Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | EQUIPMENT |
| 2 | Modular X Ray Viewer |
| 3 | Modular Surgeon Control Panel |
| 4 | Modular Medical Gas Pipeline System |
| 5 | Modular Anesthesia Pendant |
| 6 | Modular AGSS Connection with Balancer and Receiver |
| 7 | High End C-ARM |
| 8 | AI Enable Patient Monitor |
| 9 | Modular High End Operating Room Light |
| 10 | C-Arm Combatable OT Table with Bolsters |
| 11 | High End Portable Ultrasound |
| 12 | Civil Work |
| 13 | DISMANTLING AND DEMOLISHING |
| 14 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 15 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 16 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 17 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 18 | GLASS PANEL WALL |
| 19 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 20 | Providing and fixing modular glass panel wall system comprising 10 mm thick toughened safety glass panels conforming to EN 1863-1 and EN 12150-1, installed on a non-load bearing GI sub-frame (minimum 2 mm thick) with necessary supports, including factory-fabricated panels with smooth finish, mechanical fixing system (no welding), joints sealed with removable medical-grade silicone gasket (no liquid silicone), provision for flush mounting of equipment and service integration within cavity, and all accessories, fittings, alignment, and installation, complete as per approved design and directions of Engineer-in-Charge. Frame to be paid seperately. |
| 21 | WALL CLADDING |
| 22 | Providing and fixing anti-bacterial solid mineral surface wall cladding system comprising alpha-cellulose fibre panels impregnated with thermosetting synthetic resins, fixed on a standalone GI framework or with clamps, having high resistance to abrasion, scratches, heat, chemicals, moisture, and bacterial growth, with joints sealed using silicone/gasket/SS strips, including SS 304 grade L-angles at corners, corner guards at pillars, and SS 304/GI skirting at floor level, complete with all fittings, accessories, alignment, and installation as per approved design and direction of Engineer-in-Charge. Frame to be paid seperately. |
| 23 | MODULAR CEILING PANEL |
| 24 | Providing and fixing modular ceiling panel system comprising factory-prefabricated, detachable clip-in panels with locking arrangement and sealed joints, suspended on a galvanised steel framework of 0.6–0.8 mm thickness, with adjustable suspension height from 110 mm to 250 mm (+25 mm tolerance) using tension springs, finished with antibacterial and antimycotic coated surface for long-term microbial protection, including all supports, fittings, sealing, alignment, and installation, complete as per approved design and direction of Engineer-in-Charge. |
| 25 | FALSE CEILING |
| 26 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board |
| 27 | FLOORING |
| 28 | Providing and laying 2 mm thick homogeneous conductive flooring with carbon backing, polyurethane reinforced, having properties of scratch resistance, fire resistance, chemical resistance, slip resistance, and resistance to fungal and bacterial growth, laid over 3 mm thick self-levelling compound substrate, including coving at wall-floor junctions, and earthing through copper strips, complete with all materials, adhesives, preparation, finishing, and installation, as per approved design and direction of Engineer-in-Charge. |
| 29 | Providing and laying imported 2 mm thick homogeneous medical-grade vinyl flooring having anti-bacterial, anti-fungal, and anti-skid properties, laid over a prepared substrate with flatness tolerance of ±3 mm over 1 sqm, including application of primer and 2–3 mm thick self-levelling compound, with coving at wall-floor junctions, complete with all adhesives, materials, finishing, and installation, as per approved design and direction of Engineer-in-Charge, in console room, store room, corridors, and other peripheral areas. |
| 30 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 31 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 32 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm |
| 33 | DOORS |
| 34 | Providing and fixing hermetically sealing horizontal sliding door of size 1800 × 2100 mm, comprising 2 mm thick lead lining, with 60 mm thick door panel made of CFC-free rigid polyurethane core sandwiched between 4 mm HPL laminates on both sides, framed in extruded aluminium alloy profiles (Grade 6063 T6) with natural anodized finish (20 µm), including EPDM removable sealing gaskets on vertical and top profiles and hermetic bottom sealing gasket, capable of withstanding up to 75 Pa overpressure without measurable leakage, complete with 300 × 300 mm flush vision panel (tempered glass IG unit) and automatic operation with microprocessor-based controller (SDA-04 or equivalent), touchless sensors, and photo-cell safety system, including all fittings, accessories, installation, testing, and commissioning, as per approved design and direction of Engineer-in-Charge. |
