| 1 | Cleaning of Clear/Raw water underground (Sump)/OHT/Sludge tank/Back wash tank/jack well/Clarifloculator UG Sump (Clear water UG Sump of Cap 50000 Imperial gallon) manually by trained and skilled manpower of working in under ground sump reservoir with suitable T&P and safety equipments, Tools and safety measures. Draining out the contaminated muddy water from the bottom surface of sump and cleaning the side walls with the help of wire brush including removal green fungus leaves and other dust and dirt ,scraping of dissolved impurities, removal of surface mud /silt ,cleaning with water and draining out complete unwanted material obtained from cleaning as well as apply spray of suitable approved disinfectant chemical safe for human being on inner surface of the sump and apply water proofing coating on inner wall and writing the date of cleaning with synthetic enamel paint on outer surface of tank complete all as specified and directed by Engineer-in-charge.Note :- Sludge/Mud obtained from bottom have to removed and deposited at specified location directed by Engr-in-Chagre. |
| 2 | All as per item no. 1 but for Clear water UG Sump of Cap 100000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 3 | All as per item no. 1 but for Clear water UG Sump of Cap 20000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 4 | All as per item no. 1 but for Over head reservoir of Cap 150000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 5 | All as per item no. 1 but for Over head reservoir of Cap 100000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 6 | All as per item no. 1 but for Over head reservoir of Cap 50000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 7 | All as per item no. 1 but for Raw water jack well of cap 20000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 8 | All as per item no. 1 but for Sludge tank of cap 10000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 9 | All as per item no. 1 but for clarifloculator Semi UG sump of diameter; 14.5 meter and depth exceeding exceeding 7.5 meter complete all as specified and directed by Engineer-in-charge. |
| 10 | All as per item no. 1 but for Over head back wash tank of cap 10000 Imperial gallon complete all as specified and directed by Engineer-in-charge. |
| 11 | All as per item no. 1 but for Alum dosing system / area and filter outlet valve chamber area complete all as specified and directed by Engineer-in-charge. |
| 12 | Supply and fix in replacement of sluice valve iron spindle flanged type of class PN 1.6 complete of size 250 mm dia complete with iron wheel, nuts, bolts and washer incl rubber/fiber flanged joints etc. complete all as specified and directed by Engineer-in-charge. |
| 13 | Supply and fix in replacement of sluice valve iron spindle flanged type of class PN 1.6 complete of size 200 mm dia complete with iron wheel, nuts, bolts and washer incl rubber/fiber flanged joints etc. complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply and fix in replacement of sluice valve iron spindle flanged type of class PN 1.6 complete of size 150 mm dia complete with iron wheel, nuts, bolts and washer incl rubber/fiber flanged joints etc. complete all as specified and directed by Engineer-in-charge. |
| 15 | Supply and fix in replacement of CI non return valve(NRV) of size 100 mm incl nuts and volts, testing etc complete all as specified and directed by Engineer-in-charge. |
| 16 | Supply and fix in replacement of CI non return valve(NRV) of size 150 mm incl nuts and volts, testing etc complete all as specified and directed by Engineer-in-charge. |
| 17 | Supply and fix in replacement of foot valve flanged type of size 200mm bore with necessary gasket , nuts, bolts, and washers etc. including testing for leakage complete all as specified and directed by Engineer-in-charge. |
| 18 | Supply and fix in replacement of foot valve flanged type of size 150mm bore with necessary gasket , nuts, bolts, and washers etc. including testing for leakage complete all as specified and directed by Engineer-in-charge. |
| 19 | M&L disconnecting/dismantling and strip opening of worn out/ defective electric motor of any make and Capacity of 15 HP, 3 phase 415 volts AC supply, taking out burnt stator winding, servicing cleaning of stator slots, bearing, bushes etc rewinding of stator coils with superior quality of copper enamel wire of existing size and specification including insulating material, Varnishing, china glass paper,'F' class paper,Thick sheet paper ( packing sheet) and drying, and replacement of bearings, bushes, rusted nut bolts and washer,seal etc, re-assembling, testing installed and back to original location installation, testing & commissioning on load complete all as specified and directed by Engineer-in-charge. |
| 20 | All as per Srl Item No. 19 here in before , but of capacity 30 HP, 3 phase,440 volts complete all as specified and directed by Engineer-in-charge. |
| 21 | All as per Srl Item No.19 here in before , but of capacity 40 HP, 3 phase,440 volts complete all as specified and directed by Engineer-in-charge. |
