| 1 | Item Wise BoQ BoQ_Ver3.0 Item Wise Normal INR Only INR Select, Excess (+), Less (-) Tender Inviting Authority: Superintending Engineer, Electricity Construction & Work Circle-2, P.V.V.N.L., Meerut Bought Out Name of Work: Work for (1) Construction of 33/11 KV Substation Kazipur (2×5 MVA) and its associated 33 KV & 11 KV Lines (2) Construction of 33 KV Link Line from 33/11 KV Substation Sardhana Tehsil to 33/11 KV Substation Sardhana Canal. Direct Tender Reference No : 04/ECWC-2/MRT/2026-27 Quote for Supply Portion only Bidder Name : Quote for Erection Portion only PRICE BID1. This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns after validating the sheet, else the bidder is liable to be rejected for this tender.2. Bidders are allowed to enter the Bidder Name and Unit Ex-Works Price and GST in %age only.3. All the material and erection practices shall be as per tender specification.5. Above Schedule Structure and quantities is provisional and may vary as per site requirement with due approval.6. Indicative scope of works and quantity of Items/Materials required for above work shall be as per the Price Bid. Any other material if required to complete the job and not mentioned above, shall have to be provided by the bidder without additional cost.7. Financial evaluation and selection of 'L1 Bidder' shall be done on the basis of total amount. The rates received in the tender will be final after the approval of the Competent Authority/Committee and the competent Authority/committee will have the right to negotiate in tender rate/amount.8. Tenderer must be fill-up the enclosed terms & conditions sheet and attached with 1st Part of Tender as well as scanned copy of same will be uploaded on NIC Website alongwith other documents.9. Bidders must be filled up the GST in %age, Otherwise it is assumed G.S.T. rates are included in the given ex-works price (Rs./Unit). NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Works Item Code Tender Qty. Unit Estimated Rate Bought-out/Direct Specify Bought-out/Direct Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Unit Ex-Works Price(Rs./unit) Excise Duty(Rs/Unit) CST/VAT(Rs/Unit) Other Taxes & Duties(Rs/Unit) Freight & Insurance Charges(in Rs./Unit) Unit FOR Dest. Supply Price incl. all Taxes and Duties(in Rs./Unit)(F+G+H+I+J) Total Value for Supply or Erection (In Rs.)(C x F) GST (in Rs.) in %age Total Value for GST (in Rs.) (F*M/100) Total Unit Price incl. GST (in Rs.) Total Amount excl. GST (in Rs.) (4×13) Total Amount incl. GST (in Rs.) (4×26) TOTAL AMOUNT In Words |
| 2 | Supply by Contractor :- (Items provided as per GTP/Respo Drawing)Stone Pad |
| 3 | Cross Arm Hold Clamp with Bolts & Nuts |
| 4 | Bracket Clamp for Top Channel TPMO & Fuse Set etc. with Bolts & Nuts |
| 5 | Al. P.G. Clamp Dog to Dog |
| 6 | F-Bracket for 33 KV Line |
| 7 | E-Bracket for 33 KV Line |
| 8 | E Bracket with Bolts & Nuts |
| 9 | Al. Binding Wire 6 SWG |
| 10 | Barbed Wire GI |
| 11 | Danger Board with Clamp |
| 12 | Number Plate with Clamp |
| 13 | Aluminum Paint |
| 14 | Red Oxide Paint |
| 15 | 2x2.5sqmm Control Cable (armoured) |
| 16 | 4x2.5sqmm Control Cable (armoured) |
| 17 | Galvanised Structure for Bus Isolator (125x65x6mm, 75x75x6mm & 65x65x6mm) / Line Isolator |
| 18 | Galvanised Structure for Fuse Set (125x65x6mm & 75x75x6mm) |
| 19 | Galvanised Structure for Post Insulators (125x65x6mm & 75x75x6mm) |
| 20 | Galvanised Structure for Lightening Arrestor (125x65x6mm & 75x75x6mm) |
| 21 | Galvanised Structure of P.T (125x65x6 & 75x75x6mm) |
| 22 | Galvanised Structure of C.T (125x65x6 & 75x75x6mm) |
| 23 | Galvanised Angle 65x65x6mm, bracing set (4300x2)mm long with clamp |
| 24 | Galvanised Angle 65x65x6mm, bracing set (2700x2)mm long with clamp |
| 25 | Galvanised Angle 75x75x6mm |
| 26 | Galvanised Channel 100x50mm, 3200mm long |
| 27 | Galvanised Channel 100x50mm, 2400mm long |
| 28 | Galvanised Channel 100x50mm, 2240mm long (Top Channel for feeder D/P) |
| 29 | Galvanised Channel (Dropper) 100x50mm, 2028mm long (for feeder D/P) |
| 30 | Galvanised Channel 100x50x6mm (Extra Side Bracket) |
| 31 | Galvanised Channel 125x65mm, 3200mm long |
| 32 | M.S Round 32mm Dia |
