| Sl. No. | Item Description |
| 1 | Supplying and fixing 6 Way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting& 415 V TP MCB on din rail of it and necessary connection as required. Incoming - 125 A FP MCCB --1 no'soutgoing--63A TP MCB of Breaking capacity 10kA & C characteristics--6 no'sMake-Legrand/ABB/LK |
| 2 | Supplying and fixing 4 Way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Incl. Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting& 415 V TP MCB on din rail of it and necessary connection as required. Incoming - 100 A FP MCCB --1 no'soutgoing--63A TP MCB of Breakingcapacity 10kA & C characteristics--4 no'sMake-Legrand/ABB/LK |
| 3 | Supplying and fixing double door sheet steel(16SWG), powder coated cable end box for 4 way & 6 way VTPN DB enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. Make-Legrand/ABB/LK |
| 4 | Supplying and fixing double door 6 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Incl. Supplying and fixing 240 V MCB Isolator/MCB on din rail of it and necessary connection as required. Incoming - 63 A FP MCB Isolator --1 no'soutgoing--6-16A SP MCB of Breakingcapacity 10kA & C characteristics--18 no'sMake-Legrand/ABB/LK |
| 5 | Supplying and fixing double door 4 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Incl. Supplying and fixing 240 V MCB Isolator/MCB on din rail of it and necessary connection as required. Incoming - 63 A FP MCB Isolator --1 no'soutgoing--6-16A SP MCB of Breakingcapacity 10kA & C characteristics--12 no'sMake-Legrand/ABB/LK |
| 6 | Supplying and fixing 2 + 10 way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Incl. Supplying and fixing 240 V MCB Isolator/MCB on din rail of it and necessary connection as required.Incoming - 40 A DP MCB Isolator --1 no'soutgoing--6-16A SP MCB of Breakingcapacity 10kA & C characteristics--10 no'sMake-Legrand/ABB/LK |
| 7 | Supplying and fixing 415V, TPN SFU with sheetsteel enclosure on angle iron frame on wallwith nuts bolts etc incl. S & F 3 nos. DIN type HRCfuse as per rating and Cable end box at both end100A Make -Legrand/ABB/LK |
| 8 | Supplying and fixing 415V, TPN SFU openexecution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.125A Make -Legrand/ABB/LK |
| 9 | Supplying and fixing 415V, TPN SFU with sheetsteel enclosure on angle iron frame on wallwith nuts bolts etc incl. S & F 3 nos. DIN type HRCfuse as per rating. And Cable end box at both end415 A Make -Legrand/ABB/LK |
| 10 | Supplying and fixing 415V, TPN SFU openexecution in existing SS enclosure/cubical with nutsbolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.200 A Make -Legrand/ABB/LK |
| 11 | Supply & fixing 240 V 25ATimer controller for AC machine in SS double door (2+10) way DB enclosure with IP-43 ( Make-L&T ) or equivalent with S&F following electrical accessories & front door key locking arrangement with all connection by finishing the ends of 2 x 4 & 1 x 2.5 copper wire dowels solder less socket by crimping method as to GS earthing attachment on wall Inc. Necessary connections as per direction of EIC:- i) 10kA C-curve,240V 25A DP MCB (LK/Schindler/ABB)---1 no. ii) 24 Hr programmable digital time switch(LK/Schindler/ABB)---1 no. iii) 2 pole power contractor (LK make cat no MNX22/230) ----1 set iv) LED indicator( Red/Green) ---- 1 Set v) 3 Module plate with cover-----1 no. vi) 20A auto-off-bypass SPDT toggle switch(Approved make/reputed make)-----1 no. vii) 10 A Modular type switch-----1 no. viii) Outgoing connection make ELMAX(Approved make)-----1 noix) Modular starter 25A --- 1 No |
| 12 | Supply of 4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] |
| 13 | 4 core 120 sqmm. |
| 14 | 4 core 70 sqmm. |
| 15 | 4 core 50 sqmm. |
| 16 | 4 core 25 sq.mm. |
| 17 | Supply of 1.1 KV grade PVC insulated unarmoured Cu Cable of the following size [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] |
| 18 | 1 Core 95 sqmm (475/0.50) |
| 19 | 1 Core 240 sqmm (1221/0.50) |
| 20 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 21 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 22 | Laying of cable above 4 core 50 sqmm and upto 4 core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 23 | Laying of cable above 4 core 90 sqmm and upto 4 core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 24 | Laying of cable as below, on existing Cable Tray and binding withsuitable size GI wire. |
