| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | i) Average run 6 mtr |
| 3 | ii)Average run 8 mtr |
| 4 | On Board |
| 5 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the 20mm/25mm size PVC rigid conduit FR(Precision make) incl. Necy fittings as required (Make : RR/Polycab/ Finolex/ Havells) |
| 6 | i) 3 x 22/0.3 (1.5 sqmm) |
| 7 | ii) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 8 | iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 9 | iv)2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC ( TPNDB to SPNDB ) |
| 10 | v) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC ( VTPN to TPNDB ) |
| 11 | Supplying & Fixing sheet metal inspection box (16 SWG) with top cover bakelite / perspex using brass screw of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 12 | A)150 mm x 100 mm x 65 mm |
| 13 | B)200 mm x 150 mm x 65 mm |
| 14 | Cutting Channel of following size on masonry wall by Electric operated cutting machine incl. supplying & fixing of following heavy gauge polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles |
| 15 | 19 mm dia 3 mm thick polythene pipe without earthcontinuity wire |
| 16 | 25 mm dia 3 mm thick polythene pipe without earthcontinuity wire |
| 17 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. |
| 18 | 20mm size |
| 19 | 25mm size |
| 20 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/Seimens/Schneider) up to 160A |
| 21 | i) 8 way Enclosure ,Up to 160A |
| 22 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/Seimens/Schneider) |
| 23 | i) 6 way Enclosure |
| 24 | ii) 8 way Enclosure |
| 25 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make- Legrand/Seimens/Schneider) |
| 26 | i) 2+8 way Enclosure |
| 27 | ii) 2+12 way Enclosure |
| 28 | Supplying and fixing 240V SP MCB of Breaking apacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make- Legrand/Seimens/Schneider) |
| 29 | i) 6-16 A |
| 30 | ii ) 40 A SP |
| 31 | Supplying and fixing 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/Seimens/Schneider) |
| 32 | i) 63 A |
| 33 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection. (Make- Legrand/Seimens/Schneider) |
| 34 | i) 63 A FP |
| 35 | ii) 40 A DP |
| 36 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make- Legrand/Seimens/Schneider) |
| 37 | i) 160 A FP |
| 38 | PLUG, SOCKET, POWER PLUGS & AC POINT |
| 39 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch,indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 40 | Supply & Fixing of Two Nos 240 V, 6A, plug socket with separate Two Nos 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. |
| 41 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board |
| 42 | Supplying and fixing 240V, 25A, AC OLP 3+ starter making necessary connections with PVC cu wire and earth continuity wire etc. Incl supply & fixing 175mm x 100mm GI Box compl flushed in wall with voltage check , amp check incl all connection & mending good the damages (Make-Electron OLP 3+) |
| 43 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 44 | CABLE AND LAYING |
| 45 | Supply and delivery of following size PVC/A(AL) cable. (Make-Polycab/ RR kable/Havells) |
| 46 | a) 4 core 70sqmm (From Panel to VTPN DB) |
| 47 | Supplying and fixing 4 core compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 48 | a) 4 core 70sqmm |
| 49 | Finishing of the XLPE/PVC insulated armoured cable ends by crimping method with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. |
| 50 | 4 core 70sqmm |
| 51 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 52 | i) 2.5 sq mm |
| 53 | ii) 4 sq mm |
| 54 | iii) 6 sq mm |
| 55 | iv) 10 sq mm |
| 56 | v) 16 sq mm |
| 57 | CABLE & TRAY |
| 58 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI Connector, 8mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support |
| 59 | With 40x40x6mm angle iron support 300x50x1.25mm (18SWG). |
| 60 | Supply & Fixing of following perforated GI cable tray fittings with perforation notmore than 17.5% suspended from ceiling with two nos. suspenders& 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fasteneretc. as required of the following size. Incl. Al painting of MS support. |
| 61 | 300x50x1.25mm (18SWG) (Bend). |
| 62 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. |
| 63 | a)From 70 sqmm Up to 150 sqmm |
| 64 | Fittings Fixture |
| 65 | Supply & Delivery of following LED Industrial Batten light (System lumen efficacy 2110 Im/Watt) made of CRCA Sheet Body (Thickness > 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap), Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range Oo to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection . |
| 66 | ITHD < 10% , P. F.20.95, P20, CRI >80, Flicker free, (Ricker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 40000 Burning Hours, with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). |
| 67 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. LM79 & LM8O Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 ° C) |
| 68 | i) Single Batten Fittings (1 x 18/20 Watt) |
| 69 | ii) Double Batten Fittings (2 x 18/20 Watt) |
| 70 | Supply & Delivery of 240V, 18/ 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 71 | Supplying, installation, Testing & Commissioning of 230V, 1-phase AC ceiling fans incl. all accssories, the capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan, complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [Make: Crompton/Usha/Havells/Orient] Sweep Size- 1200 mm (48\\"), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M |
| 72 | Supplying, installation, Testing & Commissioning of 230V, 1-phase AC exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust fan of following diameter, complete as required.[Make: EPC/Crompton/Usha/Havells/Orient] |
| 73 | 230 mm (9\\"), 4 Blade, RPM ≤ 1370 , Wattage ≤ 40 Watt, Sound level ≤ 49 dB, Air Displacement (In CFM) ≥ 440 |
| 74 | Fittings & Fixture |
| 75 | Fixing only single/Twin fluorescent/LED light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. |
| 76 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 77 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 78 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 79 | i) 23 cm (9\\") |
| 80 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)for GI |
| 81 | 23 cm(9'') |
| 82 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.(E-6/18(a)) |
| 83 | AIR CONDITIONING SYSTEM |
| 84 | S&D of split type AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (5.2 KW - 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable with 25 A Plug Top for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas) |
| 85 | S&D of minimum High Wall inverter type Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with Rotary Compressor with minimum Cooling Capacity of (6.6KW-7.00 KW), Air flow rate (630-875) CFM, suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wireless remote & all other accessories complete with refrigerent with 25 A Plug Top (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/Sharp/ Mitsubishi Heavy/Voltas) |
| 86 | Installation Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC Machine after making hole in wall etc as per direction of EIC including making arrangement for outdoor unit by suitable size angle iron frame as per direction of E.I.C |
| 87 | Supply and drawing 5/8\\" & 3/8\\" or 1/2\\" & 1/4\\" copper refrigerant pipes with 9 mm thick rubber nitrile rubber insulation an Al foil tape complete fittings Elbows, Bends, Supporting arrangement on walls along with other accessories on the surface of wall. |
| 88 | Supply and laying of 1.1 KV single core stranded 'PVC insulated FRLSH grade copper cable incl socketing, shaddling etc.as per direction of EIC ( Make : Finolex/ Havells/ Polycab/ RR or Brand approved by EIC) of requisite following diameter for the above Air-Conditioners as per direction of Engineer - In - Charge incl. necy. fittings as required as per G.S . [Power cable for connection betweeen indoor and outdoor units & also Control Cable for connection betweeen outdoor units to indoor ] |
| 89 | i) 3 core x 4.0 mm² Round PVC insulated copper cable |
| 90 | Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of 25 mm dia. incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. |
| 91 | Supplying and fixing of 250 V AC Timer Fixed on wall with flat iron frame as per direction of EIC. The Box shuld comprising following accessorise... A) Double-door SPN MCB Distribution Board with IP-42/43 protection. 2+8 Way Make-Legrand, CAT No- 607711) as to GS B)250V, 50 Hz,16 Amp One no Digital Clock. C) 250V,40A 2 NO Conctractor.(Make-Legrand or as to EIC E) 240V, 40 A DP Changeover MCB. (Make- Legrand) or as to EIC F) Diode type neon indicator lamp-1 no G) The complete arrangement must be wiring by 2.5 sqmm PVC insulated Cu wire with suitable socket/lugs as per requirment & direction of EIC. (Make: L&K / Legrand/ABB/Seimens ) Please Enable Macros to View BoQ information |