| 35 | Providing and fixing PPGI sheet puff panel clean room door of size 900 × 2100 mm (as per site), comprising 30–50 mm thick insulated panel with PPGI sheets on both sides and rigid core, complete with integral door frame, including 300 × 300 mm view panel with glass, and all necessary hardware such as hinges, door lock, door closer, door seals, and interlocking arrangement for passive leaf, complete with all fittings, accessories, alignment, and installation, as per approved design and direction of Engineer-in-Charge. |
| 36 | Providing and fixing modular cabinets using High Pressure Laminate (HPL) compact laminate boards of approved shade and thickness, including necessary framework, shutters, shelves, hardware, edge finishing, SS fittings, hinges, handles, locks, and all accessories, complete as per approved design and direction of Engineer-in-Charge. |
| 37 | Providing and supplying high-end laptop computers suitable for engineering, design, planning, and office applications, with latest generation multi-core processor, minimum 16 GB RAM, dedicated graphics card, minimum 512 GB SSD storage, full HD display, wireless connectivity, webcam, keyboard, preloaded licensed operating system and office software, complete with charger, accessories, warranty, installation, and commissioning, as per approved specifications and direction of Engineer-in-Charge. |
| 38 | PARTITION WALL FOR CABIN |
| 39 | Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top and bottom pivots, fixing arrangements, and making necessary holes for installation, complete in all respects, as per the direction of the Engineer-in-Charge. |
| 40 | Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top and bottom pivots, fixing arrangements, and making necessary holes for installation, complete in all respects, as per the direction of the Engineer-in-Charge. |
| 41 | Supply of SS corner lock for toughened glass door of 12mm thick with weight upto 200kg |
| 42 | Supply of stainless steel handle for toughened glass door, H- type of size 450 mm and 25 mm dia with satin finish of reputed make . |
| 43 | FURNITURE |
| 44 | Providing and fixing Multiwood table unit of size 1.5 m length × 0.5 m width × 0.75 m height, made of approved quality high-density Multiwood board with laminated finish, including smooth finished edges, suitable supporting framework, and storage cupboards with shutters below at both ends, complete with all necessary hardware, hinges, handles, locks, screws and fittings as directed by the Engineer-in-Charge. |
| 45 | Providing and supplying Executive Chair with high back ergonomic design, cushioned seat and backrest upholstered in approved fabric, adjustable height mechanism with tilt function, adjustable armrests, heavy duty base with smooth castor wheels, chrome finished frame and all accessories complete as approved. |
| 46 | Providing and fixing white board of size 1800 mm × 1200 mm, comprising smooth writing surface with aluminium frame, marker tray and necessary wall fixing arrangements complete as approved. |
| 47 | Providing and supplying patient step made of heavy duty mild steel frame with anti-skid rubber, powder coated finish, non-slip rubber shoes at bottom and all necessary fittings complete as approved. |
| 48 | Providing and supplying steel stool made of heavy duty mild steel tubular frame with chrome finish, plain seat top as approved, fitted with non-slip rubber shoes and all necessary fittings complete. |
| 49 | Providing and supplying 2-seater sofa of size approximately 1.4 m length, made with seasoned wooden framework, cushioned seat and backrest upholstered in approved fabric, complete with armrests, legs, base support and all necessary fittings and accessories, finished and fixed complete as approved by the Engineer-in-Charge. |
| 50 | Providing and fixing L-shaped Multiwood table unit of size 1.6 m × 0.5 m × 0.75 m, fabricated from approved quality high-density Multiwood board with laminated finish to top and exposed surfaces, including suitable supporting framework, drawers and storage cabinets, complete with shutters, handles, locks, hinges, fittings and all necessary accessories, finished and fixed in position as directed by the Engineer-in-Charge. |
| 51 | Providing and fixing open-type cupboard of size 3.0 m length × 0.6 m width × 1.8 m height, made of approved quality Multiwood board of required thickness with laminated finish on exposed surfaces, comprising open shelves and storage compartments of approved configuration, complete with necessary framework, edge banding, supports, hardware fittings and all required accessories, finished and fixed in position as approved by the Engineer-in-Charge. |
