & install in replacement of Inverter/ UPS 1500 VA complete all as specified and directed. |
| 43 | Supply and fixing in replacement of digital Voltage regulator unit of AMFpanel of DG Set 25 kVA to 125 KVA capacity as per existing type and model all as specified and directed. |
| 44 | Supply and fixing in replacement of digital Voltage regulator unit of AMFpanel of DG Set 160kVA to 250 KVA capacity as per existing type and model all as specified and directed. |
| 45 | Supply and replacing complete hose pipe set with clamps for DG sets of capacity 25 KVA to 100 KVA as per existing type and size all as specified and directed. |
| 46 | Supply and replacing complete hose pipe set with clamps for DG sets of capacity 125 KVA to 250 KVA as per existing type and size all as specified and directed. |
| 47 | Supply and fixing inreplacement exhaust assembling for 25 kVA DG set as per existing type and model all as specified and directed. |
| 48 | Supply and fixing in replacement exhaust assembling for 125 kVA to 250kVA DG set as per existing type and model all as specified and directed. |
| 49 | Material & Labour Dismantling the alternator of DG set of capacity 25 KVA to 125 kVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop by crane and vehicle, opening into parts, checking all winding like main starter/ rotor winding, exciter starter/ rotor winding. Rewinding the main rotor and exciter rotor by using the \\"F\\" class insulation and existing gauge and type of magnet wire that was on the original motor, varnishing, heating, drying, greasing the bearings including replacement of unserviceable bearings, Re-fixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site, Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on \\"OFF/FULL LOAD\\", matching to the existing range of RPM of the engine, out put voltage 415 volt and testing all as specified and directed. |
| 50 | Material & Labour Dismantling the alternator of DG set of capacity 125 KVA to 250 kVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop by crane and vehicle, opening into parts, checking all winding like main starter/ rotor winding, exciter starter/ rotor winding. Rewinding the main rotor and exciter rotor by using the \\"F\\" class insulation and existing gauge and type of magnet wire that was on the original motor, varnishing, heating, drying, greasing the bearings including replacement of unserviceable bearings, Re-fixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site, Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on \\"OFF/FULL LOAD\\", matching to the existing range of RPM of the engine, out put voltage 415 volt and testing all as specified and directed. |
| 51 | Taking down self starter assembly 12 volt of DG set 25kVA to 100kVA from the existing position, opening in to parts, sort out the unserviceable items like carbon brush, pinion etc. and replace the same with new one including rewinding of field coils, re-assembling and re-fixing the same in its original position including to and from conveyance charges to work shop and testing and all as specified and directed. |
| 52 | Taking down self starter assembly 24 volt of DG set 125kVA to 250kVA from the existing position, opening in to parts, sort out the unserviceable items like carbon brush, pinion etc. and replace the same with new one including rewinding of field coils, re-assembling and re-fixing the same in its original position including to and from conveyance charges to work shop and testing and all as specified and directed. |
| 53 | Taking down water pump assembly from the existing position, opening into parts overhauling the same with replacement of water pump repair kit, ball bearing (1No) water pump, gasket seal, oil seal and re-assembling and re-fixing on the base for the capacity 25kVA to 100 KVA DG sets and all as per the direction of the engr-in-charge. |
| 54 | Taking down water pump assembly from the existing position, opening into parts overhauling the same with replacement of water pump repair kit, ball bearing (1No), water pump, gasket seal, oil seal and re-assembling and re-fixing on the base for the capacity 125kVA to 250 KVA DG sets and all as specified and directed. |
| 55 | Taking down the Dynamo 12/24 Volts from the existing position, shifting to the work shop and back , opening into parts, cleaning to sort out the unserviceable parts, replace by new one, rewinding and varnishing, heating of coil, reassembling and re-fixing to its base including to and from conveyance charges for work shop to the site for any capacity of DG and all as specified and directed.. |
| 56 | Dismantling fuel injection pump (FIP) of DG set capacity 25 to 250 KVA carefully, opening in to parts, for maintenance, servicing, tuning by overhauling and calibration up to 6 cylinders, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-fixing the FIP on its original position including to and from conveyance charges to the work shop and all as specified and directed. |
| 57 | Supply & Fix in repair CONTROL & AMF PANEL BOARD for 125 KVA DG Set all as specified and directed.Note (i) The control panel is manufactured with 16/18 guage CRCA sheet and is powder coated for a weather proof and long lasting finish. The control panel/AMF panel consists of Microprocessor based DES 9 electronics controller, MCCBs of suitable rating, Key switche, Push button (Starter), LED battery charging alternator fail indication, current transformer, instrument fuses, Sound proof and weather proof encosure with safety features.(ii) KWH meter 3 phase, 415 volt and 63 Amp capacity - 01 Nos(iii) Volt meter 0-50 volt with rotary selector switch 3 ways flush typs - 01 Nos(iv) Ampere meter 0-100 flush type with rotary switch 3 ways - 01 Nos(v) Indicating lamp RYB - 03 Nos(vi) The AMF panel consist Key switcyhes/Auto start Generator set controller, Multy functional meter displaying Current and Voltages. |
