| 1 | M&L for painting on steel pole initially scraping deteorated paint by emery paper and complete removal of rusted suface, painted with one coat of red oxide zinc chrome primer on exposed prepared surface and providing 03 Nos of 30 cm wide circular bands with black and yellow paint starting from bottom level at a gap of 30 cm in between 2 bands and numbering of pole with yellow paint over black painted background at the height og 02 meter from the bottom of pole with 02 cm larger Bold letter of height 2 inch complete all as specified |
| 2 | S&F 20 mm dia Unplasticised PVC pipes of pressure rating 10 Kgf/cm2 fixed on pole with suitable size of clamps made out of MS flat with the size of pole , nut, bolt etc complete all as specified |
| 3 | S & F PVC insulated stranted copper conductor cable of size 2.5 sqmm x 3 core from Juction box to street light complete all as specified |
| 4 | S&F in replacement of 2 Pole 18 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified |
| 5 | S&F in repair 3 Pole 40 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified |
| 6 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant with driver and lamp complete all as specified |
| 7 | Boring of holes under road, pavement, hard standing for laying of pipe upto 100 mm bore complete all as specified. Note :- GI pipe shall be measured and paid in concern Item |
| 8 | S & F or laying galvanised steel tubing Light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of following size complete all as specified. |
| 9 | 40 mm bore. |
| 10 | 50 mm bore. |
| 11 | 80 mm bore. |
| 12 | Supply and fixing of Lithium base Energy efficient integrated Solar street light of 30 watt in Aluminium Die casting body ,corrosion resistance,built in high efficiency solar panel and long life lithium ferro phosphate battery with high efficiency microprocessor based charge controlar Automatic dusk to input voltage 12.8 V with minimum 30 AH battery capacity ,Driver efficiency .85%,PV module minimum output capacity 60 W/h Mono itself will be used to sense the ambient light to switch ON/OFF the Lamp from outside from Light fittings and controled from Pole controlling switch,inbuilt MPPT charge controller,IP65,both PIR and fixed dimming available,4500 lumens (at full brightness) with grater than 150 lumen per watt,5700ANSI,,CRI.70,moptical used, Metal core PCB,Low voltage cutoff ,high power LED,wide beam Angle(135/85 degree) with PIR Sensor LED Life 50000 hrs (LM80 cerified LED),weight less than 15 kg with Green/Red indicator with with battery rating 12.8V-BIS standard along with 5 year warranty coveredcomplete all as specified. Make : Orient / Tata PowerShakti fixtures / Phillips |
| 13 | Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide complete all as specified.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 14 | M&L for cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foudation,fillingand mass concrete complete all as specified. |
| 15 | M&L for cement concrete 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in foudation,filling and mass concrete complete all as specified |
| 16 | M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement complete all as specified |
| 17 | M&L for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 20 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm complete all as specified ( Note:- Up to 7.5 Mtr length of pipe of 20 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI wire ) |
| 18 | Supply and fix in replacement of IP65 rated LED Bollard Mushroom type with soft 360 deg light distribution with base plate and necessary foundation and connected electric connections and PCC work complete all as specified |
| 19 | Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified |
| 20 | Excavation in trenches not exc 1.5 M wide and exc 1.5 M in depth but not exc 3.0 M depth for pole foundation, in soft / loose soil getting out and levelling of bottom surface to required level complete all as specified |
| 21 | Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified |
| 22 | Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified |
| 23 | M&L Protection to cable with one layer of bricks laid flat abutting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks, complete all as specified. |
| 24 | M&L Un washed dry river sand as cushioning of under ground cable and punned after laying complete all as specified. Note: Only punned thickness will be measured Please Enable Macros to View BoQ information |
| 25 | M&L Un washed dry river sand as cushioning of under ground cable and punned after laying complete all as specified. Note: Only punned thickness will be measured Please Enable Macros to View BoQ information |