| 52 | Providing and fixing lockable steel cupboard unit of size 0.9 m length × 0.5 m width × 1.8 m height, fabricated from heavy-duty CRCA steel sheet of required thickness with powder-coated finish, comprising upper glazed double shutters with clear glass panels and lower closed double shutters with locking arrangement, including internal adjustable shelves, handles, locks, hinges, base supports and all necessary hardware fittings and accessories, finished and fixed in position complete as approved by the Engineer-in-Charge. |
| 53 | Providing and fixing overhead storage loft unit of size 1.5 m length × 0.45 m width × 1.0 m height, made of approved quality Multiwood board of required thickness with laminated finish on exposed surfaces, comprising enclosed storage with shutters and internal shelves as approved, complete with necessary supporting framework, edge banding, handles, hinges, locks, hardware fittings and all required accessories, finished and fixed in position complete as directed by the Engineer-in-Charge. |
| 54 | SIGNAGES |
| 55 | Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 16\\" x 10\\". Complete as per the per the direction of Engineer in charge. |
| 56 | Electrical Works |
| 57 | Point wiring in PVC conduit with modular type switch. |
| 58 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group B |
| 59 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 60 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 61 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 62 | Wiring through PVC conduit |
| 63 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 64 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 65 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 66 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 67 | S/F PVC CONDUIT |
| 68 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 69 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 70 | Modular type blanking plate: |
| 71 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 72 | Modular boxes, bases & cover plate: |
| 73 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 74 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 75 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 76 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface |
| 77 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 78 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 6 module moulded plastic box on surface |
| 79 | Modular type switch/socket: |
| 80 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 81 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 82 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 83 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 84 | DB ACCESSORIES |
| 85 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 86 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 18), Double door |
| 87 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 88 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A-40A, 4P, 100mA |
| 89 | Supplying and fixing 40A / 63A, TP MCB, 415 Volts, \\"C\\" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 90 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 91 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 92 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 93 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 16 KA,TPMCCB |
| 94 | Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/ RCCB /RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 95 | EARTHING |
| 96 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 97 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 98 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 99 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 10 SWG) |
| 100 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 101 | SUPPLY OF LT CABLES |
| 102 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5X 70 |
| 103 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 16 |
| 104 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4X10 |
| 105 | CABLE LAYING |
| 106 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 107 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 108 | LT CABLE TERMINATION |
| 109 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) |
| 110 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm) |
| 111 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm) |
| 112 | CABLE TRAYS |
| 113 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 114 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 115 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 116 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 117 | LIGHT FITTINGS & FANS |
| 118 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not riseabove 90°C).Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 36 watt |
| 119 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Wattoutput . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housing such that LED junctiontemperature shall not rise above 90°C) Powder coated die cast /Extruded aluminiumBody including trim Powder coated die cast /Extruded aluminiumBody including trim .18 watt |
| 120 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt |
| 121 | SITC of recessed 32W LED peripheral lighting of size 600 x 600 mm with optical antiglare system for adjustable light distribution and suitable for clean room application, Luminaries cover should be made of highly resistant, disinfectant proof laminated safety glass/acrylic with stylish fine-grained surface. Fittings should be sealed In accordance with the standard IP54 |
| 122 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 123 | UPS AND ISOLATION PANEL |
| 124 | Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding theload / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 10KVA (Each Power module shall be < 10 KVA) Each 208893 |
| 125 | Supply of Medical IT System for Group-2 location: Incomer : 63A DP MCB 10kVA with On / Off Indicator - With 16Sqmm Terminals.Medical isolationTransformer : 10 kVA Rating Medical Isolation Transformer with Copper Windings. The leakage current from the output winding to earth and the enclosure, measured at no-load condition with rated voltage and frequency, must not exceed 0.5 mA as per IEC61558-2-15 - 1 Nos, Primary Side : Single Phase 230v, Secondary Side : 230v.Monitoring Devices : 1. Medical Insulation Monitoring Device (MED-IMD) Tested as per IEC 61557-8 with storage of up to 100 Incident Logs, RS 485 for Communication, Overload and Temprature for Transformer Measurement and Indication as per the set values. The injected current, even under fault conditions, must not exceed 1 mA peak. The a.c. internal impedance must be at least 100 kΩ. An alert must be triggered when insulation resistance drops to 50 kΩ. The test voltage should not exceed 25 V d.c. 2. Fault Locator (MED-IFLS) for each outgoing channels as per IEC 61557-9 to locate and identify the circuit (6 channels) - 4 Nos. 3. PE conductor monitoring system(PECM) to identify the PE conductor status (6 channels) - 4 Nos.The panel should provide visual alerts via LED indicators and sound alerts for issues such as insulation level faults, overloads, temperature alarms, and protective earth continuity problems, with a green lamp for normal operation and a yellow lamp that lights up when the minimum insulation resistance value is reached. An audible alarm also must sound when the minimum insulation resistance value is reached. This alarm may be silenced manually, but the yellow signal lamp must remain lit until the fault is corrected. The system panel must display key information, including insulation levels, load, and temperature values in the display unit.Outgoing : 24 x 16A DP C Curve MCB 4 Sqmm Terminals - 96 Nos Panel enclosure is constructed from 14SWG thick galvanized sheet steel providing a durable and rigid framework. Panel shall be Powder-coated in RAL7032 texture for protection against environmental factors. Doors are made of 14SWG CRCA sheet steel hinged with a 120-degree opening and reversible installation (left or right). A 3-point locking mechanism enhances security and ease of use, and the design shall include removable top and side covers with double-bent edges for extra strength |
| 126 | NETWORK |
| 127 | Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 128 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable |
| 129 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 130 | Supplying Installation Testing and Commissioning of 2MP IP IR Dome Camera having followingspecifications, type of lens and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB, Camera should display Camera title, Date &Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive ScanCMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better,H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable (Main stream: 2MP (1920×1080)@25/30 fps,Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client softwareor web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, syslog, videoencryption, IP/MAC filtering, HTTPS, trusted upgrade,trusted boot.9) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.280 10) Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast13) System Capability: ONVIF, Camera shall supportopen source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1Alarm In/ Out for External Mic. and Speakers as persite requirement.16) Power Input: The camera should supportsimultaneous dual power input—12 VDC (via poweradapter) and PoE (802.3af)—to ensure continuousoperation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE(802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens |
| 131 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 132 | TELEPHONE |
| 133 | Supply of User Phone- Analog phone |
| 134 | Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 135 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 136 | AIR CONDITIONING UNITS |
| 137 | Supply, Installation, Testing and Commissioning of 1.0TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single-phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature).WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval.Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier |
| 138 | Supply, Installation, Testing, and Commissioning of minimum 1.5TR 3 STAR BEE rated INVERTER type, 4-way cassette split AC units, suitable for single or three phase AC supply. Each unit shall consist of an outdoor unit with a hermetically sealed, suction-cooled, energy-efficient scroll or rotary compressor operating on R-32/ R-410A/ R-407C refrigerant, and a ceiling-mounted, 4-way cassette type indoor unit with a powder-coated, pretreated sheet metal cabinet. The indoor unit shall include an inbuilt drain pump, statically and dynamically balanced blower for silent operation, and synthetic washable media filters arranged for convenient cleaning.Installation shall include power and control cabling in PVC conduits, good quality copper refrigerant tubing with elastomeric nitrile rubber insulation, and an insulated drain line terminated at an agreed drain point. Each unit shall be supplied with a full-function wireless remote control for temperature, mode, and fan speed settings, and a thermostat.The outdoor unit shall be equipped with overload protection, an air-cooled copper condenser coil of sufficient depth and face area, a propeller type fan with a suitable motor, service valves, and a refrigerant filter, all housed in a powder-coated cabinet.WARRANTY: The system must include a MINIMUM 01-year Original Equipment Manufacturer (OEM) warranty for the total machine and a 03-year warranty on compressor. Warranty Certificate to be submitted for approval.Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier |
| 139 | Supply and installation of automatic voltage STABILIZERS suitable for 1.0TR/1.5TR split AC units, complete with all necessary wiring, connectors, and wall mounting hardware. The stabilizer shall feature intelligent microprocessor-based control with SMT/PTH IC technology, ±1% output voltage accuracy, and startup time delay protection. It shall operate within 170V-270V AC input range (50Hz) with auto-reset low/high voltage cut-off, manual-reset thermal overload protection, short-circuit and surge protection |
| 140 | Supply and installation of heavy-duty mild steel (M.S) OUTDOOR STAND for split AC units, comprising of powder-coated mounting brackets with anti-corrosion treatment including all necessary galvanized mounting bolts, nuts, washers, and anchor fasteners. Installation shall be as per manufacturer guidelines and Engineer-in-Charge’s directions, ensuring level alignment with wall/floor mounting options |
| 141 | Supply and installation of insulated PVC condensate DRAIN PIPING for split AC units including wall chasing, solvent-welded joints, and complete with clamps at regular intervals. Installation shall be with adequate slope towards drainage point. Work includes all necessary bends, couplings, P-traps and termination into designated drainage system. |
| 142 | Supply and installation of ADDITIONAL REFRIGERANT PIPING KIT for split AC units, comprising of Seamless copper tubing with wall thickness as per AC manufacturer's specifications, flame retardant elastomeric nitrile rubber insulation of minimum 13mm thickness all including necessary power and control cabling. |
| 143 | Supply, installation, testing, and commissioning of 11.0TR - 4400 CFM, 100mm E.S.P, DX type recirculating factory-built AHUs with 2-stage filtration, 6-row DX cooling coil, double-skin AHU made of 50 mm thick panels consisting of 0.8 mm thick pre-coated GSS on outside, 0.8 mm thick Aluminum sheet inside with factory-injected PUF with a minimum density of 40 kg/m³. The AHU shall be ceiling- or floor-mounted type, single- or double-deck (as per site conditions) along with thermal-break aluminum extruded profile at corners and joints, complete with plug fan compatible with VFD as specified in the starter panel, suitable IE3 class (per IS 12615) TEFC drive motor with IP55 protection suited for 415 ± 10% volts, 50 Hz, 3-phase AC supply, minimum two-bend GSS/PVC eliminators, cooling coil section with aluminum-finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic-type air pre- and fine filters (MERV 8 and MERV 14), mixing box, aluminum VCDs on fresh air, return air, and supply air openings, drain connection, 18 G stainless steel 304 with 19 mm NBR-insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, DX AHU kit, corded remote controller, limit switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254 nm wavelength radiation, 7.5 W/sqft of coil surface area for equal distribution. Heaters (capacity to be proposed by OEM) to be slip-in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, air stat/airflow switch, and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power and control cabling, earthing between AHU/strip heaters and control panel, all supporting GI hangers, MS angles, channels, nuts, bolts, washers, and other necessary items for unit installation shall be included in the scope of supply. Fans shall be Eurovent/AMCA-certified. AHUs shall be Eurovent/AHRI-certified. |
| 144 | Supply, installation, testing, and commissioning of 11.0 TR capacity air-cooled inverter-type outdoor condensing unit with a single- or multi-scroll compressor, as per specifications, complete with a drive motor of suitable capacity, air-cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor-based panel controller with digital display, first charge of R32/R410A/R407C/R134a refrigerant gas, vibration isolation pads, and safety devices including thermal protector, pressure relief valve, overload relays, single- phase preventer, high/low-pressure cutout, suitable for a three-phase 440V supply. |
| 145 | Supply, Installation, Testing, and Commissioning of Unidirectional Laminar Air Flow (LAF) plenum, size 2400 x 2400 mm (8 ft x 8 ft), constructed from 1.2 mm thick SS 304 sheet with a provision/cutout for mounting a swivel light set. The plenum shall be equipped with H14 terminal HEPA filters, tested in accordance with EN 1822, with a minimum efficiency of 99.995% at the most penetrating particle size (MPPS). A perforated, tablet-type stainless steel grill cover shall be provided on the bottom, fabricated from SS 304 with a minimum sheet thickness of 1.0 mm. The cover shall be easily removable as required. The plenum shall include a differential pressure port for measuring the pressure drop across the HEPA filters. The HEPA filter casing shall be aluminum, the media shall be microfiber glass paper, and the bonding shall use PU resin. The fins shall be aluminum, blended type. A polyethylene gasket shall be provided. The pressure drop shall not exceed 25 mm WC. The suspended laminar airflow (LAF) system shall provide Class 100 (ISO Class 5) clean air, as defined by ISO 14644-1.. |
| 146 | Supply and installation of a suitable, CPRI-approved (IEC 61439) AHU VFD starter panel, factory-fabricated, wall-mounted type, including all necessary control and power cable wiring between the AHU and the panel. The motor control shall be facilitated by a variable frequency drive (VFD) complying with the latest IEEE 519 standards. The panel shall incorporate controls such as contactors, overload relays (OLR), single-phase preventer (SPP), control switches, and MCBs for AC units. The panel shall have a 24V AC power supply for fire interlock. The panel shall have an auto/manual selection switch, on/off push buttons, and on, off, and trip indication lamps, etc. The panel shall have control element features, including a humidistat, thermostat, air stat/airflow switch, and safety thermostat, along with control wiring. The panel shall feature ON/OFF switches with indicators and a bypass DOL/star-delta starter (selected based on motor size) for the VFD, along with a manual changeover switch for transitioning between VFD and bypass operations The fan/blower motor shall be interlocked with heaters (where provided) such that the power supply to the heaters will be switched on only after the blower has been started and run to full designed speed. The panel shall have contactors and breakers for the heater banks, with the required power and control wiring to maintain temperature/RH % as per indoor design conditions. |
| 147 | Supply, installation, testing, and commissioning of suitably sized hard drawn copper refrigerant piping (both suction and liquid) including 19mm thick closed cell elastomeric insulation between indoor and outdoor units as per site conditions. Insulation shall be finished with 7 mils of factory laminated fibreglass cloth. |
| 148 | Supply, installation, testing, and commissioning of control/transmission wiring between indoor unit and outdoor unit. Cable must be routed through PVC conduits. Cable sizing shall be as per OEM recommendation. |
| 149 | Supply, storage, installation, testing, and commissioning of 22G (0.8 mm) aluminium ductwork in operation theatres of the specified gauge as appropriate, with all accessories, supports, jointing materials, and flanges, complete; all in accordance with SMACNA standards, the specifications, and drawings. The system shall be complete in all respects for commissioning. |
| 150 | Supply, storage, installation, testing, and commissioning of 20G (1.0 mm) aluminium ductwork in operation theatres of the specified gauge, with all accessories, supports, jointing materials, and flanges, complete; all in accordance with SMACNA standards, the specifications, and drawings. The system shall be complete in all respects for commissioning. |
| 151 | Supply, installation, testing, and commissioning of 32mm dia rigid UPVC condensate drain piping duly insulated with 9 mm thick closed-cell nitrile finished with 7 mils factory-laminated glass cloth, along with necessary U-trap, clamps, fittings such as bends, tees, and other necessary fittings, adequately supported as per site requirements, conforming to tender specifications. |
