| 1 | Sorting, counting and loading of Galv. S/S Structure on private truck at EFU Naini | Sorting, counting and loading of Galv. S/S Structure on private truck at EFU Naini |
| 2 | Safe carriage of above loaded structure (1.5 MT) by private truck from EFU Naini to 132 KV Substation, Tulsipur. Distance approx 310 Km. | Safe carriage of above loaded structure (1.5 MT) by private truck from EFU Naini to 132 KV Substation, Tulsipur. Distance approx 310 Km. |
| 3 | Unloading, counting, shifting and stacking of above Galvanised, S/S structure at 132 KV Substation, Tulsipur | Unloading, counting, shifting and stacking of above Galvanised, S/S structure at 132 KV Substation, Tulsipur |
| 4 | Erection of auxiliary structure including shitting of all material from store to site, cutting matching of members, holes if required | Erection of auxiliary structure including shitting of all material from store to site, cutting matching of members, holes if required |
| 5 | Complete erection of following equipment as per technical spesification (including shifting of material from store to site) and all other associated works to complete the job satisfactorily | Complete erection of following equipment as per technical spesification (including shifting of material from store to site) and all other associated works to complete the job satisfactorily |
| 6 | Laying of following sizes of un-armoured PVC Control Cable in cable trenches from control panel to equipment, J.B.'s, ACDB, DCDB etc. | Laying of following sizes of un-armoured PVC Control Cable in cable trenches from control panel to equipment, J.B.'s, ACDB, DCDB etc. |
| 7 | Termination of following sizes of control cable in the cable trench from control & relay panels to various equipment/marshalling boxes/JB ec in switchyard as per cable schedule, its sadding at every 750 mm distance with M.S saddles of size 25x3 mm size including carriage of cable drums from store to laying site and shifting back to store and all other asociated work to complete the jaob satisfactorily. | Termination of following sizes of control cable in the cable trench from control & relay panels to various equipment/marshalling boxes/JB ec in switchyard as per cable schedule, its sadding at every 750 mm distance with M.S saddles of size 25x3 mm size including carriage of cable drums from store to laying site and shifting back to store and all other asociated work to complete the jaob satisfactorily. |
| 8 | Complete earthing of equipment, cable trenches, structures by following size of 11 M.S. Flat including exacavation of trenches and its back filling as per technical specification and standard practice. (MS Flat will be provided by Contractor) | Complete earthing of equipment, cable trenches, structures by following size of 11 M.S. Flat including exacavation of trenches and its back filling as per technical specification and standard practice. (MS Flat will be provided by Contractor) |
| 9 | Painting of M.S. flat size 25x6/ 50x6 mm by using one coat of red oxide primer and two coats of green color ISI marked paint after removing rust. | Painting of M.S. flat size 25x6/ 50x6 mm by using one coat of red oxide primer and two coats of green color ISI marked paint after removing rust. |
| 10 | Supply and installation of junction box of size 280x225x150 mm made of 167 SWG sheet with grey painting suitable for 2x4x6 C 2.5 sq. mm incomming cable and 2x4x6 C 2.5 sq. mm out going cable fitted with 03 Nos HRC Fuse link of 5A, Cable glands, neutral link, terminal block etc. and fixing of junction box on M.S round pole with the help of M.S clamp. | Supply and installation of junction box of size 280x225x150 mm made of 167 SWG sheet with grey painting suitable for 2x4x6 C 2.5 sq. mm incomming cable and 2x4x6 C 2.5 sq. mm out going cable fitted with 03 Nos HRC Fuse link of 5A, Cable glands, neutral link, terminal block etc. and fixing of junction box on M.S round pole with the help of M.S clamp. |
| 11 | Supply & fixing of 1x60 W LED light luminaries (Crompton/Philips/Wipro make) at designated height on light pole including taking out cable from junction box to light fixtures from inside pole, cable terminations, testing, commissioning and its carthing with 12 SWG GI wire. | Supply & fixing of 1x60 W LED light luminaries (Crompton/Philips/Wipro make) at designated height on light pole including taking out cable from junction box to light fixtures from inside pole, cable terminations, testing, commissioning and its carthing with 12 SWG GI wire. |
| 12 | Providing & fixing of 33 KV feeder name plate of 2 mm thick aluminium sheet plate size 600*400 mm with covering retro reflecting sheet base yellow colour & letter blue colour. | Providing & fixing of 33 KV feeder name plate of 2 mm thick aluminium sheet plate size 600*400 mm with covering retro reflecting sheet base yellow colour & letter blue colour. |
| 13 | Shifting & proper stacking of all balance/ unused items from site to sub-station store and levelling & cleaning of site after completion of work. | Shifting & proper stacking of all balance/ unused items from site to sub-station store and levelling & cleaning of site after completion of work. |
| 14 | Bay wise interconnection/jumpering by panther conductor with all associated works from 33KV main bus to all bay equipments | Bay wise interconnection/jumpering by panther conductor with all associated works from 33KV main bus to all bay equipments |
| 15 | PG clamps suitable for Moose/ Panther | PG clamps suitable for Moose/ Panther |
| 16 | PG clamps suitable for Panther / Panther | PG clamps suitable for Panther / Panther |
| 17 | Providing digital insulation tester 5KV | Providing digital insulation tester 5KV |
| 18 | 36KV Isolator clamp suitable for single panther | 36KV Isolator clamp suitable for single panther |
| 19 | Flexible Copper Bond 16 mm dia 500 mm lenth | Flexible Copper Bond 16 mm dia 500 mm lenth |