| 1 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 2 | Supply and fix electric water heater, storage type steel body with SS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. |
| 3 | M&L of point wiring with PVC insulated unsheathed FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire,and including PVC conduit heavy duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board and screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete all as specified and directed. |
| 4 | M&L of point wiring with PVC insulated unsheathed FRLS copper conductor cable of size 2.5 Sqmm, with PVC insulated unsheathed FRLS copper conductor cable of size 2.5 Sqmm for earth continuity wire,and including PVC conduit heavy duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board and screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete all as specified and directed. |
| 5 | M&L for Cutting and drilling of wall for fixing of Exhaust fan and making good disturbed surfaces of walls,are included same price complete all as specified and directed. |
| 6 | Supply and Fixing of Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 7 | S&F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 8 | S&F Modular White Cover Plate with Frame, 4 Module complete all as specified and directed. |
| 9 | S&F Modular Metal Flush Box 4 module complete all as specified and directed. |
| 10 | S&F Modular Metal Flush Box 3 module complete all as specified and directed. |
| 11 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 12 | S&F Modular socket 16A, complete all as specified and directed. |
| 13 | S&F Modular White Cover Plate with Frame, 3 Module complete all as specified and directed. |
| 14 | Supply and fixing of Louvers with GI wire mesh( 24 SWG) for Existing Exhaust fans Louvers are made of MS, flops type, Thick 2mm inculding suitable rust proof nuts and bolts, fixing on up to 9 story buildings heights and applying 2 coat brown colour synthetic enemal paints complete all as specified and directed. |
| 15 | Supply and Fixing of Wiring for circuit/submain wiring alongwith earth wire with the 2.5 Sqmm sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required wall cutting and making good disturbed surface complete all as specified and directed. |
| 16 | Supply and Fixing of Commercial Kitchen Hoods Wall Mounting made by Jindal Steel with 202 Grade & 22 Gaze. 02 Nos of SS Wall Mounting Hoods size (36X30X18)’’.75 Rft SS Ducting thickness 22 Gaze of wall Ducting size(12\\"x18\\"). 2nos of 18’’ Exhaust Fan Heavy duty single phase 1400 RPM, Copper Winding Motor. For Coock House complete all as specified and directed. |
| 17 | M&L for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including stove enamelled Steel Conduit with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete all as specified and directed. |
| 18 | M&L for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2.5 Sqmm for earth continuity wire, to be drawn in and including stove enamelled Steel Conduit with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete all as specified and directed. |
| 19 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 20 | Supply and fixing Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 21 | Supply and fixing of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed. |
| 22 | Supply and fixing of Flame proof industrial type Electric exhaust blower wall mounted type 350 mm sweep, Staineless steel body casing and cast alloy aluminium impeller duly statically and dynamically balance for single phase AC 230 V, 50 Hz electric motor, for gas and smoke exhaust application ,min air flow 5000 CFM, including all necessary wall Drilling and making good disturbed surface complete all as specified and directed.Note :- wall Drilling and making good disturbed surface is not measured separately. |
| 23 | Supply and Fixing of Wiring for circuit/submain wiring alongwith earth wire with the 2.5 Sqmm sizes of FRLS is PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed. |
| 24 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 A current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 25 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 10 A current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 26 | Supply and Fixing Of MCB DB (Sheet metal encloser Double Door 240 V 4 way with 200 amps rated copper bus bar complete all as specified and directed. |
| 27 | Taking down of copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 28 | Taking down of old fans,ceilling rose and related accessares complete all as specified and directed. |
| 29 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote complete all as specified and directed. |
| 30 | Supply and fixing in Replacement of Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 31 | Supply and fixing in Replacement of Ceiling rose, 3 phase/PVC/polycarbonate, isolated bodyModular switch 1 way 6A,1 module complete all as specified and directed. Please Enable Macros to View BoQ information |