| 25 | Up to 50 sqmm |
| 26 | From 70sqmm to 150sqmm |
| 27 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 28 | 4 Core 25 sqmm |
| 29 | 4 core 50 sqmm |
| 30 | 4 core 70 sqmm |
| 31 | 4 core 120 sqmm |
| 32 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 33 | 4 Core 25 sqmm |
| 34 | 4 core 50 sqmm |
| 35 | 4 core 70 sqmm |
| 36 | 4 core 120 sqmm |
| 37 | 1 Core 95 sqmm (475/0.50) |
| 38 | 1 Core 240 sqmm (1221/0.50) |
| 39 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 40 | 200x50x1.25mm (18SWG) With 25x25x3mm angle iron support |
| 41 | 300x50x1.25mm (18SWG)With 25x25x3mm angle iron support |
| 42 | Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support |
| 43 | 200x50x1.25mm (18SWG) |
| 44 | 300x50x1.25mm (18SWG) |
| 45 | Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 46 | 200x50x1.25mm (18SWG) |
| 47 | Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Polycab/ Havells/ Gloster) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required |
| 48 | 3 x 22/0.3 (1.5 sqmm) |
| 49 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 50 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 51 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 52 | Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Polycab/ Havells/ Gloster) in 20/25/40 mm size PVC rigid conduit 'FR' (Precision/Polycab make, MMS/HMS type) incl. necy. fittings as required |
| 53 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 54 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 55 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 56 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 57 | Supplying and fixing 20 mm PVC Rigid Conduit 'FR' [Precision/Polycab make, MMS/HMS type] on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 58 | Finishing of the PVC insulated wire ends by socketing with pin/ ring type copper sockets (Make:Dowels) and insulated tapes etc., including supplying sockets, tapes. |
| 59 | 3 x 22/0.3 (1.5 sqmm) |
| 60 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 61 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 62 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 63 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Polycab/ Havells/ Gloster) in 20mm size PVC rigid conduit 'FR' (Precision/Polycab make, MMS/HMS type), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch (Black or white as directed by EIC) fixed on MS CRC sheet metal (16 SWG) switch board (Make:Anchor) cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching colour) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish |
| 64 | Average run 8 mtr |
| 65 | On Board |
| 66 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire(Polycab/ Havells/ Gloster) partly in 20mm size PVC rigid conduit 'FR' (Precision/Polycab make, MMS/HMS type) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC)(Black or white as directed by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed](Make -Legrand Myrius/ Schneider / Approved make) |
| 67 | Average run 8 mtr |
| 68 | On Board |
| 69 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Polycab/ Havells/ Gloster) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make)(Black or white as directed by EIC) fixed on sheet metal (16 SWG) switch board (Anchor make) with bakelite/Perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 70 | Average run 8 mtr |
| 71 | On Board |
| 72 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Polycab/ Havells/ Gloster) in 20mm size PVC rigid conduit 'FR' (Precision/Polycab make, MMS/HMS type), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light points with 2 no. 2 way Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board (Make:Anchor) cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching colour) top cover 3 mm thick and incl. 175mm x 100mm x 62.5mm inspection box making earthing attachment, painting the MS box andmending good the damages to original finishAverage run 10 mtr |
| 73 | Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) |
| 74 | 19 mm dia 3 mm thick polythene pipe |
| 75 | 25 mm dia 3 mm thick polythene pipe |
