| 1 | Disconnection & dismantling existing old fittings and clearing/removing from the site and deposit the same to the authority as directed by EIC. (considering 1 no semi-skilled & 1 no helper for 1 day) |
| 2 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (System lumen efficacy ≥135 lm/Watt) (Make: Signify / Crompton / Wipro) |
| 3 | 150 watt |
| 4 | Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driverefficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (System lumen efficacy ≥135 lm/Watt.) (Make: Signify / Crompton / Wipro) |
| 5 | 150 Watt |
| 6 | Fixing only Street/Flood Light Fitting on wall/ceiling by screws etc with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. |
| 7 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells/Polycab/RR Kabel) of the following sizes with polythene pipe(19mm dia 3mm thick) and GI fish wire and making necy. connection as required |
| 8 | i) 3x22/0.3(1.5sqmm) |
| 9 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 10 | i) 20mm size |
| 11 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 6 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 12 | Supply & fixing Timer Control unit for compound light in SS double door (lP-43) 12way SPNDB Box [Make-L&T / Siemens/ Legrand/ ABB as approved by E.l.C [with all accessories on wall with fastners, nuts etc.] a) 12-way SPNDB or Timer DB -1 no. (b) 40 A DPMCB Isolator -1 no.c) 25 A 2 Pole Power Contactor -1 nod) Daily & weekly programmable digital time switch--1 no.e) LED lndicator lamp-2 Set(1- Red & 1-Green)f) 32 A Barrier type Terminal---1 No.(g) Centre off 2-way toggle switch---1 no.All control circuit wiring would be made by 2x4 + 1x2.5 sqmm FRLS stranded Cu wire (Make:- Gloster/Havells/Polycab/RR Kabel) of suitable length maintaining colour code incl. taping, socketing to complete the work. |
| 13 | Supply & delivery of 24 hr digital time switch (Make L&T Cat No. 67DDT0 or equivalent) Please Enable Macros to View BoQ information |