| 1 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.[ F-2/1(b)] |
| 2 | Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench forsingle, 2, 3, 3½ and 4 core [F-1/3(b)] |
| 3 | Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(e)] |
| 4 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. [F-3/5(iii] |
| 5 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 6 | 4 Core 95 Sq. mm [F-4/7(c)] |
| 7 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.[F-5/8(b)] |
| 8 | 4 Core 95 Sq. mm |
| 9 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials. [F-6/11] |
| 10 | 50 mm dia |
| 11 | Supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts,bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[D-4/4(b)]250A ( Make L&T/ Siemens/ ABB (E)) |
| 12 | Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make: Polycab/Gloster/Finolex/Havells/RR Kabel] |
| 13 | 4 Core 95 Al cable [ Sub Station to Panel] |
| 14 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 15 | (i) Pakur Variety [PWD Civil S.O.R 2017 Building Page 26 Item No- 10] |
| 16 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand [PWD Civil S.O.R 2017 Building Page no 14 Item No- 1] |
| 17 | Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD By Manual Means.a) Bituminous Courses.[ PWD Road S.O.R 2018 Item No- 2.14 page no 235] |
| 18 | Add. G.S.T.@ 18% on total of item |
| 19 | Add. LWC.@ 1% on total of item Please Enable Macros to View BoQ information |