| 76 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works |
| 77 | Channel Size : 40 mm x 40 mm19 mm dia 3 mm thick polythene pipe without earthcontinuity wire |
| 78 | Channel Size : 43 mm x 43 mm25 mm dia 3 mm thick polythene pipe without earthcontinuity wire |
| 79 | Supply & Fixing 240 V, 2 nos. 6A, plug socket with separate 2 nos. 6 A Piano key type switch, (Make:Anchor) (Black or white as directed by EIC)on sheet metal switch board embedded in wall incl. S & F 175x100x65mm MS (16SWG) switch board and Bakelite/Perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting Bakelite/Perspex cover and making necessary connections as required |
| 80 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Make:Anchor)(Black or white as directed by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/Perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/Perspex cover and making necessary connections as required |
| 81 | Supply & Fixing 240 V, 2 nos. 20A plug socket with separate 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Legrand/L&K/Approved make) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board (Make:Anchor) and bakelite/Perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/Perspex cover and making necessary connections as required |
| 82 | Supply and Fixing 240V, 1 no of 20A Piano key type switch and 1 no of 6A Piano key switch with separate 20A Plug socket and 6A Plug socket (Make:Anchor) on sheet metal switch board embedded in wall incl. S&F 200x150x65mm MS(16SWG) switch board and Bakelite/Perspex top cover of 3mm thick by brass screw after making housing for switch by cutting Bakelite/Perspex cover and making necessary connections as required. |
| 83 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch(Black or white as directed by EIC), indicator & 20A switch type SP MCB (Legrand/L&K/Approved make) on sheet metal switch board (Make:Anchor) embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/Perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/Perspex cover and making necessary connections as required |
| 84 | Supply & Fixing Socket type fan regulator (Step type) (Make:Anchor) on existing sheet metal switch board with bakelite/Perspex top cover by screw after making housing for regulator knob by cutting bakelite/Perspex top cover incl. making necy. connections etc. |
| 85 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 86 | 100 mm x 100 mm x 65 mm |
| 87 | 150 mm x 100 mm x 65 mm |
| 88 | 175 mm x 100 mm x 65 mm |
| 89 | 200 mm x 150 mm x 65 mm |
| 90 | 240 mm x 200 mm x 65 mm |
| 91 | Supply & Fixing bakelite / Perspex top cover on existing Inspection board by Brass screws |
| 92 | 100 mm x 100 mm x 65 mm |
| 93 | 150 mm x 100 mm x 65 mm |
| 94 | 175 mm x 100 mm x 65 mm |
| 95 | 200 mm x 150 mm x 65 mm |
| 96 | 240 mm x 200 mm x 65 mm |
| 97 | Supply & Fixing 240 V, 6 A Piano key type switch on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board (Make:Anchor) and bakelite/Perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/Perspex cover and making necessary connections as required |
| 98 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:Legrand/Schneider/Approved make), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 99 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make:Legrand/Schneider/Approved make) & necy. Connections. |
| 100 | Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Brand approved by EIC) without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.Make -Legrand Myrius (colour-Black/Dark brown or white) / Schneider / Approved make, as per instruction of EIC) |
| 101 | Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve)(Legrand/L&K/Approved make) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.Make -Legrand Myrius (colour-Black/Dark Brown or white / Schneider / Approved make, as per instruction of EIC) |
| 102 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Make:Legrand/Schneider/Approved make) with 25A Modular switch type DP MCB (C-Curve)(Legrand/L&K/Approved make) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 103 | Supply & Fixing 240 V, 25 A, Modular type starter (Make:Legrand/Schneider/Approved make) with 25A Modular switch type DP MCB (C-Curve) (Legrand/L&K/Approved make) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 104 | Supply & Fixing 240 V Modular type switch/socket (Make:Legrand/Schneider/Approved make) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 105 | 16 A Modular type switch(Make:Legrand/Schneider/Approved make) |
