| 1 | Supply Installation, Testing and Commissioning of ST Pole as per approved standard/drawing |
| 2 | 13 mtr long ST Pole (ST-410 SP69) |
| 3 | 11 mtr long ST Pole (ST-410 SP56) |
| 4 | 09 mtr long ST Pole (ST-410 SP33) |
| 5 | Erection of ST Poles including loading at stores, transit insurance, carriage and unloading at site as per approved specifications and drawings |
| 6 | 13 mtr long ST Pole (ST-410 SP69) |
| 7 | 11 mtr long ST Pole (ST-410 SP56) |
| 8 | 09 mtr long ST Pole (ST-410 SP33) |
| 9 | Dismantling of ST Pole with allied accessories including loading at site, transit insurance, carriage and unloading at store |
| 10 | 13 mtr long ST Pole (ST-410 SP69) |
| 11 | 11 mtr long ST Pole (ST-410 SP56) |
| 12 | 09 mtr long ST Pole (ST-410 SP33) |
| 13 | Wooden Poles of different sizes |
| 14 | Straightening of existing tilted poles including Cement Bottoming as per approved standard/drawing |
| 15 | 13 mtr long ST Pole (ST-410 SP69) |
| 16 | 11 mtr long ST Pole (ST-410 SP56) |
| 17 | 09 mtr long ST Pole (ST-410 SP33) |
| 18 | Providing and Painting of ST Poles including fixtures with one coat of Red-oxide and two coats of Aluminium (silver colour) paint to give even shade as per approved standard/drawing |
| 19 | 13 mtr long ST Pole (ST-410 SP69) |
| 20 | 11 mtr long ST Pole (ST-410 SP56) |
| 21 | 09 mtr long ST Pole (ST-410 SP33) |
| 22 | Providing and Laying of Cement Bottoming of ST Poles in 1:2:4 mix using 20 mm crush stone aggregate including shuttering etc. complete as per approved Standard/Drawing |
| 23 | 13 mtr long ST Pole (0.78 cum/pole) |
| 24 | 11 mtr long ST Pole (0.66 cum/pole) |
| 25 | 09 mtr long ST Pole (0.48 cum/pole) |
| 26 | Providing and fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip (25x3)mm 4 Mtr long as per approved standard/drawing |
| 27 | Providing and fixing of Spike Earthing Rod 20mm 2.5 Mtr long with GI strip (25x3)mm as per approved standard/drawing |
| 28 | Providing and fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 ) mm, nutbolts, 2 Nos turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete as per approved standard/drawing |
| 29 | Providing and fixing heavy duty aluminium alloy PG clamps / Pad clamps / T-clamps suitable for ACSR conductor, complete with galvanised hardware, conforming to relevant IS specifications and approved drawings for |
| 30 | 0.2 ACSR Conductor 4-bolt type |
| 31 | 0.15 ACSR Conductor 4-bolt type |
| 32 | 0.1 ACSR Conductor 3-bolt type |
| 33 | Fixing (including loading at stores, carriage and unloading at site) of P.G Clamps /Pad Clamps/ T-Clamps as per relevant specifications and approved drawings suitable for |
| 34 | 0.2 ACSR Conductor |
| 35 | 0.15 ACSR Conductor |
| 36 | 0.1 ACSR Conductor |
| 37 | Supply,Laying,stringing ,tensioning and binding of ACSR Conductor as per approved specifications and drawings |
| 38 | 0.2 ACSR Conductor |
| 39 | 0.15 ACSR Conductor |
| 40 | 0.1 ACSR Conductor |
| 41 | Laying,stringing ,tensioning and binding of ACSR Conductor including loading at stores, transit insurance, carriage and unloading at site as per approved specifications and drawings |
| 42 | 0.2 ACSR Conductor |
| 43 | 0.15 ACSR Conductor |
| 44 | 0.1 ACSR Conductor |
| 45 | Re-stringing of loose conductor including tensioning, binding etc as per relevant specifications and approved drawings |
| 46 | 0.2 ACSR Conductor |
| 47 | 0.15 ACSR Conductor |
| 48 | 0.1 ACSR Conductor |
| 49 | Supply, and Fixing of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant specifications and approved drawings |
| 50 | Fixing (including loading at stores, carriage and unloading at site) of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant specifications and approved drawings |
| 51 | Supply and Fixing of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting as per relevant specifications and approved drawings |
| 52 | Fixing (including loading at stores, carriage and unloading at site) of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting as per relevant specifications and approved drawings |
| 53 | Supply and Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per relevant specifications and approved drawings |
| 54 | Fixing (including loading at stores, carriage and unloading at site) of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per relevant specifications and approved drawings |
