| 1 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, THD < 10% as per IEC 61000-3-2, P.F. ≥ 0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg - 120 deg as per the application and the project requirement, suitable tiltable fitting, lifetime (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not be more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 to <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape, size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 2 | 150 watt |
| 3 | Supplying and fixing of SMC Junction box having size 140 x 140 x 95 mm Single door, pole mounted weatherproof SMC junction box compete with terminal block suitable for 25 sq. mm conductor, DIN bar, SP MCB with suitable. M.S. clamp on the existing pole for light fixture etc as required |
| 4 | Supplying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1 KV grade of following size on wall surface as required. |
| 5 | 3X10 Sq.mm |
| 6 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 7 | 4X25 Sq. mm. |
| 8 | Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 9 | 4X25 Sq. mm. |
| 10 | laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 11 | 3.5X50 Sq.mm |
| 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 13 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 15 | 4 X 25 sq. mm (28mm) |
| 16 | Supplying and fixing of 63 Amp. terminal block with laminated sheet of suitable size for 25 Sq.mm conductor 4 nos. On DIN Channel i/c providing & fixing of DIN Channel of suitable length for single pole MCB etc. Complete as required. |
| 17 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 18 | Group C |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 20 | 6 way , Double door |
| 21 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Single pole |
| 23 | Double pole |
| 24 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 25 | 18- 22 Watt |
| 26 | Supplying, installation, testing and commissioning of 1200 mm sweep ceiling fan having copper wound motor and suitable for operation on 230 volt 50 Hz AC Supply including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable complete etc. as required. |
| 27 | Supplying & Intallation of heavy duty exhaust fan 380 mm sweep 1400 rpm, having 4 blades with shutter and louver in the existing opeining , including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 28 | Supplying and fixing 400mm sweep, 1300 RPM wall mounted cabin fan with 3 blade, speed regulator oscillating type i/c testing & Commissioning etc. as reqd. |
| 29 | Supplying, Installation, Testing and commissioning of Industrial Heavy Duty hunderstorm Pro Air Circulator wall fan 3 blade, 600 mm sweep, single phase, 230 V, 1400 RPM i/c testing and commissining etc. completed as required. |
| 30 | SITC of floor mounted Water Dispenser body made of ABS plastic and tank made of food grade stainless steel with hot, normal and cold type i/c inbuilt mini refrigerator water dispensing. Heating capacity 2 Ltrs/Hr & cooling capacity 5.00 ltr/hr, Refrigerant :- Non CFC (R134a) with 3 tabs, Single phase, 230 V, 50 Hz, i/c testing and commissiong etc. complete as reqd. |
| 31 | Providing and replacement of following worn out panel accessories in the existing panel including replacement of worn/burnt out control wiring of contactors, relay, timer with new suitable copper wire, thimbles etc complete testing on load by transfer from star to delta and replacement of following accesories etc complete as reqd. (a) 4 pole MCCB, 200A, 36KA-01 Nos. (b) 4 pole MCCB, 100A, 30KA -04 Nos. (c) ML-6 Heavy Duty 3 pole Contactor with 2NO+2NC Aux contact with suitable size Aluminium cable : 1 No. (d) Electronic Timer 03 sec to 30 sec Star/Delta- 1 C/O + 1 C/O: 1 No. (e) LED Indicating Light RYB 240 Volts: 3 Nos. (f) 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" Single Pole MCB.: 3 Nos. (g) 0-500 V Digital Volt Meter : 1No. (h) 0-400 A Digital Ampere Meter : 1No. (i) Push Button ON/OFF alongwith NO/NC |
| 32 | Cutting road and making good the same including supply of extra quantities of mateiral i.e aggregate, moorum screening, red bajri and labour required. (a) bituminous portion |
| 33 | Supplying & fabrication of wire mesh protection frame work fabricating with 40mm x 40mm x 6 mm thick angle iron and tee iron of 40mm x 40mm x 6mm thick by making blocks of not less than 90cm x 90cm in frame i/c providing and fixing wiremesh of section 75mm x 25mm of i/c openable door from front side of the same formation with locking arrangement having weight not less than 7.75kg/sq.mtrs and shall be fixed with the help of nut bolts and all frame work is to be painted with two or more coats of synthetic enamel paint complete etc. as required. |
| 34 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within50 metres lead as per direction of Engineer-in-charge :bituminous road |
| 35 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 36 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. Please Enable Macros to View BoQ information |