| 106 | 16 A, 3 pin Modular type plugsocket (Make:Legrand/Schneider/Approved make), without plug top |
| 107 | Supplying & Fixing GI Modular Switch Board (Make:Legrand/Schneider/Approved make) of 2 Module complete with top cover plate on wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 108 | Supply and Delivery of 4 feet Industrial box type single LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 109 | Supply and Delivery of 4 feet Industrial box type twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 110 | Supply and fixing of 240 V , 50Hz Recessed Mounted LED Luminaries having luminous flux not less than 3000 lumens (efficacy -100lm/W or more), CCT of 6500k, 50,000 LED burning hours or more ,ingress protection of IP20 , CRI>80 incl all accessories(like GI wire ,hooks etc for proper support) and necy connection by 3x1.5 sqmm PVC insulated Cu Wires required.[Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 111 | Supply and fixing of 240 V , 50Hz Recessed Mounted LED Luminaries having luminous flux not less than 1500 lumens( efficacy -100lm/W or more), CCT of 6500k , 50,000 LED burning hours or more, ingress protection of IP20 , CRI>80 incl all accessories( like GI wire ,hooks etc for proper support ) and necy connection by 3x1.5 sqmm PVC insulated Cu Wires required.[Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 112 | Supply and fixing 28 W LED Strip light( for 5 m) with driver having lumen 2150 colour temperature warm white with all other accessories directly on wall/false ceiling as per instruction of EIC(ref LED Strip SKY Cove 5M WW with driver Philips )[Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 113 | Fixing only single/twin LED light fitting complete with all accessories directly on wall/ceiling with MS \\"Z\\" Clamps and suitable size MS fastener, etc. as required |
| 114 | Fixing only single/twin LED light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 115 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 116 | Supply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories. (Make- Crompton / Usha / Orient) [BEE star rated]Sweep Size- 1200 mm (48\\"), Wattage ≤ 55 Watt, R.PM ≤ 380, Air Delivery ≥ 210 C.M.M |
| 117 | Supply & Delivery of 230V, 50Hz, 450 mm sweep heavy duty full metal body wall bracket fan having wattage ≤ 90 Watt, RPM ≤ 1350, Air Displacement (In CMM) ≥ 100 complete with all accessories. (Make - Orient/Crompton/ EPC) [BEE star rated] |
| 118 | Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [ISI mark, IP55 rated]225 mm (9\\"), 4 Blade, RPM ≤ 1400 , Wattage ≤ 45 Watt, Sound level ≤ 49 dB, Air Displacement (In CMH) ≥ 440 |
| 119 | Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [ISI mark, IP55 rated]300 mm (12\\"), 4 Blade, RPM ≤ 1420 , Wattage ≤ 90 Watt, Sound level ≤ 56 dB, Air Displacement (In CMH) ≥ 1120 |
| 120 | Supply & Delivery of following 230V, 1-Ph, Pedestal Air Circulators with all accessories. 450 mm Sweep, 1-Ph, 3 Blade, RPM ≤ 1440 , Wattage ≤ 100 Watt, Air Displacement (In CMH) ≥ 5000 Pedestal (Make- Crompton / Usha / Orient/EPC) [BEE star rated] |
| 121 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F safety wire , connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 122 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. |
| 123 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) |
| 124 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80mmdepth made of 16 SWG CRCA sheet with one end duly sealed bycover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. |
| 125 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 126 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 127 | 23 cm Exhaust fan (9\\") |
| 128 | 30 cm Exhaust fan (12\\") |
| 129 | Supply & Fixing Al louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 130 | 23 cm Exhaust fan (9\\") |
| 131 | 30 cm Exhaust fan (12\\") |