| 152 | Supply, installation, fixing, and hanging of factory-fabricated fire-retardant flexible canvas connection of minimum 150 mm width at the outlet of each ducted indoor unit with a zipper to facilitate temperature measurement. The fabric shall be made of polyester cloth with black PVC coating on both sides and a galvanized steel seam. |
| 153 | Supply, installation, testing, and commissioning of aluminium volume control dampers, complete with neoprene rubber gaskets, nuts, bolts, screws, linkages, and flanges, in accordance with the specifications and drawings. |
| 154 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Nitrille rubber insulation - 25 mm |
| 155 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper |
| 156 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator |
| 157 | Supply and installation of fresh air/exhaust air louver constructed from powder- coated aluminium with bird screen as per the specifications and drawings. |
| 158 | Supply, fabrication, and installation of return air module (nominal size 22 × 14 inches, or sized as per project design and approved by Engineer-in-Charge) with a 10 micron washable prefilter (MERV 7) and a stainless steel grade 304 grille with a thickness of 1.0 mm and a perforated design (3 – 5 mm holes, 50–70% open area). The module shall include a cowl or flanged connection with EPDM gaskets to ensure airtight integration with the existing return riser duct. The grille and filter shall be removable via hinged or panel access for maintenance and cleaning. |
| 159 | Supply and installation of OT/clean room parameter monitoring system equipped with a touch screen display for the following parameters: room temperature, relative humidity, and differential pressure. The supplied instrument shall be complete with all necessary high-precision sensors, pressure transmission piping, flush-mounted stainless steel enclosures, and other mounting accessories as required. |
| 160 | OT Validation - Validation of all operating theatres (OTs) as per relevant ISO 14644 standards, post-commissioning by performing the following tests using calibrated instruments : a. Temperature and humidity check b. Air particulate count c. Air change rate calculation d. Air velocity measurement at the face of terminal HEPA filtration d. Pressure differential levels relative to ambient/adjoining areas e. HEPA Filter Validation. |
| 161 | Supply and installation of aluminium cladding (26G) for exposed AHU ducting. The cladding shall be weatherproof, with joints sealed using weatherproof silicone sealant. Installation shall ensure no gaps and sealed seams. |
| 162 | Supply and installation of under-deck insulation with 13 mm thick fire-retardant Class 0 nitrile rubber, density 40-60 kg/m³, bonded with manufacturer-recommended synthetic adhesive, and held in position with galvanized steel screws, washers, and cross-braced with 20 SWG galvanized steel wire netting. |
| 163 | CIVIL WORK |
| 164 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 165 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 166 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 167 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 168 | Modular X Ray Viewer |
| 169 | 3rd Year |
| 170 | 4th Year |
| 171 | 5th Year |
| 172 | 6th Year |
| 173 | 7th Year |
| 174 | 8th Year |
| 175 | 9th Year |
| 176 | 10th Year |
| 177 | Modular Surgeon Control Panel |
| 178 | 3rd Year |
| 179 | 4th Year |
| 180 | 5th Year |
| 181 | 6th Year |
| 182 | 7th Year |
| 183 | 8th Year |
| 184 | 9th Year |
| 185 | 10th Year |
| 186 | Modular Anesthesia Pendant |
| 187 | 3rd Year |
| 188 | 4th Year |
| 189 | 5th Year |
| 190 | 6th Year |
| 191 | 7th Year |
| 192 | 8th Year |
| 193 | 9th Year |
| 194 | 10th Year |
| 195 | Modular AGSS Connection with Balancer and Receiver |
| 196 | 3rd Year |
| 197 | 4th Year |
| 198 | 5th Year |
| 199 | 6th Year |
| 200 | 7th Year |
| 201 | 8th Year |
| 202 | 9th Year |
| 203 | 10th Year |
| 204 | High End C-ARM |
| 205 | 3rd Year |
| 206 | 4th Year |
| 207 | 5th Year |
| 208 | 6th Year |
| 209 | 7th Year |
| 210 | 8th Year |
| 211 | 9th Year |
| 212 | 10th Year |
| 213 | AI Enable Patient Monitor |
| 214 | 3rd Year |
| 215 | 4th Year |
| 216 | 5th Year |
| 217 | 6th Year |
| 218 | 7th Year |
| 219 | 8th Year |
| 220 | 9th Year |
| 221 | 10th Year |
| 222 | Modular High End Operating Room Light |
| 223 | 3rd Year |
| 224 | 4th Year |
| 225 | 5th Year |
| 226 | 6th Year |
| 227 | 7th Year |
| 228 | 8th Year |
| 229 | 9th Year |
| 230 | 10th Year |
| 231 | C-Arm Combatable OT Table with Bolsters |
| 232 | 3rd Year |
| 233 | 4th Year |
| 234 | 5th Year |
| 235 | 6th Year |
| 236 | 7th Year |
| 237 | 8th Year |
| 238 | 9th Year |
| 239 | 10th Year |
| 240 | High End Portable Ultrasound |
| 241 | 3rd Year |
| 242 | 4th Year |
| 243 | 5th Year |
| 244 | 6th Year |
| 245 | 7th Year |
| 246 | 8th Year |
| 247 | 9th Year |
| 248 | 10th Year Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy