| 1 | Detail of Work |
| 2 | Safely carriage of 11 KV I/C VCB (CTR 600/300/5A) from ESC, SRE to site of work including loading & unloading at both ends. |
| 3 | Safely carriage of 11 KV O/G VCB (CTR 200/1005A). from ESC, SRE to site of work including loading & unloading at both ends. |
| 4 | Safely carriage of 33 KV VCB (1250A). from ESC, SRE to site of work including loading & unloading at both ends. |
| 5 | Safely Installation of 11 KV I/C VCB (CTR 600/300/5A) complete with fixing and making cable connection with proper alignment in all respect. |
| 6 | Safely Installation of 11 KV O/G VCB (CTR 200/1005A).complete with fixing and making cable connection with proper alignment in all respect. |
| 7 | Safely Installation of 33 KV VCB (1250A) complete with fixing and making cable connection with proper alignment in all respect. |
| 8 | Removal of old & damaged 11 KV VCB after opening of all connection and nuts & bolts with carriage from site to ESC SRE including loading & unloading at both ends. |
| 9 | Water Level Earthing of 11 KV Incoming /Outgoing VCB by boring 60 ft. deep and providing & fixing 60 ft. G.I. pipe 1½ dia (Jindal class B) and connecting with G.I. strip of size 40x5 mm with providing of requireed charcoal and salt in the pipe properly. |
| 10 | Making of New Structure for 33 KV VCB. |
| 11 | Safely carriage of 33 KV New Contral panel Double T/F from ESC, SRE to site of work including loading & unloading at both ends.. |
| 12 | Safely Installation of 33 KV New Contral panel Double T/F complete with fixing and making cable connection with proper alignment in all respect. |
| 13 | Supply, & laying, testing & commissioning of 4 x 2.5 & 2x2.5 sq.mm Copper conductor, PVC insulated, PVC sheathed, armoured control cable of 1.1 kV grade conforming to IS complete with glands, lugs and all accessories. |
| 14 | Safely carriage of 33 KV Line Isolator (800A) from ESC, SRE to site of work including loading & unloading at both ends. |
| 15 | Making of New Structure for 33 KV Line Isolator (800A) |
| 16 | Safely installation 33 KV Line Isolator (800A) complete with fixing and making cable connection with proper alignment in all respect. |
| 17 | Removal of old & damaged 33 KV Line Isolator after opening of all connection and nuts & bolts with carriage from site to ESC SRE including loading & unloading at both ends. |
| 18 | Water Level Earthing of Power T/F by boring 60 ft. deep and providing & fixing 60 ft. G.I. pipe 1½ dia (Jindal class B) and connecting with G.I. strip of size 40x5 mm with providing of requireed charcoal and salt in the pipe properly. |
| 19 | Safely carriage of 33 KV Fuse Set from ESC, SRE to site of work including loading & unloading at both ends. |
| 20 | Making of New Structure for 33 KV Fuse Set |
| 21 | Safely installation 33 KV Fuse Set complete with fixing and making cable connection with proper alignment in all respect. |
| 22 | Safely carriage of Battery set 24 Volt 200 Ah. (16 No) and battery charger 24 volt (16 No) from ESC, SRE to site of work including loading & unloading at both ends. |
| 23 | Installation of Battery set 24 Volt 200 Ah. (16 No) and battery charger 24 volt (16 No) complete with fixing and making cable connection with proper alignment in all respect. |
| 24 | Safely carriage of 33 KV CT, 200/100/1-1-1A from ESC SRE to site of work including loading & unloading at both ends. |
| 25 | Installation of 33 KV CT, 200/100/1-1-1A complete with fixing and cable connection with proper alighment in all respect. |
| 26 | Safely carriage of 33 KV (Outdoor) PT/110V from ESC SRE to site of work including loading & unloading at both ends. |
| 27 | Installation of 33 KV (Outdoor) PT/110V complete with fixing and cable connection with proper alighment in all respect. |
| 28 | Providing & Installation of O.T.I (36 No) & W.T.I (36 No) on transformer and making connection & setting properly. |
| 29 | Safely carriage of 33 KV lightening arrestor (L.A.) from ESC SRE to site of work including loading & unloading at both ends. |
| 30 | Installation of 33 KV lightening arrestor (L.A.) complete with of earthing with proper alighment in all respect. |
| 31 | Purchasing & Instalattion Ashida Numerical OC/EF Protection Relay ADR 241A. |
| 32 | Removal of old & damaged Battery set/charger (16 No) , 33 KV PT/CT (110 No) , WTI/OTI (25 No) L.A. (60 No) after opening of all connection and nuts & bolts with carriage from site to ESC SRE including 3loading & unloading at both ends. Please Enable Macros to View BoQ information |