| 132 | Supplying & fixing medium gauge of the following dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing materials asrequired |
| 133 | 25 mm |
| 134 | 40 mm |
| 135 | Cost of Dismantling of all the electrical equipment's like fans, tube lights, power sockets ,distribution boards ,panels etc with one's own tools' and tackle and shifting them properly from site to designated store as per direction of EIC incl mending good damages to original finish |
| 136 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe |
| 137 | Excavation of soil for installation of Earth Electrode and filling & ramming (For Soft soil) |
| 138 | Extra for providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 139 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 140 | Connecting the equipment to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipment with bolts, nuts, washers, cable lugs etc. as required and mending good damagesNo. 6 SWG |
| 141 | Connecting the equipment body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipment incl. drilling holes, with bolts, nuts, washers etc. |
| 142 | Dismantling charge for existing split/window type air conditioner and handing it over to the store house /section office as per instruction of EIC |
| 143 | Supply of 1.1 Tr. Capacity Rated Split type Air - Conditioner Machine having cooling capacity 4000 watt ,Rated Power input 1020 watts,ISEER 3.92,Rated Current 4.5-5.5 Amps. Supply of 230 Volt AC 50 Hz.Compressor type- Rotary, Refrigerant type -R 32,Coil Material -Copper and features like modes (Auto,cool,fan,dry ) air flow 1100 m3/hr ( horizontal louver/vertical swing) sleep mode timer off/dust air filter [Make: O-General / Mitsubishi Heavy Duty / Mitsubishi Electric / Daikin] with star rating 3 (Minimum). |
| 144 | Supply of 1.5 Tr. Capacity Rated Split type Air - Conditioner Machine having cooling capacity 5300 watt ,Rated Power input 1380 watts,ISEER 3.84,Rated Current 6.0-7.0 Amps. Supply of 230 Volt AC 50 Hz.Compressor type- Rotary, Refrigerant type -R 32,Coil Material -Copper and features like modes (Auto, cool,fan,dry ) air flow 1400 m3/hr ( horizontal louver/vertical swing) sleep mode timer off/dust air filter [Make: O-General / Mitsubishi Heavy Duty / Mitsubishi Electric / Daikin] with star rating 3 (Minimum). |
| 145 | Supply of 2.0 Tr. Capacity Rated Split type Air - Conditioner Machine having cooling capacity 7050 watt ,Rated Power input 1850 watts,ISEER 3.92,Rated Current 8.0-9.0 Amps. Supply of 230 Volt AC 50 Hz.Compressor type- Rotary, Refrigerant type -R 32,Coil Material -Copper and features like modes (Auto, cool,fan,dry ) air flow 1450 m3/hr ( horizontal louver/vertical swing) sleep mode timer off / dust air filter [Make: O-General / Mitsubishi Heavy Duty / Mitsubishi Electric / Daikin] with star rating 3 (Minimum). |
| 146 | Supply of 1.5 Tr. Capacity Rated Window type Air - Conditioner Machine cooling capacity 5300 watt ,Rated Power input 1700 watts,ISEER 3.12,Rated Current 6.0-8.0 Amps. Supply of 230 Volt AC 50 Hz.Split type Air - Conditioner Machine having features modes (Auto, cool,fan,dry ) air flow-950 m3/h ( horizontal louver/vertical swing) sleep mode timer off/on anti freeze thermostat bio/active carbon/dust air filter[Make: O-General / Mitsubishi Heavy Duty / Mitsubishi Electric / Daikin] with star rating 3 (Minimum). |
| 147 | Installation, testing and commissioning of 1.1/1.5/2.0 TR Capacity R410A/R32 Ref Gas split air conditioner with iron bracket (powder coated) including initial charging of cooling agent R410A/R32 gas and all necessary fittings and fixtures ,angle support etc. as required by site condition |
| 148 | Installation, testing and commissioning of 1.5 Tr window AC including wood frame of required size and GI tray with proper fixing arrangement , initial gas charging and mending good the damages to original finish. |
| 149 | Supply and Fixing of Copper Refrigeration pipe line (Make:Nippon/Ryoku/Rajko) for both Liquid line and Suction Line suitable for the above split unit with hard /soft drawn copper piping and with proper supports & brackets( per direction of E.I.C.) incl. 9 mm thick nitrile rubber insulation with proper tapping and mending good damages to original finish. |
| 150 | Suction Line : 5/8\\" Dia |
| 151 | Suction Line : 1/2\\" Dia |
