| 1 | Part A-Air-conditioning arrangement |
| 2 | Supply of Microprocessor based air-cooled ceiling Concealed type split Air Conditioner comprising of indoor unit,outdoor unit having both condensing and cooling unit made of Cu tubes having cooling capacity not less than 10000W, ISSER ratio:- 3.1 to 3.9, Noise level not more than 55db with scroll/rotary Compressor suitable for R-410A/R-32 Refrigerant & operation on 415V - 50 Hz - 3 Ph AC supply.(Make-Mitshubishi Heavy Industries/O-General /Mitsubishi Electric//Daikin/Carrier ). |
| 3 | Supply & delivery of 240V fixed split Air-conditioner machine having cooling capacity not less than 3500W, ISSER 3.8 to 4.39, highest BEE not less than 3 star rating, Noise level not more than 50db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A.. (Mitsubishi Electric/O-General /Mitshubishi / Hitachi/Daikin/ Mitshubishi Heavy Industries). |
| 4 | Supply & Installation of Extra Add-on items- HVAC grade 5/8\\"(for suction) & 1/4\\"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC. |
| 5 | Supply & Installation of Extra Add-on items- HVAC grade 5/8\\"(for suction) & 3/8\\"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC. |
| 6 | Installation, testing & commissioning of the above-said ACs incl. supply & fixing required Angle Iron Structure on wall for placing outdoor unit & mending good the damages as per direction of E.I.C. |
| 7 | Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC. |
| 8 | Supply & Laying of 4 core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/KEI/Polycab ) |
| 9 | Supply & Laying of 4core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/KEI/ Havells /RR Cable ) |
| 10 | Supply & Laying 20 mm hard PVC pipe (heavy type) for water drainage. |
| 11 | Part B-Electrical Installation work Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Polycab / Gloster /Havells/ Finolex / KEI/RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior/ L&T/ABB as approved by E.I.C) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. [E-24/1] |
| 12 | a) Avg. Run-8mtr |
| 13 | b) On board |
| 14 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Polycab / Gloster /Havells/ Finolex / KEI/RR Kabel) of the following sizes in the prelaid polythene/PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required |
| 15 | i)3 x 22/0.3 (1.5 sqmm) |
| 16 | ii)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 17 | iii) 2x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC |
| 18 | iv) 4x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC |
| 19 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works [E-16/7] |
| 20 | a) 20mm size |
| 21 | b) 25mm size |
| 22 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-9] |
| 23 | i) 2.5sqmm |
| 24 | ii) 4 sqmm |
| 25 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. [E-17/1] |
| 26 | 2 Row 18 Module |
| 27 | 4 Module |
| 28 | Supply & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment , painting and mending good damages to building works. |
| 29 | i) 2 Module |
| 30 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Anchor Roma Classics/Legrand: Myrius/Arterior)with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 31 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Anchor Roma Classics/Legrand: Myrius/Arterior)with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 32 | Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior/ L&T/ABB as approved by E.I.C) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. |
| 33 | Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior/ L&T/ABB as approved by E.I.C) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 34 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior/ L&T/ABB as approved by E.I.C), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 35 | Supply & Fixing 240 V, 6/16 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior/ L&T/ABB as approved by E.I.C), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 36 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length |
| 37 | Supply of 4'ft LED Twin batten/Metal frame fittings incl. 2nos. 18W Polycarbonate/Aluminium LED tube having luminoius efficacy of 100lm/W [Philips/Crompton/ Wipro or manufacturer with own NABL accredited Lab with valid Test certificate as approved by E.I.C] |
| 38 | Supply of 18''(450 mm) Sweep heavy duty best quality AC Wall Bracket Full metal body Fan |
| 39 | Supply of 225 mm Light duty Full metal body Exhaust Fan (Make : Orient / Crompton / EPC ) |
| 40 | S&F of 32A timer controlled DB for 1 no. single phase AC in SS double door 12 way DB enclosure (Make: L&T/Legrand/ABB(E)) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish. All connections should be made by copper wire of 4mm2 & 1.5mm2 and finishing with dowells solderless socket by crimping method incl. necy. connection & provision for earthing attachment incl. Ferruling & marking with S&F following Electrical accessories as per direction of EIC [for 2/1.5 TR AC]i) 240V, 32A DPMCB C curve breaking capacity 10kA - 1 no.ii) 240V, 22A, 2P Contactor with Auxilary Contact - 1 no.iii) 25A, 250V AC ON-OFF-ON SPDT toggle switch with marking-1no. (for Auto/Manual option).iv) 24Hr x 7 days programmble Digital timer - 1 no.v) On & Off Indicator LED lamp and Start & Stop push button switch (G&R)-2 set.vi) Din rail mounted Terminal Block for Outgoing & Incoming - 4 nos.vii) 6-32 A SP MCB C curve breaking capacity 10kA-1 no. |
| 41 | S&F of 32A timer controlled DB for 1 no. three phase AC in SS double door 14 way DB enclosure (Make: L&T/Legrand/ABB(E)) with IP-42/43 protection, on wall & mending good the damages to original finish. All connections should be made by copper wire of 4mm2 & 1.5mm2 and finishing with dowells solderless socket by crimping method incl. necy. connection & provision for earthing attachment & neutral link incl. Ferruling & marking with S&F following Electrical accessories as per direction of EIC [for 3/4 TR AC]i) 415V, 32A FPMCB C curve breaking capacity 10kA - 1 no.ii) 415V, 32A, 3P Contactor with 1 no + 1 no Auxilary Contact - 1 no.iii) 32A, 250V AC ON-OFF-ON SPDT toggle switch with marking-1no. (for Auto/Manual option).iv) 24Hr x 7 days programmble Digital timer - 1 no.v) On & Off Indicator LED lamp and Start & Stop push button switch (G&R)-2 set.vi) Din rail mounted Terminal Block for Outgoing & Incoming - 7 nos.vii) 6-32 A SP MCB C curve breaking capacity 10kA-1 no. |
| 42 | Supply & fixing automatic single phase AC starter of 21Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on wall with all fixing accessories complete as to G.S |
| 43 | S & F 3phase, 415 V, 50Hz DOL starter with encloser Relay range 9-14 amps (Make-ABB/Siemens/L & T as per dierction of E.I.C) to be fixed on wall with all fixing accessories complete as to G.S |
| 44 | Supply & laying 1.1 KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(make: Havels/KEI/Polycab/Finolex as per approved by EIC) |
| 45 | Supply & fixing of Indicator for modular box |
| 46 | Supply & fixing of Blank Plate for modular box |
| 47 | Supply & Fixing 240 V, 25A Modular switch type SP MCB (C-Curve) (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 48 | Supply and Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/ perspex top cover incl. making necy. connections etc. |
| 49 | Dismantling existing old Electrical wiring, celing fan , light etc with owns tools & takles incl. mending good damages as per GS and clearing/removing from the site. |
| 50 | Part C-Glow Sign Board Installation Arrangement |
| 51 | SITC of LED signboard with Steel/ Acrilyc letters on ACP Board as such LED fixed inside the steel/Acrilyc letters on ACP board( Preferable size of the 3 nos board-i) 12'x5'x3/4' or other suitable size to accommodate all the matters / contents as approved by the authority). The main structure board is to be made with 25x25x4mm MS angle iron ,18 SWG square/round hollow bar , Base plate (10mm thickness) required for fixing the necy. nos nuts , bolts washers, supporting angle iron. Clamp etc. and ACP sheet on all sides to be moulded uniformly of the board to be provided. |
| 52 | actual Letter contents/Govt. LOGO/actual etc. sign will be executed as per approval of the authority) |
| 53 | Overall size of LED sign ACP board will have to be in the shape to accommodate all the letter contents/signs as approved by the Authority |
| 54 | Steel letters and front side Acrilyc cover on ACP board, Thickness : 05 mm (Make: samsang/ISI Approved) |
| 55 | Letter : Size of 8\\"/ 9\\" / 12\\"/15\\"/18\\" for different word/Text according to actual requirement as per direction of E.I.C, Colour : white / red/ blue or any other colour as approved by the authority/E.I.C |
| 56 | Necessary Electronic Diver / power supply device to be fixed in the ACP or suitable places |
| 57 | Intensity : Same & smooth uniform throughout without any dark patch |
| 58 | Visibility : upto 250 meters for normal eyes |
| 59 | Suitable copper wire laying through PVC rigid or flexible pipe & terminal connection as per direction of the EIC. |
| 60 | SITC of LED signboard with Steel/ Acrilyc letters on ACP Board as such LED fixed inside the steel/Acrilyc letters on ACP board( Preferable size of the 3 nos board-i) 12'x5'x3/4' or other suitable size to accommodate all the matters / contents as approved by the authority). The main structure board is to be made with 25x25x4mm MS angle iron ,18 SWG square/round hollow bar , Base plate (10mm thickness) required for fixing the necy. nos nuts , bolts washers, supporting angle iron. Clamp etc. and ACP sheet on all sides to be moulded uniformly of the board to be provided. |
| 61 | actual Letter contents/Govt. LOGO/actual etc. sign will be executed as per approval of the authority) |
| 62 | Overall size of LED sign ACP board will have to be in the shape to accommodate all the letter contents/signs as approved by the Authority |
| 63 | Steel letters and front side Acrilyc cover on ACP board, Thickness : 05 mm (Make: ISI Approved) |
| 64 | Letter : Size of 8\\"/ 9\\" / 12\\"/15\\"/18\\" for different word/Text according to actual requirement as per direction of E.I.C, Colour : white / red/ blue or any other colour as approved by the authority/E.I.C |
| 65 | Necessary Electronic Diver / power supply device to be fixed in the ACP or suitable places |
| 66 | Intensity : Same & smooth uniform throughout without any dark patch |
| 67 | Visibility : upto 250 meters for normal eyes |
| 68 | Suitable copper wire laying through PVC rigid or flexible pipe & terminal connection as per direction of the EIC. |
| 69 | Add. G.S.T.@ 18% on total value. |
| 70 | Add. LWC.@ 1% on total value Please Enable Macros to View BoQ information |