| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with PVC switch board and fancy type switch with cover plate including connection etc as required:-Short Point :- |
| 2 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with PVC switch board and fancy type switch with cover plate including connection etc as required:-Medium Point :- |
| 3 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with PVC switch board and fancy type switch with cover plate including connection etc as required:-Long Point :- |
| 4 | Providing and fixing of 3 pin 5/6 amps plug point with fancy type 5/6 amps switch and socket with cover plate including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on PVC switch board, earthing the 3rd pin etc. as required:- |
| 5 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.2 X 2.5 sq mm |
| 6 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.2 X 4 sq mm |
| 7 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- 1 X 1.5 sq mm |
| 8 | Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required.254mm x 300mm (10\\" X 12\\") :- |
| 9 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.4 step fan regulator (1M):- |
| 10 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.Blank plate (1M):- |
| 11 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 12 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 13 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 14 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 15 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 16 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 17 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 18 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 19 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 20 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 21 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-32 amps 240 volts DP main switch (rewireable):- |
| 22 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(2+4) / 6 way SPN MCB DB (double door):- |
| 23 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-6 to 32 amps SP MCB:- |
| 24 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-40 amps DP isolator:- Please Enable Macros to View BoQ information |