| 1 | TOTAL |
| 2 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately).Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. |
| 3 | Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr. |
| 4 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 5 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.upto 150 mm. thick |
| 6 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required Depth of excavation not exceeding 1,500 mm. |
| 7 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. (Ground floor) |
| 8 | 1st floor |
| 9 | 2nd floor |
| 10 | 3rd floor |
| 11 | Cutting chase upto 125 x 150 mm. and subsequent mending of damages.In brick wall [Cement-3.6 Kg/Mtr] |
| 12 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 13 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. |
| 14 | Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including mending good damages and finishing the surface to match with adjacent areas complete as per direction.With reinforced cement concrete blocks (1:1½:3) with stone chips and nominal reinforcement.Block size 250 x 125 x 150 mm. |
| 15 | Brick work with 1st class bricks in cement mortar (1:4)In superstructure, ground floor |
| 16 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy. |
| 17 | Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1. |
| 18 | Applying epoxy mortar ( 10 mm nominal thick) over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical specification |
| 19 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.Pakur Variety |
| 20 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/Mild Steelground floor |
| 21 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 22 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). |
| 23 | Applying 2 coats of bonding agent with synthetic multi functional ubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the epartment] |
| 24 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment] |
| 25 | Guniting concrete surface with cement mortar (25 mm nominal thick) applied with compressor after cleaning surface and spraying with epoxy complete as per Technical specification. |
| 26 | Supplying. preparing and placement of ready mix non shrink cementious microconcrete having no metalic aggregate or chlorides for repairing and \iackting of damagedR.C.C.members.The micro concrete should achieve a compressive strength not less than 10 MP after 24 hours. 40 Mp after 7 days 3 and 50 Mp aftre 28 days at 300C.It should have unrestrained expansion in between 1 to 4%. flexural strength shall not be less than 5MP after 28 days. Micro concrete should have a co-efficient of thermal expansion similar to that of the host concrete. |
| 27 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes |
| 28 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)Upto area 2.5 Sq.m |
| 29 | Supplying and application of chemicalfor rebar anchoring by using ETA approved/Or seismic criteriain rebarconnection, Including drilling hole to the required depth by rotary hammer drill,cleaning with brush& jet of clean air, IPlllng resin and hardener using serrated nozzle to eliminate mixing error and In a voldlessmanner Includingchargesfor all tools & plants. Applicationto be \\"0: designedfor rebars as per ECZ/TR023or relevant tested and accepted design IS guidelinesand the design document to be furnished by the manufacturer.The chemicalshould have ETAapprovalfor seismic criteriaof rebarfixing which should be furnished by manu/Octurer. The installation and the setting instructionsshould be strictly followed as per manufacturer'sspecificationsas approved by EICprior to drilling. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement inconcrete |
| 30 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar includingPlaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chippingWith 1:4 cement mortar20 mm thick plaster (ground floor) |
| 31 | 1st floor |
| 32 | 2nd floor |
| 33 | 3rd floor |
| 34 | 4th floor |
| 35 | 15 mm thick plaster |
| 36 | 1st floor |
| 37 | 2nd floor |
| 38 | 3rd floor |
| 39 | 10 mm thick plaster ground floor |
| 40 | 1st floor |
| 41 | 2nd floor |
| 42 | 3rd floor |
| 43 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.FLOOR Area of each tile upto 0.09 Sq.mColoured decorative |
| 44 | 1st floor |
| 45 | 2nd floor |
| 46 | 3rd floor |
| 47 | WALL Area of each tile upto 0.09 Sq.mColoured decorative |
| 48 | 1st floor |
| 49 | 2nd floor |
| 50 | 3rd floor |
| 51 | Cutting joints of existing floor and wall (Granite /Marble / Tiles etc. by 3 mm wide and 7 mm deep asnd filling the joints with 100 % stain free, chemical and temperature resistant, anti- bacterial and anti fungal epoxy grout with approved manufacturer to match etc. |
| 52 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).Sal: Local |
| 53 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. 66mm x 90mm |
| 54 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor.32 mm thick |
| 55 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.35mm thick shutters with 19mm thick panel of size 30 to 45 cm. Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. |
| 56 | Glazed shutters of doors, windows, fan light, clerestory windows etc. as pe design (with ordinary glass of 7.4kg./sq.m. 3mm. Thick) fitted with putty bed and teak wood bead and nails including fitting and fixing shutter in position but excluding the cost of hinges and other fittings. cost of glass, putty, wooded beads etc.will be paid separately. 35mm thick shutters. Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. |