| 22 | All as per Srl Item No. 19 here in before , but of capacity 60 HP, 3 phase,440 volts complete all as specified and directed by Engineer-in-charge. |
| 23 | M&L disconnecting/dismantling/liftingup and strip opening of worn out/ defective submersible pump set of any make and Capacity of 7.5/10 HP, 3 phase 415 volts AC supply, taking out burnt stator winding, servicing cleaning of stator slots, bearing, bushes etc rewinding of stator coils with superior quality of copper enamel wire of existing size and specification including insulating material, Varnishing, china glass paper,'F' class paper,Thick sheet paper ( packing sheet) and drying, and replacement of bearings, bushes, rusted nut bolts and washer,seal etc, re-assembling, testing installed and back to original location installation, testing & commissioning on load complete all as specified and directed by Engineer-in-charge. |
| 24 | M&L disconnecting/dismantling/liftingup and strip opening of worn out/ defective submersible pump set of any make and Capacity of 3.0/5.0 HP, 3 phase 415 volts AC supply, taking out burnt stator winding, servicing cleaning of stator slots, bearing, bushes etc rewinding of stator coils with superior quality of copper enamel wire of existing size and specification including insulating material, Varnishing, china glass paper,'F' class paper,Thick sheet paper ( packing sheet) and drying, and replacement of bearings, bushes, rusted nut bolts and washer,seal etc, re-assembling, testing installed and back to original location installation, testing & commissioning on load complete all as specified and directed by Engineer-in-charge. |
| 25 | M & L disconnecting electric connections,dismantling,taking up centrifugal pumping set capacity 60 HP from existing foundation,transporation to workshop for repair and back to installation after repairing and welding,brazing,facing grinding, turning repairing/replacement of defective parts such as oil seal/gland plate, coupling etc. ,re-assemblying and fixing to its original position and testing pumping set complete all as specified and directed by Engineer-in-charge.Note :- SS impeller, brass bushes, stainless steel shaft & ball bearing shall be measured & paid separately as supply only. |
| 26 | Supply only SS Impeller as per existing size and make 60HP complete all as specified and directed by Engineer-in-charge. |
| 27 | Supply only Brass bushs as per existing size and make 60HP complete all as specified and directed by Engineer-in-charge. |
| 28 | Supply only Stainless steel shaft as per existing size and make 60HP complete all as specified and directed by Engineer-in-charge. |
| 29 | Supply only Ball bearing as per existing size and make 60HP complete all as specified and directed by Engineer-in-charge. |
| 30 | M & L disconnecting electric connections,dismantling,taking up centrifugal pumping set capacity 30/40 HP from existing foundation,transporation to workshop for repair, and back to installation after repairing and welding,brazing,facing grinding, turning repairing/replacement of defective parts such as oil seal/gland plate, coupling etc. ,re-assemblying andfixing to its original position and testing pumping set complete all as specified and directed by Engineer-in-charge.in-charge.Note :- SS impeller, brass bushes, stainless steel shaft & ball bearing shall be measured & paid separately as supply only. |
| 31 | Supply only SS Impeller as per existing size and make 30/40 HP complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply only Brass bushs as per existing size and make 30/40 HP complete all as specified and directed by Engineer-in-charge. |
| 33 | Supply only Stainless steel shaft as per existing size and make 30/40 HP complete all as specified and directed by Engineer-in-charge. |
| 34 | Supply only Ball bearing as per existing size and make 30/40 HP complete all as specified and directed by Engineer-in-charge. |
| 35 | M & L disconnecting electric connections,dismantling,taking up centrifugal pumping set capacity 15 /20 HP from existing foundation,transporation to workshop for repair, and back to installation after repairing and welding,brazing,facing grinding, turning repairing/replacement of defective parts such as oil seal/gland plate, coupling etc. ,re-assemblying andfixing to its original position and testing pumping set complete all as specified and directed by Engineer-in-charge.Note :- SS impeller, brass bushes, stainless steel shaft, ball bearing & gland plate shall be measured & paid separately as supply only. |
| 36 | Supply only SS Impeller as per existing size and make 15/20 HP complete all as specified and directed by Engineer-in-charge. |
| 37 | Supply only Brass bushs as per existing size and make 15/20 HP complete all as specified and directed by Engineer-in-charge. |
| 38 | Supply only Stainless steel shaft as per existing size and make 15/20 HP complete all as specified and directed by Engineer-in-charge. |
| 39 | Supply only Ball bearing as per existing size and make 15/20 HP complete all as specified and directed by Engineer-in-charge. |
| 40 | Supply only Gland Plate as per existing size and make 15/20 HP complete all as specified and directed by Engineer-in-charge. |
| 41 | Material and Labour charges for collection of Sample for Chemical examination & Bacteriological examinationof Raw water from raw water pond and clear water from clear water installation and send to authorized lab for testing and report will be submitted in triplicate to deptt including cost of testing complete all as specified and directed by Engr-in-charge.Note :- Collection of sample in Sterilized Glass Bottle up to the neck and sealed properly. |
| 42 | M & L for dismantling of sluice valve of any size for refacing, regrinding and replacement of check nut, rubber gasket, making the threads of spindle and after repair of sluice valve and re-fixing its original position complete all as specified and directed by Engineer-in-charge. |
| 43 | M& L for repairs and servicing of flaculators assembly with gear reduction system, oil change, greasing of rotating parts and fixed arms and repair and replacement of central thust bearing , rear box bearing, slip ring assembly , fan belt, chain of gear reduction assembly of flaculator complete all as specified and directed by Engineer-in-charge. |
| 44 | M & L repairs to water supply pipe line for removing leakage / blockage of GI pipe line 15mm to 40 mm bore including providing gasket /socket/tee/elbow/bend/union/nipple, washers, nuts,bolts, making thredes etc. by carryout necessary excavation in any type of soil, return filling, removing, dewatering as required earth work as required complete all as specified and directed by Engr-in-charge.Note :- Earth work and GI pipe will be measured and paid seperatly. |
| 45 | M & L repairs to water supply pipe line for removing leakage / blockage of GI pipe line 50 mm to 80 mm bore including providing gasket /socket/tee/elbow/bend/union/nipple, washers, nuts,bolts making thredes etc. by carryout necessary excavation in any type of soil, return filling, removing, dewatering as required earth work as required complete all as specified and directed by Engr-in-charge.Note :- Earth work and GI pipe will be measured and paid seperatly. |
| 46 | M&L for taking out old rusted GI pipe of size 15 mm to 50 mm complete all as specified and directed by Engineer-in-charge. |
| 47 | S & F 20 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 48 | S & F 25 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 49 | S & F 40 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 50 | S & F 50 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 51 | S & F 80 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 52 | S & F in replacement of gun metal, globe or gate valve with iron wheel head secrewed both ends for iron pipes 50 mm bore as in repairs complete all as specified and directed by Engineer-in-charge. |
| 53 | S & F in replacement of gun metal, globe, Ball or gate valve with iron wheel head secrewed both ends for iron pipes 40 mm bore as in repairs complete all as specified and directed by Engineer-in-charge. |
| 54 | S & F in replacement of gun metal, globe, ball or gate valve with iron wheel head secrewed both ends for iron pipes 25 mm bore as in repairs complete all as specified and directed by Engineer-in-charge. |
| 55 | S & F in replacement of gun metal, globe, ball or gate valve with iron wheel head secrewed both ends for iron pipes 20 mm bore as in repairs complete all as specified and directed by Engineer-in-charge. |
| 56 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundations or laying cables/pipes etc. and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge. |
| 57 | Returning, filling in including spreading leveling, watering and well ramming in layers of Soft/loose soil not exceeding 25 cm thick complete all as specified and directed by Engineer-in-charge. |
| 58 | Removal of excavated material to a distance not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. |
| 59 | Supply and fix in repair, star delta startor for non clog motor 10 HP 3 Phase 415 Volts complete all as specified and directed by Engineer-in-charge. |
| 60 | Supply and fix in repair, star delta startor for non clog motor 15 HP 3 Phase 415 Volts complete all as specified and directed by Engineer-in-charge. |
| 61 | Supply and fix in repair, star delta startor for non clog motor 20 HP 3 Phase 415 Volts complete all as specified and directed by Engineer-in-charge. |
| 62 | Supply and fix in repair DOL Starter for motor 7.5 HP, 3 Phase 415 Volts complete all as specified and directed by Engineer-in-charge. |
| 63 | M&L for painting the surface of CI/GI pipe of size up to 300 mm with valve, as per requirement places complete with one coats of primer and two coat of enamel paint as per MES colour code including preparation of surface by scrubbing down old existing paint complete all as specified and directed by Engineer-in-charge. |
| 64 | Material and labour for servicing of Air Blower installed at Filteration plant with replacement of cooling oil, bearing set, oil seal set, relief valves, Air filter, V-Belts etc. complete all as specified and directed by Engineer-in-charge. |
| 65 | M&L for painting the surface of each pump -motor set of any cap. as per requirement places complete with one coats of primer and two coat of enamel paint as per MES colour code including preparation of surface by scrubbing down old existing paint complete all as specified and directed by Engineer-in-charge. |
| 66 | M&L for Dewatering the stagnated polluted water and desilting of Raw Water tank manually including bailing out mud/sludge by pumps/ manually without damaging bottom lining of tank from 100 lakh gallons capacity raw water tank of size 140 m x 140 m x 4.5 mtr( Note depth not more than 4.5 meter) by pumping out using diesel engine operating pumping set or electricity operated pumping set and draining out the polluted water liquid mud water to distance not exc 100 mtr away from the edge of the tank complete all as specified and directed by Engr-in-charge. Note:- Dewatering shall be carried out by pumping system using diesel operated engine pumping set . In case the pumping is done by using electrically operated pumping set then electricity shall be supplied by the MES and shall be charged at rates indicated in particular specification . |
| 67 | Supply & install, commissioning, testing of out-door type feeder pillar, LT type (CPRI approved) of size 1.25 mtr Width x 1.5 Height mtr x 0.4 Depth mtr fabricated out of 3.15 mm thick CRCA sheet angle size 50 x 50 x 5 mm thick frame factory made totally enclosed dust and vermin proof are side hinged opening arrangement on front and back with weather proof canopy of top with locking arrangement, cable entry and exist from bottom both side.a) MCCB 100 A,415 Volts 4 pole, 16 KA-(Adj Thermal Mag sett)-01 nos (Incoming)b) Indicator lamp LED type (set of three Red,Yellow,Blue)-01 setc) MPCB 63 A,415 Volts 3 pole-01 nosd) MPCB 32 A,415 Volts 3 pole-01 nose) MPCB 20 A,415 Volts 3 pole-02 nosf) Star Delta Starter for 40 HP Motor-01 nosg) VFD Device based starter for 7.5 HP Motor-02 nosh) VFD Device based starter for 5.0 HP Motor-01 nosi) Aluminum bus bar 150 Amp , Reqd length -04 nosj) Digital Volt meter & Ammeter with suitable CT's each (500+400)-01 set |
| 68 | Supply & install, commissioning, testing of out-door type feeder pillar, LT type (CPRI approved) of size 1.25 mtr Width x 1.5 Height mtr x 0.4 Depth mtr fabricated out of 3.15 mm thick CRCA sheet angle size 50 x 50 x 5 mm thick frame factory made totally enclosed dust and vermin proof are side hinged opening arrangement on front and back with weather proof canopy of top with locking arrangement, cable entry and exist from bottom both side.a) MCCB 63 A,415 Volts 4 pole, 16 KA-(Adj Thermal Mag sett)-01 nos (Incoming)b) Indicator lamp LED type (set of three Red,Yellow,Blue)-01 setc) MPCB 32 A,415 Volts 3 pole-02 nosd) MPCB 20 A,415 Volts 3 pole-02 nose) VFD Device based Starter for 15 HP Motor-02 nosf) VFD Device based Starter for 7.5 HP Motor-01 nosg) VFD Device based Starter for 5.0 HP Motor-01 nosh) Aluminum bus bar 100 Amp , Reqd length -04 nosi) Digital Volt meter & Ammeter with suitable CT's each (500+400)-01 set |
| 69 | Supply & install, commissioning, testing of out-door type feeder pillar, LT type (CPRI approved) of size 1.25 mtr Width x 1.5 Height mtr x 0.4 Depth mtr fabricated out of 3.15 mm thick CRCA sheet angle size 50 x 50 x 5 mm thick frame factory made totally enclosed dust and vermin proof are side hinged opening arrangement on front and back with weather proof canopy of top with locking arrangement, cable entry and exist from bottom both side.a) MCCB 100 A,415 Volts 4 pole, 16 KA-(Adj Thermal Mag sett)-01 nos (Incoming)b) Indicator lamp LED type (set of three Red,Yellow,Blue)-01 setc) MPCB 63 A,415 Volts 3 pole-04 nosd)VFD Device based Starter 40 HP Motor-04 nose) Aluminum bus bar 150 Amp , Reqd length -04 nosf) Digital Volt meter & Ammeter with suitable CT's each (500+400)-01 set |
| 70 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth of not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanized iron earth strip 25x4 mm thick fixed by means of bolts, nuts and washers and watering pipe 20mm die GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire mean etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and directed by Engr-in-charge Notes :- (i) 25 mm die GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI pipe 40 mm die protection pipe shall be provided upto Ground level. Please Enable Macros to View BoQ information |
| 71 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth of not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanized iron earth strip 25x4 mm thick fixed by means of bolts, nuts and washers and watering pipe 20mm die GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire mean etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and directed by Engr-in-charge Notes :- (i) 25 mm die GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI pipe 40 mm die protection pipe shall be provided upto Ground level. Please Enable Macros to View BoQ information |