| 55 | Supply and Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting as per relevant specifications and approved drawings |
| 56 | Fixing (including loading at stores, carriage and unloading at site) of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting as per relevant specifications and approved drawings |
| 57 | Providing and fixing of suspension/ tension fitting as per approved specifications/standard of |
| 58 | Tension fitting 33kV line 6 Bolt/ Suspension Fitting 3 Bolt |
| 59 | 11kV line 4 Bolt/ Suspension Fitting 2 Bolt |
| 60 | Fixing (including loading at stores, carriage and unloading at site) of suspension/ tension fitting |
| 61 | Tension fitting 33kV line 6 Bolt/ Suspension Fitting 3 Bolt |
| 62 | 11kV line 4 Bolt/ Suspension Fitting 2 Bolt |
| 63 | Providing and fixing of danger plates with clamps as per relevant specifications and approved drawings |
| 64 | Providing and fixing of anti climbing devices with clamps as per relevant specifications and approved drawings |
| 65 | Providing and fixing of fabricated GI Channel / Angle of sorts as per site requirement as per relevant specifications and approved drawings |
| 66 | Fixing (including loading at stores, carriage and unloading at site) of fabricated GI Channel / Angle of sorts as per site requirement as per relevant specifications and approved drawings |
| 67 | Extensive Branch cutting of trees coming in the coridor 33KV line including cutting of trees beneath the 33KV line (complete job) |
| 68 | Supply,erection,testing and commissioning of 33KV, Single core Aluminium, round wire Armoured XLPE Cable , FRLS One spare cable to be placed underground 3fts using HDPE Pipes as per relevant specifications and approved drawings |
| 69 | 120 sqmm |
| 70 | 185sqmm |
| 71 | 240sqmm |
| 72 | 300sqmm |
| 73 | 400sqmm |
| 74 | 630sqmm |
| 75 | Erection (including loading at stores, carriage and unloading at site),testing and commissioning of 33KV, Single core Aluminium, round wire armoured XLPE Cable , FRLS One spare cable to be placed underground 3fts using HDPE Pipes as per relevant specifications and approved drawings |
| 76 | 120 sqmm |
| 77 | 185sqmm |
| 78 | 240sqmm |
| 79 | 300sqmm |
| 80 | 400sqmm |
| 81 | 630sqmm |
| 82 | Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size as per relevant specifications and approved drawings |
| 83 | 120 sqmm |
| 84 | 185sqmm |
| 85 | 240sqmm |
| 86 | 300sqmm |
| 87 | 400sqmm |
| 88 | 630sqmm |
| 89 | Fixing (including loading at stores, carriage and unloading at site) of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size as per relevant specifications and approved drawings |
| 90 | 120 sqmm |
| 91 | 185sqmm |
| 92 | 240sqmm |
| 93 | 300sqmm |
| 94 | 400sqmm |
| 95 | 630sqmm |
| 96 | Providng and fixing of guard netting of existing 33KV line using 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts and angle Iron arms where ever required complete Job for span of 58 meter as per relevant specifications and approved drawings |
| 97 | Supply,installation,testing and commissioning of 33kV Isolator with Earthing Blade (36kV,800A,Outdoor,3 poles,25kA) as per relevant specifications and approved drawings |
| 98 | Fixing (including loading at stores, carriage and unloading at site),installation,testing and commissioning of 33KV isolators with earthing blade as per relevant specifications and approved drawings |
| 99 | Supply,installation,testing and commissioning of 33kV Isolator without Earthing Blade (36kV,800A,Outdoor,3 poles,25kA) |
| 100 | Fixing (including loading at stores, carriage and unloading at site),installation,testing and commissioning of 33KV isolators without earthing blade as per relevant specifications and approved drawings |
| 101 | Providing of portable and extension aluminium telescopic ledder 18' long. Anodiozed Siliver Anti, slip steps |
| 102 | Providing two fold Alumunium Ladder 2*20 ' , 3 mm Thick (extendable with rope and pully arrangement) |
| 103 | Providing of Safety Shoes (Ankle Boot) |
| 104 | Providing of Safety Helmet |
| 105 | Providing of Rubber Gloves 33kV level |
| 106 | Providing of Safety Belt ISI Mark |
| 107 | Providing of Earthing rod 5 mtr long with 25 mm sq cable 12 mtr for one phase |
| 108 | Providing of HV Detectors all voltages upto 33kV |
| 109 | Providing of Manila Rope |
| 110 | Providing of P.P Rope Please Enable Macros to View BoQ information |