| 57 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 125mm Length |
| 58 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.100mm. X 50mm. X 1.25mm. |
| 59 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:150mm long x 10mm dia. bolt. |
| 60 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:100 mm grip x 12 mm dia rod. |
| 61 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. |
| 62 | Supplying fitting and fixing I.R.C. fabric mesh with covering battens including cost of screws etc complete (excluding the cost of battens).In ground floor. 75mm x 25mm x 4.5mm x 2.7mm. |
| 63 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. |
| 64 | Reparing collapsible gate by cutting out all rivets as necessary reassambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting in position and painting two coats. |
| 65 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).In 10-12 Micron thickness Annodizing filmnatural white 2- track sliding windowBottom frame |
| 66 | top & side member |
| 67 | Shutter for all track sliding window.Bottom and top member |
| 68 | Style side member. |
| 69 | Interlock member. |
| 70 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.For sliding windows'U' shaped EPDM gasket for frames. |
| 71 | Supplying PVC rollers for sliding windows as per direction of Engineer in charge. |
| 72 | Supplying maruti lock (100mm) |
| 73 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) |
| 74 | Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC.The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers.) 2 track sliding window. |
| 75 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge. |
| 76 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement@160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). |
| 77 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 78 | Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 79 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and einforcement,if any, in ground floor as per relevant IS codes.Pakur Variety |
| 80 | Supplying & laying 25 mm thick Tiles of any shade of approved quality as per relevant IS code, of any shade of approved quality as per relevant IS code 1237-2012 laid in pattern as directed footpath,ramp,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department). in all respect with all labour and material.[Border concrete if necessary to be paid separately].Note: Sub-grade CBR should not be less than 5.Colour decorative |
| 81 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 82 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.Two coats In ground floor |
| 83 | 1st floor |
| 84 | 2nd floor |
| 85 | 3rd floor |
| 86 | 4th floor |
| 87 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) |
| 88 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.two coats (ground floor) |
| 89 | 1st floor |
| 90 | 2nd floor |
| 91 | 3rd floor |
| 92 | 4th floor |
| 93 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)Premium 100% Acrylic Emulsion |
| 94 | 1st floor |
| 95 | 2nd floor |
| 96 | 3rd floor |
| 97 | 4th floor |
| 98 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two Coats |
| 99 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 100 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 101 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary :On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 102 | On steel or other metal surface :With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 103 | Post constructional measures :- Anti-termite treatment to the outside of foundations with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1%concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemicaln emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III) 1981. |
| 104 | Post constructional measures :- Anti-termite treatment to the soil under floor with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight including drilling vertically 12mm. dia holes at the junction of floor and wall at 300mm. interval to reach the soil below using hand operated pressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealedafter operation to match with the existing floor. The entire work is to be carried out as per specification laid down in para 4.3.1.4 of code I.S.-6313 (Part-III)- 1981. |
| 105 | Spot application for insecticides using Aqua base spray for pest (for bugs, cockroaches, silverfish, spider, termites, mosquitoes) to walls and ceiling etc. with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) withwater by weight including spraying the emulsified chemical @ 0.5 litres per sq.m. by a hand operated pressure pump on wall surfaces, ceiling, electrical fixture,electrical lines including drilling holes inplaces where source of termite is detected squirting chemical solution into the holes and sealing the holes with cement grout. (Rate is per sq.m. of the floor area while actual work will be all walls ceiling, rack, partition and furniture). |
| 106 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/ Bitumen /M-Seal etc) complete.UPVC pipes: 110 mm dia |
| 107 | UPVC fittings plain tee 110 mm dia |
| 108 | Shoe 110 mm dia |
| 109 | S & P works Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992Single Socketed 3 Meter Length110 mm |
| 110 | Single Socketed 1.8 Meter Length110 mm |
| 111 | Double Socketed 0.9 Meter Length110 mm |
| 112 | Fittings plain tee 110 mm |
| 113 | Door tee 110 mm |
| 114 | Bend 87.5º110 mm |
| 115 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.Above ground 110 mm dia |
| 116 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.With 'P' trap (with vent) |
| 117 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing).580 mm X 440 mm |
| 118 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.Anglo Indian Plastic (hallow type) white |
| 119 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 120 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)For Exposed WorkPVC pipes (15 mm ) |
| 121 | 20 mm |
| 122 | 25 mm |
| 123 | 40 mm |
| 124 | 50 mm |
| 125 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 470 mm X 280 mm X 340 mm |
| 126 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.550 mm X 400 mm size |
| 127 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.750 mm long |
| 128 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.900 mm long |
| 129 | Supplying, fitting and fixing bib cock or stop cock.Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 130 | Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 131 | Supplying, fitting and fixing pillar cock of approved make.CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 132 | PTMT Pillar Cock - 15 mm. (Prayag or equivalent). |
| 133 | Supplying, fitting and fixing shower of approved brand and make.PTMT overhead shower ( Prayag or equivalent)150 mm round |
| 134 | Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 135 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.450 mm X 300 mm |
| 136 | Supplying, fitting and fixing towel rail with two brackets. C.P. over brass25 mm dia. and 450 mm long |
| 137 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007Ball valve |
| 138 | 40 mm |
| 139 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.)50 mm dia |
| 140 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.With Pakur variety. (SAIL/TATA/RINL)With Manhole Cover |
| 141 | Extra for each additional depth of 150 mm or part thereof beyond initial 600 mm depth. |
| 142 | Without Manhole Cover |
| 143 | Extra for each additional depth of 150 mm or part thereof beyond initial 600 mm depth. |
| 144 | Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master traponly).900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved makeWith Pakur variety |
| 145 | Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for non-pressure underground Drainage, Sewerage & Cross drainageapplication.300mm internal dia. |
| 146 | 200 mm intertnal dia |
| 147 | Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S- 12592(M.D)5 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of sizeCover: 565 mm X 65 mmFrame: 665 mm X 125 mmopening: 470mmWeight: 90 kg (approx) |
| 148 | 1 MT load bearing capacity round manhole cover provided with two lifter hook with matching frame of sizeCover: 450 mm X 40 mmFrame: 540 mm X 80 mmopening: 360mmWeight: 34 Kg. (approx) |
| 149 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m) |
| 150 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 151 | Sub Total |
| 152 | GST @ 18% |
| 153 | Cess @ 1% |
| 154 | Add GST @ 18% |
| 155 | Add Labour Welfare Cess @ 1% |
| 156 | Supplying, fixing and testing of ABC dry powder (Stored Pressure) Fire Extinguisher ISI Marked of 6 kg capacity consisting of welded cylinder, squeeze lever discharge value fitted with pressure indicating gauge internal discharge tube, discharge nozzle suspension bracket, with ISI Marked Mono Ammonium Phosphate base (50%) ABC Power confirming to IS 4308:2019(W.E.F. 16.7.19) pressurized with Nitrogen Gas, suitable for operating between – 30 degree C to +60 degree C minimum, Fire Rating Class-3A & 89B. The colour of the extinguisher body sholud be PO Red confirming to shade 538 of IS 5 with blue colour sticker pasted to indicate power type for easy recognition. The complete extinguisher should confirm to IS: 15683:2018 and should be maintained as per IS 2190-2024 Code of practice. Exinguishers to be refilled/hydro test for performance once in 5 yrs. A Polyester with 3D hologram label of OEM(Original Equipment Manufacturer) should be pasted on the body of the extinguisher showing:1. Supplied by: PWD2. Date of manufacture:3. Date of expiry / date of next filling:4. Serial No:5. Brand Name:(Minimax/Ceasefire/Safex/Fire Shield.) |
| 157 | Supplying, fixing and testing of ISI Marked Co2 type confirming to IS: 15222:2002) Fire Extinguisher 4.5 Kg. capacity confirming to IS: 15683:2018 made from seamless cylinder confirming to IS:7285 duly approved by Chief controller of Explosive, Nagpur, fitted with ISI marked controlled valve confirming to IS:3224, high pressure 1mtr. Long discharge hose and horn with shock proof rubber grip to prevent from frost bite while operating, complete with initial gas charged with carrying handle and wall mounting bracket, suitable for operating between – 30 degree C to +60 degree C minimum, Fire Rating Class -34B. The colour of the extinguisher body should be PO Red conforming to shade 538 of IS 5 with Black Colour Sticker pasted to indicate CO2 type for easy recognition. The Complete Extinguisher should conform to IS: 15683 : 2018 & should be maintained as per IS:2190:2024 Code of Practice. Extinguishers to be Refilled / Hydro test for performance once in 5 years.A Polyester with 3D hologram label of OEM (Original Equipment Manufacturer) should be pasted on the body of the extinguisher showing:1. Supplied by: PWD2. Date of manufacture:3. Date of expiry / date of next filling:4. Serial No:5. Brand Name:(Minimax/Ceasefire/Safex/Fire Shield.) Please Enable Macros to View BoQ information |