| 58 | Supply & Fix in repair CONTROL & AMF PANEL BOARD for 160 KVA DG Set all as specified and directed.Note (i) The control panel is manufactured with 16/18 guage CRCA sheet and is powder coated for a weather proof and long lasting finish. The control panel/AMF panel consists of Microprocessor based DES 9 electronics controller, MCCBs of suitable rating, Key switche, Push button (Starter), LED battery charging alternator fail indication, current transformer, instrument fuses, Sound proof and weather proof encosure with safety features.(ii) KWH meter 3 phase, 415 volt and 63 Amp capacity - 01 Nos(iii) Volt meter 0-50 volt with rotary selector switch 3 ways flush typs - 01 Nos(iv) Ampere meter 0-100 flush type with rotary switch 3 ways - 01 Nos(v) Indicating lamp RYB - 03 Nos(vi) The AMF panel consist Key switcyhes/Auto start Generator set controller, Multy functional meter displaying Current and Voltages. |
| 59 | Supply & Fix in repair CONTROL & AMF PANEL BOARD for 250 KVA DG Set all as specified and directed.Note (i) The control panel is manufactured with 16/18 guage CRCA sheet and is powder coated for a weather proof and long lasting finish. The control panel/AMF panel consists of Microprocessor based DES 9 electronics controller, MCCBs of suitable rating, Key switche, Push button (Starter), LED battery charging alternator fail indication, current transformer, instrument fuses, Sound proof and weather proof encosure with safety features.(ii) KWH meter 3 phase, 415 volt and 63 Amp capacity - 01 Nos(iii) Volt meter 0-50 volt with rotary selector switch 3 ways flush typs - 01 Nos(iv) Ampere meter 0-100 flush type with rotary switch 3 ways - 01 Nos(v) Indicating lamp RYB - 03 Nos(vi) The AMF panel consist Key switcyhes/Auto start Generator set controller, Multy functional meter displaying Current and Voltages. |
| 60 | Supply & Fixing LED flood Light comprising of aluminium die cast body housing, IP 66 light with high power LED's as light source suitable for architectural features or retail space of capacity 120 Watts (not less than 100 lumen/watt output) including bracket (as per manufacturer's instructions) for mounting flood lights with suitable clamps and nut and bolts and washers etc including connecting from pole/ box to street light all as specified. |
| 61 | Supply & Fixing LED security Light comprising of aluminium die cast body housing, IP 66 with high power LED's as light source suitable for roads, play ground etc of capacity 120 Watts with lance (not less than 100 lumen/ watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified. |
| 62 | Supply & Fixing LED security Light comprising of aluminium die cast body housing, IP 66 with high power LED's as light source suitable for roads,play ground etc of capacity 90 Watts with lance (not less than 100 lumen/ watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified. |
| 63 | Supply & Fixing LED security Light comprising of aluminium die cast body housing,IP 66 with high power LED's as light source suitable for roads,play ground etc of capacity 60 Watts with lance (not less than 100 lumen/watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified. |
| 64 | Supply & Fixing LED security Light comprising of aluminium die cast body housing, IP 66 with high power LED's as light source suitable for roads,play ground etc of capacity 45 Watts with lance (not less than 100 lumen/watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified. |
| 65 | Supply & Fixing new generation LED post top lantern energy saving, environmental friendly, long life asethetically designed with symetrical light distribution, spun aluminium landscape lumanier with high power LED's as light source of capacity 40 Watts (not less than 100 lumen/watt output) suitable to mount on min 32 mm dia GI tube as post including three core copper cable of size 2.5 sqmm with suitable length all as specified and directed.. |
| 66 | Supply & Fixing new generation LED post top lantern energy saving, environmental friendly, long life asethetically designed with symetrical light distribution, spun aluminium landscape lumanier with high power LED's as light source of capacity 20 Watts (not less than 100 lumen/watt output) suitable to mount on min 32 mm dia GI tube as post including three core copper cable of size 2.5 sqmm with suitable length all as specified and directed.. |
| 67 | S & F INDUSTRIAL LED lights for AVIATION maintanance hangars of capacity 120 W ,The LED make must be of minimum 100 lumen/watt .The driver must be power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection. the luminaire must have secondary optics with perfectly matched lens for better light control with CMRI approved correleted color temperature(CCT) of Emitting light 5700 K with with die cast aluminium housing with heat resistant toughened glass IP 66 protection comlete with control gear box and all accessories require to fix the light on wall/structure/pole like clamps nus, bolts et cwith suitable size and including connecting up with twin core twisted flexible copper conductor cable 1.5x2 sqmm with proper clamps. complete all as specified and directed by Engr in Charge. |
| 68 | Supply and fixing of LED Post top globuster light made up of unbreakable poly carbonate suitable for mounting on post 40 mm dia GI tube, including LED lamp 9 watts including holder all as specified |
| 69 | Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 10 Sqmm 4 core complete all as specified and directed. (Note –necessary excavation and returning filling, sand cushioning and bricks protection shall be measured and paid separately under respective item of BoQ |
| 70 | Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 16 Sqmm 4 core complete specified and directed. (Note –necessary excavation and returning filling, sand cushioning and bricks protection shall be measured and paid separately under respective item of BoQ |
| 71 | Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 10 Sqmm 2 core complete specified and directed. (Note –necessary excavation and returning filling, sand cushioning and bricks protection shall be measured and paid separately under respective item of BoQ Please Enable Macros to View BoQ information |
| 72 | Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 10 Sqmm 2 core complete specified and directed. (Note –necessary excavation and returning filling, sand cushioning and bricks protection shall be measured and paid separately under respective item of BoQ Please Enable Macros to View BoQ information |