| 1 | Civil Renovation works and out side painting to the Meghnad Saha Planetarium Golapbag -B.U. |
| 2 | Ordinary Cement concrete (mix 1:1.5:3) withgraded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes i) Ground Floor |
| 3 | Hire and labour charges for shuttering withcentering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works 25-30 mm thickapproved quality wooden plank shuttering in any concrete work i) Ground Floor |
| 4 | Reinforcement for reinforced concrete workin all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i) Tor steel/Mild Steel (i) Upto 4 th floor roof in each addl. floor a) Ground Floor |
| 5 | Brick work with 1st class bricks in cementmortar (1:6) (a) In foundation and plinth |
| 6 | In super structure |
| 7 | Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth |
| 8 | In superstructure, ground floor |
| 9 | 125 mm. thick brick work with 1st classbricks in cement mortar (1:4) in ground floor. A) Ground Floor |
| 10 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. |
| 11 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. |
| 12 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. upto 150 mm. thick |
| 13 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. |
| 14 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 15 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (i) With 1:6 cement mortar (b) 20 mm thick plaster a) Ground Floor |
| 16 | (iii) With 1:3 cement mortar(c) 10 mm thick plastera) Ground Floor |
| 17 | Applying Interior grade Acrylic Primer ofapproved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer |
| 18 | Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 19 | Priming one coat on steel or other metalsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 20 | Painting with best quality syntheticenamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :With super gloss (hi-gloss) Two coats (with any shade except white) On timber or plastered surface : |
| 21 | On steel or metal surface : |
| 22 | wood work in door and window frame fitted and fixed in position all complete sal local |
| 23 | Removing old scale ,blisters etc of interior surface of walls ceiling by scraping etc and preparation surface with rendering or cement morter(1:2) as necessary. |
| 24 | Labour for taking out door and window frame with or without horns and including shutter for repair replacement of different parts of the frame and refixing the same including mending good all damaes complete |
| 25 | Iron butt hinges of approved quality with ISI mark . (100mm x58mm x1.9mm) |
| 26 | Iron socket bolt of approved quality fitted and fixed complete. 150 mm long x 10mm dia bolt. |
| 27 | Iron hasp bolt of approved quality fitted & fixed complete . 250mm long |
| 28 | Supplying Godrej mortice lock c.p.with latch and key 4 levers incl fitting and fixing complete |
| 29 | Hydralic door closer of approved quality as per I.S.I. Standard fitted and fixed complete.Medium (ISI size -2) |
| 30 | Iron door ring of approved quality 50mm dia fitted & fixed complete . |
| 31 | Anodised aluminium D-type handle of approved quality 150 mm grip x10 mm dia rod |
| 32 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish and stacking anywhere within the compound as directed. |
| 33 | M. S. clamp for fixing door &window frame. (40mm x 6mm x 250mm.length) |
| 34 | Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts), reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only). |
| 35 | Supplying profiles of required section madeof Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).(A) In 10-12 Micron thickness Annodizingfilm 2- track sliding window Bottom frame |
| 36 | Top and side frame. |
| 37 | Shutter for all track sliding window.- Bottom & Top member. |
| 38 | Style side member. |
| 39 | Interlock member. |
| 40 | Labour charge for fabrication and installationof composite door, window , partitions made from annodized extruded alloy aluminium sections for the following units:-Glazed aluminium sliding windows madeof extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Poly Shulphate sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC.The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleate angle etc. but excluded the cost of extruded aluminium sections, glass, neoprene / EPDM gasketing, locking arrangement and rollers - 2 track sliding window |
| 41 | Supplying bubble free float glass of approvedmake and brand conforming to IS: 2835-1987ii) 4mm thick coloured / tinted / smoke glass. |
| 42 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughlycomplete One Coat |
| 43 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface Two Coats |
| 44 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental Premium 100% Acrylic Emulsion |
| 45 | super protective 100% Acrylic Emulsion |
| 46 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 47 | Making one set of scaffolding only for replacing glass panels, painting,uprooting plant and another repairing works of building and S&P works forexternal works only with 10 cm. dia bamboo as main posts at the rate of 1metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge-3.90 mtr height |
| 48 | Extra for additional 3.6 height or part there of |
| 49 | shifting charge |
| 50 | Taking out rain water down pipes, removing chokages and refixing the same in position including mending good damages (of taking out and refixing) |
| 51 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete -110 mm. Dia.-UPVC Pipes: |
| 52 | Plain Tee |
| 53 | Plain Y |
| 54 | Bend 87.5 degree |
| 55 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.In ground floor32 mm thick |
| 56 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria 66mm x 90mm |
| 57 | Add GST @ 18% EXTRA |
| 58 | ADD CESS @1% Please Enable Macros to View BoQ information |