| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Havells/Finolex/RR Kabel/Gloster/Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. |
| 2 | Average run 11 mtr [E-24/1(f)] |
| 3 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Havells/Finolex/RR Kabel/Gloster/Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works |
| 4 | On Board [E-24/3(a)] |
| 5 | Average run 4.5 mtr [E-24/3(d)] |
| 6 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [E-16/7] |
| 7 | 20 mm size [ 7(a)/ E- 16 ] |
| 8 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. |
| 9 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC [ E-9/1(s)] |
| 10 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)] |
| 11 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc.,including supplying sockets, tapes. |
| 12 | 1.5 sq mm |
| 13 | 2.5 sq mm [9(i) / F-5] |
| 14 | 4 sq mm [9(ii) / F-5] |
| 15 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [12/ E-18] |
| 16 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 9(b) / E-18 ] |
| 17 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. [E-17/1] |
| 18 | 6 module [1(b)/E-17] |
| 19 | Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. [E-17/3(a)] |
| 20 | Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)] |
| 21 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket(Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)] |
| 22 | Supply & Fixing 240 V, 6/16 A, 5 pin Modular type plug socket(Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)] |
| 23 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 24 | 175 mm x 100 mm x 65 mm [E-4/11(c)] |
| 25 | 200 mm x 150 mm x 65 mm [E-4/11(d)] |
| 26 | Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws |
| 27 | 175 mm x 100 mm x 65 mm [E-5/13(c)] |
| 28 | 200 mm x 150 mm x 65 mm [E-5/13(d)] |
| 29 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket(Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/E-17] |
| 30 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) & necy. Connections [5(b)/E-17] |
| 31 | Fixing only cabin/wall fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20PVC insulated flexible copper wire 0.5 mt. length as per GS [ 29/C-4 ] |
| 32 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter |
| 33 | 23 cm (9\\") [28(a)/C-4] |
| 34 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. (D-13/20(a)) |
| 35 | Supply & fixing of Blank plate for modular board. (mk-Legrand / Roma/ Siemens) |
| 36 | Supply & Delivery of 35/36 Watt Indoor type 2'x2' Full glow recessed mounting LED light fitting complete with all accessories [Make- Philips RC380B LED42S 6500 G6 L60W60 PSU OD S1/ Wipro CRCO1ORO3OHP57G3] |
| 37 | Supply & delivery of Full metal body & blade wall bracket fan 18inch (1420 RPM) (make -EPC/Crompton 450mm ACVORTEX 18 WM) |
| 38 | Fixing only Ceiling light fitting on wall /ceiling by screws etc. [ 13/C-2 ] |
| 39 | Supply and delivery of 11W Indoor type LED Mirror light fitting. (Make-Philips 31165/ Wipro Eqv as approved by E.I.C) |
| 40 | Fixing only Mirror light fitting complete with all accessories directly on wall/ceiling by screws etc. [ 14 (a)/C-2 ] |
| 41 | Supply & fixing of 250mm PVC Body Exhaust Fan. ( Make:- Crompton Brisk Air Neo or Eqv Model of Havells/Orient as per choice of EIC) |
| 42 | Supply & fixing automatic single phase AC starter of 21 Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of L&T/Legrand as per dierction of E.I.C) to be fixed on 4Module GI box with all fixing accessories complete as to G.S. |
| 43 | Supply & Fixing LED Engage Board (Brand Approved by EIC) (1'X1/2') as directed by EIC. |
| 44 | Supply & Fixing LED Entry Board (Brand Approved by EIC) (1'X1/2') as directed by EIC. |
| 45 | Supply & Fixing LED Exit Board (Brand Approved by EIC) (1'X1/2') as directed by EIC. |
| 46 | S&F of LED 5 Meter long Strip Light with all accessories and required fixing materials (Make:- Philips, Cat No- LED Strip SKYCove 5M WW with driver or Equivalent Model of Crompton) as per direction of EIC. |
| 47 | Disconnection & dismantling existing old Electrical installation, Switch-board, wiring, Electrical fitting/fixtures etc along with existing AC Machines IDU with owns tools & takles incl. mending good damages and clearing/removing from the site and diposite the same to the authority as directed by EIC. |
| 48 | Supply & filling/poring rerigerant R410/R32 refrigerant gas for AC machines incl. testing and commissioning of complete machines with all indoors, outdoor units, electrical, remotes incl. pressure testing with nitrogen and vaccumiazation |
| 49 | Re-installation, testing & commissioning of the split ACs on wall with appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. |
| 50 | SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleevessections of specified thickness as given below for suction andliquid lines, all accessories as per specification etc. as required. |
| 51 | 5/8\\" (15.88 mm.) (for suction) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC) |
| 52 | 1/4\\" (6.4 mm) ( for discharge) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC) |
| 53 | Supply & Laying of 4 core 1.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between lndoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.l.C) |
| 54 | Supply & Laying of 3 core 2.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.I.C) |
| 55 | Supply and laying 25 mm PVC pipe (heavy type) for water drainage.(25mmOD, 1mm thick) with proper support & bracket as per direction. (Make- Supreme/Oriplast). |
| 56 | Add GST @ 18% on sl. No. 1 to 20 |
| 57 | Add LWC @ 1% on sl. No. 1 to 21 Please Enable Macros to View BoQ information |