Tender For Renovation Of Electrical Work And Supply Installation Testing And Commissioning Of Air Conditioning Machine At Fertiliser Quality Control And Soil Testing Laboratories Of Office The Agricultural Chemist, Ground And 1St Floor,230A Nsc Bose, Kolkata-West Bengal
TDR : 55675474
Tender Notice
BOQ
14 Days Left
Kolkata
West Bengal
Tender For Renovation Of Electrical Work And Supply Installation Testing and Commissioning of Air Conditioning Machine At Fertiliser Quality Control And Soil Testing Laboratories Of Office The Agricultural Chemist, Ground And 1St Floor,230A Nsc Bose
Name of Work:- Renovation of Electrical Work and SITC of Air Conditioning machine at Fertiliser Quality Control and Soil Testing Laboratories of office the Agricultural Chemist, Ground and 1st Floor,230A NSC Bose Road, Kolkata 700040-----SITC of Air Conditioning machine.
Sl. No.
Item Description
1
Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. (Make:- O General/Mitsubishi Heavy/Daikin)
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of above AC machines.
4
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above said AC, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (Make- Approved by EIC)
5
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
6
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
7
S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of above AC machines.
8
2.5 sqmm, 3/4 core copper cable (FRLS type) (Make- Polycab/Gloster/Finolex/Havells /RR Kabel as Approved by EIC)
9
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make- Supreme / Oriplast) Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.