| 152 | Liquid Line : 1/4\\" Dia |
| 153 | Supply & drawing 3 core 2.5 sq. mm. P.V.C. insulated wire for connecting the Power hub to Outdoor unit supply. [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] |
| 154 | Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated wire for connecting the outdoor to indoor supply.[Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] |
| 155 | Supply & laying of 3/4 '' PVC flexible drain pipe (Supreme / Oriplast /Approved make ) with necessary accessories as required. |
| 156 | S&F of 25 mm heavy type (40 Grade) UPVC pipe with necessary elbows,connector,solvent cement & clamps. (Make: Supreme / Oriplast / Approved make) |
| 157 | Supplying, fabrication incl painting & fixing of frame for keeping the outdoor of AC machines with M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame/platform for installation of outdoor unit of above mentioned AC machines incl. drilling 2 no's holes in each channel , cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with . horizontal flats of 25 mm x 5 mm and supporting angle of 50mm x50mm x 6mm in each platform in the outer edge for transmitting the load centrally through 3 no's (50 mm x50mm x6 mm) angle inserted into the existing wall incl. construction of railing with 25 mmx25mmx6mm and 25 x5 mm flats as per Direction of E.I.C. The entire structure must be safe to carry out maintenance of ODU . Area of the platform is 3.5 Mtr. x 1.4 Mtr., as per Direction of E.I.C |
| 158 | Supply, Fabrication & Installation of Enclosed safety cage with lock & key arrangements for AC machines outdoor at Ground Floor. :- Size of MS structure frame as given : 1.4mtr.(L) x 0.8mtr.(D) [Extra depth = 0.15 mtr. for fixing in wall] x 1.0mtr.(H). with MS equal angle and MS Flat. Numbers & Sizes of MS equal angles are - 1) 35x35x5mmx0.95mtr =4 nos. 2) 25x25x5mmx1.0mtr = 6 nos. & 3) 25x25x5mmx1.4mtr.= 6 no's. and Number & Sizes of MS Flats are - 1) 25x5mmx1.4mtr = 9 no's 2) 25x5mmx1.0mtr.= 10 no's & 3) 25x5mmx0.8mtr.= 14 nos. are to be used for making the structure which will be fixed on the outside of concrete wall by cutting hole & necessary scaffolding arrangement & mending good damages as per direction of EIC. Total weight of enclosed safety cage is approx. 70 kg. The structure is to incorporate lock & key facility with hinge arrangement at front opening required for necessary servicing, including necessary painting with one coat RO primer & 02 coat of Oil paint( Asian paint/ Shalimar/ Berger). |
| 159 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for ODU and Structure installation, per storey of building per vertical run |
| 160 | Supply & Delivary of Professional Digital Laser Measure (Blue) Meter Range 40 Mtr & -20 to +60 °C/ Resolution 0.1 m/s & 0.1 °C / Battery Life 130 Hrs/ Dimensions 10.5L x 4.1W x 2.4H Centimeters/ Warrenty 2 Yrs. LCD Display for Distance Measurement incl Battery as per GS. (Make -Bosch GLM 40 / Similar Specification of Testo/ Similar Specification of FLUKE/FLIR) as per direction by EIC. |
| 161 | Supply & Delivary of Fluke 302+ Digital Clamp Meter, Multi, Standard AC/DC Current Frequency Measurement Voltage Handheld Ohm Tester Wide Voltage Range Accurate LCD Display/ Dimensions 18 x 12 x 8 cm; 300 g for Electrical parameter Measurement incl Battery as per GS. (Make - FLUKE/ Similar Specification of Taparia / Similar Specification of Meco/Metravi/BOSCH/AE ) as per direction by EIC. |
| 162 | Supply & Delivery of Digital Earth tester Meter able to measure Both Earth Resistance and Earth Resistivity can be measured. Can be used in 4 Terminal and 3 Terminal configurations & Should contain the following specification Earth Resistance Range : 0 - 10/100/1000 Ohms Accuracy : ±2%. Low Resistance Range : 0 - 200 k.Ohms Accuracy : ±2%. DC Voltage : 0 - 1000V Accuracy : ±0.8%. AC Voltage : 0 - 750V Accuracy : ±1.2% (Make- Metravi/Taparia/Testo/Bosch) |
| 163 | Less cost for the dismantled materials - Rs. 3,000.00 |
| 164 | The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules |
| 165 | Defect Liability Period - 1 One) year after completion of work |
| 166 | Make & model of each and every material to be approved by EIC Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail