| 1 | PART-A |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils ( As per PWD BSR chap-B-1,Item no 1.8) |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) ( As per PWD BSR chap-B-3,Item no 3.1,3.1.4) |
| 4 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 gradedstone aggregate 20 mm nominal size) upto plinth level with Cement Mortar 1:6( 1-Cement : 6-Sand).(chap-E23 Item no 23.22) |
| 5 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) ( As per PWD BSR chap-B-5,Item no 5.2,5.2.2) |
| 6 | Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .50mm thick. ( As per PWD BSR chap-B-3,Item no 3.7,3.7.1) |
| 7 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. ( As per PWD BSR chap-B-4,Item no 4.10,4.10.2) |
| 8 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Hot rolled deformed bars (IS : 1139). ( As per PWD BSR chap-B-4,Item no 4.13,4.13.2) |
| 9 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix ( As per PWD BSR chap-B-4,Item no 4.1) |
| 10 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12 mm thick . ( As per PWD BSR chap-B-12,Item no 12.2,12.2.3 ) |
| 11 | Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 75mm dia. Pipes. ( As per PWD BSR chap-B-12,Item no 12.54,12.54.1 ) |
| 12 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint M.S. Sheet 22 SWG(.63 mm thick). ( As per PWD BSR chap-B-9,Item no 9.17 ) |
| 13 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. ( As per PWD BSR chap-B-4,Item no 4.9 ) |
| 14 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specificaion for electrical works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it's all accessories(J.B. , Bends etc.), round tiles,18 SWG G.I. Box with earth terminal,6 A switch, 3pin ceilng rose/lamp holder/ 3 point connector, 3.0 mm thick ISI marked phenolic laminaled sheet AI alloy/ cadmium plated iron srews 20 mm cup washers etc.all as per pre approved Engineer in charge making connections testing etc complete as required for specification of copper conductor , Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.As per PWD ELE SR 2022 Item |
| 15 | Short point (up to 3 mtr.) |
| 16 | Medium point (up to 6 mtr.) |
| 17 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances ofoxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR |
| 18 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 19 | 2 x 6.0 sq.mm |
| 20 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary supportsafety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Allas per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 21 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 22 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR. |
| 23 | 18/20 Watt |
| 24 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.1.00 mm thick with zinc coating not less than 275 gm/m2 (chap B-10 Item no10.1.1) |
| 25 | SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 -440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on xisting platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge pectively complete in all respect.OEM shall have submit ABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .( P.W.D. Rajasthan Electrical B.S.R. 2022 Chapter E-21 item no.21.7.1) |
| 26 | Poly propylene - Random - Co - polymer (PPR) pipes SDR 7.4 - 25mm Outer dia.( As per PWD BSR BASIC RATES OF MATERIALS,Item no 8627 ) |
| 27 | White sand stone slab 75 mm thick (un-dressed)( As per PWD BSR BASIC RATES OF MATERIALS,Item no 1163 ) |
| 28 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 450mm x 300 mm( As per PWD BSR chap-S-1,Item no 1.36.1) |
| 29 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) ( As per PWD BSR chap-B-9,Item no 9.19.3) |
| 30 | Supply & Fixing of Water + AFFF 6% Mechanical Foam type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 25 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Capacity - 6 Ltrs.(As per pwd electrical bsr ch-24, item no. 24.65.1) |
| 31 | Supplying and fixing of thermal insulation on exposed roof (underdeck) with 25 mm thick Cross Linked Closed Cell Polyethylene FR-XPE insulation of density 33 Kg/m³ with adhesive etc. as required & finally fixed with the help of rawl plug, dash fasteners & adhesive in ceiling of pieces in size of 900x900 mm or 1200x1200 mm. etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . (As per pwd electrical bsr ch-22, item no. 22.21) |
| 32 | PART-B Supply and Installation of Spice Processing Unit 35 Kg/HrDescription for supply and installation of machines and accessories |
| 33 | Tray Dryer : 6 Tray Dryer Machine Body MS +SS Capacity 40-50kg Per Hr Depend On Materials, Single Phase |
| 34 | Masala Roaster: 18x18 Masala Roaster and Mixing Machine Tilting Model Body SS Capacity 7-8 Kg Per Batch depend On Materials Gas +Electric Base 0.5 Hp, Single Phase |
| 35 | Kandap Machine: 2 Rod Kandap Machine with Motor Body MS +SS Capacity 8-10 Kg Per Hr Depend On Materials 2.0 Hp, Single Phase |
| 36 | Pulverizer: 3 Hp Blower Pulverizer Machine with Motor body MS Capacity 20-25 Kg Per Hr Depend On Materials, Single Phase |
| 37 | Vibro Sifter: Mini Powder Channa (Sieving) Machine With Motor Body M S Capacity 40-50 Kg Per Hr Depend OnMaterials 0.5 Single Phase |
| 38 | Automatic Weighing and Pouch Packing Machine LD: 1000 (Spice Powder Capacity 15gm To 500 gm) Automatic Weighing and Pouch Packing Machine (Maximum Open Roll Can Use 420 mm, Capacity depends On Material, Single Phase |
| 39 | Band Sealer: 3 Kg SS Band Sealer Machine Capacity 2-5 Pouch Per Second, Single Phase , with extra set of sealing bands. |
| 40 | Weighing machine range 0-100 Kg Digital 2*2 feet platform |
| 41 | Batch Coder: 4' Inch TIJ Batch Coder Machine For MRP, Expiry, and Date Print |
| 42 | Working Table Size 4*8 MOC: All Contact parts are in SS 304 and Mounted on MS Frame |
| 43 | Suprene Plastic Pallets Suprene injection moulded close dack single side legs colour : Blue Static :3000, Dyanamic :750 Weight 13.10Kg+/- 3 to 4% |
| 44 | Let Truck With Nylon Wheels Capacity :2.5 Ton |
| 45 | Control Panels , Cables & Switches set |
| 46 | AMC Charges for Three Years (Yearly Two Visits) LS |
| 47 | PART-3 Supply and installation of 10 KW Solar Power System |
| 48 | Solar Grid tied connected power plant (SPV) - Design & supply of solar panel, solar inverter, Cable & Net Meters, Structure, Bos of SPV System. 10 KW Please Enable Macros to View BoQ information |