| 33 | MS Nut & Bolts |
| 34 | G.I Pipe 150 mm Dia, 3 mtr long |
| 35 | 33KV CT Junction Box/33KV single phase PT |
| 36 | Holding Clamp for GI Pipe |
| 37 | Holding Clamp for Channel and Angle |
| 38 | C.T Connector for providing Input & Output coneection |
| 39 | HDPE Pipe PE-100, PN-6, DN-160mm dia |
| 40 | HDPE Pipe PE-100, PN-6, DN-110mm dia |
| 41 | Earthing Rod (2540×20mm) |
| 42 | Loading, Safe carriage & unloading of following stock material from any stores centres under PVVNL, depending upon the availability of material at Stores Centres, with loading & unloading at both ends respectively. (for Item No. 45 to 102)13 Mtr. STP-SP-72 |
| 43 | 11 Mtr. PCC Pole |
| 44 | 9 Mtr. PCC Pole |
| 45 | 8.5 Mtr. PCC Pole |
| 46 | 5 MVA Power Transformers |
| 47 | 11KV/0.433 KV, 3 Phase, 63 KVA Transformer (BEE standard, 3 star rating self protected type), Al. wound |
| 48 | 33KV 3x300 mm2 XLPE Al. Cable |
| 49 | 11KV 3x300 mm2 XLPE Al. Cable |
| 50 | 11KV 3x185 mm2 XLPE Al. Cable |
| 51 | 33KV Disc Fitting 70KN |
| 52 | 33KV Disc insulator 70KN |
| 53 | 11KV Disc Fitting 45 KN |
| 54 | 11KV Disc insulator 45KN |
| 55 | 33KV Pin insulator 70KN (Polymeric) |
| 56 | 11 KV Pin insulator 45 KN (Polymeric) |
| 57 | ACSR Rabbit/Weasel Conductor |
| 58 | ACSR Dog Conductor |
| 59 | LT XLPE Cable Al. 3.5×70 sq.mm |
| 60 | 11 KV V-Type Cross Arm |
| 61 | 33 KV V-Type Cross Arm |
| 62 | Earthing Rod (2540×20mm) |
| 63 | Stay Wire 7/10 SWG |
| 64 | Stay Wire 7/8 SWG |
| 65 | G.I. Wire 6/8/10 SWG |
| 66 | Stay Set 16x1800mm with stay wire complete |
| 67 | Stay Set 20x1800mm with stay wire complete |
| 68 | 11 KV VCB I/C CTR 600/300/5 A, 350 MVA |
| 69 | 11 KV VCB O/G CTR 200/100/5 A, 350 MVA |
| 70 | Line Isolator 800 A, 33 KV |
| 71 | Bus Isolator 800 A, 33 KV |
| 72 | Lightning Arrestor 33 KV |
| 73 | 3-Phase D.O. Fuse Set |
| 74 | 11 KV Fuse Set |
| 75 | 33 KV Fuse Set |
| 76 | 11 KV TPMO with Polymer Insulator |
| 77 | 33 KV CT, 200/100/1-1A |
| 78 | 33 KV PT (outdoor) 33 KV/110 V) |
| 79 | 33 KV VCB, 800, 750 MVA |
| 80 | Various Type of Jointing Kit (indoor/outdoor) |
| 81 | Battery and Battery Charger 24 Volt |
| 82 | 11 KV Bus Coupler |
| 83 | 33 KV Control Panel for Double Transformer |
| 84 | 33 KV Post Insulator |
| 85 | Terminal Gantry :-Providing, Making of Terminal Gantry structure as per respo, UPPCL specification by the contractor. (Item No. 103 to 108)Construction of terminal gantry as per details:- Excavation of earth for making 2 Nos. pits of size (1.4x0.75x2.2)M. All civil material provided by the Contractor on his own cost. |
| 86 | Fabrication of Terminal Gantry by using 4 Nos. of 8.70 M long (175x85)mm, 19.5 kg/meter or (100x116)mm, 23.1 kg/meter R.S. Joist with bracing of the same by M.S. Angle iron or size (50x50x6) mm & providing & fixing 2 Nos. of 3.2 m long pieces of M.S. Channel of size (125x65x6)mm for Top as well as Dropper channel & Composite Polymeric Pin insulator. The work also includes cutting, drilling and welding with alignment etc. for proper completion of work. R.S.Joist & All civil material Must be provided by the Contractor on his own cost. |
| 87 | C.C. work in ratio of 1:3:6 (cement, fine sand and brick ballast) of size (1.40x0.75x0.15)m for 2 Nos. pits for making bed. Work includes proper ramming etc. All civil material provided by the Contractor on his own cost. |
| 88 | C.C. work of ratio 1:3:6 (cement, coarse sand & 20 mm size stone grit) for the structure of 02 Nos. of pre-fabricated legs of terminal gantry (8.2 m long) as per drawing No. RES-38 size of plinth (1.4x0.75x2.7)m. All civil material provided by the Contractor on his own cost. |
| 89 | 12mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) of plinth of 0.4 m upper side, All civil material provided by the Contractor on his own cost. |
| 90 | Stone pad 300x300x75 mm |
| 91 | Bus-Bar Gantry :-Providing, Making of 33KV Main Bus-Bar complete with structure on ACSR Panther conductor with all PG clamp and connector as per RESPO Norms by the Contractor. (For item No. 109 to 113)Excavation of earth for making 4 Nos. pits of size (0.75x0.75x1.7) M |
| 92 | Fabrication of Bus Bar Gantry by using 04 Nos. 6.4 m long 90 lb/105 lb Rail and M.S. Angle (50x50x6) mm for cross bracing of Bus-Bar and providing top channel of size (125x50x6)mm as per drawing RES-38. The work includes cutting, drilling, bolting and alignment of the same for proper completion of work. R.S.Joist & All civil material Must be provided by the Contractor on his own cost. |
| 93 | C.C. work of ratio 1:3:6 (cement, coarse sand and 02 Nos. structure, pre-fabricated Bus-bar Gantry size of Plinth (0.75x0.75x2.10)m, 4 Nos. after proper ramming over stone pad. |
| 94 | 12mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) or plinth of 0.4 m upper side. |
| 95 | Fixing of stone pad |
| 96 | Excavation of earth, Grouting of structure in C.C. ratio 1:4:8, Erection of Line/Bus Isolator structure in proper alighment., Making plinth by C.C. ratio 1:3:6 and 12mm thick plastering on plinth in ratio 1:4 |
| 97 | Excavation of earth in size, making fabrication & erection of structure by making plinth C.C ratio 1:3:6, 12mm thick plasting on plinth in ratio 1:4 : (as per specification) (for item No. 115 to 119)Post insulator structure |
| 98 | P.T structure |
| 99 | 33KV C.T Strucure |
| 100 | 33KV Fuse set structure |
| 101 | 33KV L.A Structure |
| 102 | Installation of 33KV Bus Isolator/Line Isolator with structure, Fabrication, excavation, erection, grouting (with cement, coarse sand and stone shingle) and making of plinth of BUS ISOLATOR STRUCTURE as per RESPO, UPPCL Drawing, as per PVVNL guidline and site requirements.Fabrication of Structure, including cutting, straightening & drilling of holes in Channel/Angle including supply of materials. |
| 103 | Construction of plinth for the structure of 33 KV VCB as per details (for Item No. 121 to 132)a) Excavation of earth of size (2.4×1.5×1.0) m pits for construction of plinth. (3.6 Cum) |
| 104 | b) Brick Ballast ratio (1:4:8) (cement, sand & brick ballast ) for foundation work (2.4×1.5×0.15)m plinth. (0.54 Cum) |
| 105 | c) C.C. work in ratio 1:2:4 (cement, coarse sand &stone grit) of 20mm size for making plinth of size (2.4×1.5×1.00)m and grouting of foundation bolts 04 Nos. for 33 KV VCB. (3.6 Cum) |
| 106 | d) 12 mm thick plaster with cement mortar in ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level size (2.4×1.5)m. (4.77 Cum) |
| 107 | e) Assembling and installation of 33 KV VCB on the VCB out door structure on the plinth.Adjustment of operating mechanism in proper alignment for smooth operation of the same. The work also includes fabrication of addition arrangement for proper fixing, if required and also safe removal of old 33KV VCB if applicable. |
| 108 | Installation & mounting of materials on erected structure (The Work also includes safe removal of old items present in acquired land)iv) Mounting of 33KV L.A |
| 109 | iii) 33KV C.T (200/100/1A, 400/100/1A) |
| 110 | ii) 33KV PT |
| 111 | i) Mounting of 33KV Post Insulator |
| 112 | iii) Mounting of 33KV Fuse Set |
| 113 | vi) Fixing of 33KV CT Junction Box |
| 114 | vii) Fixing of C.T Connector for providing Input & Output coneection |
| 115 | Construction of Plinth for 5MVA/10MVA/20 MVA, 33/11KV T/F as per drawing & PVVNL guidline and site requirements, details as given below:-Excavation of earth in foundation. Cement concrete in foundation in ratio 1:6:12, Cement, Sand & Brick ballast., First Class Brick work in ratio 1:4 with Cement & Coarse sand mortar., Cement concreting inner side of plinth in ratio 1:4:8, Cement, Coarse sand and stone shingle. M.S.work for re-inforcement 12mm. Tor at a distance of 15Cms. apart, including cutting, bending & binding by wire to each other for making JAL in two layer, 12 to 15Cms. apart. |
| 116 | Providing & Fixing of 3.5Mtr.long, 2No. Rail Pices, 90Lbs, on top of Plinth at proper distance in alignment by C.C. |
| 117 | Cement concrete in ratio 1:2:4, Cement, Coarse sand & Stone shingle, on top of the plinth, including fixing of M.S.Tor Jal. 12mm.thick Cement Plaster in ratio 1:4, Cement & Sand mortar, on all side of plinth, Neat cement coating 3mm.thick on top surface of plinth. |
| 118 | Earthmate :-M.S Round 32mm dia and all requried material for Substation earthmate provided by the contractor his own cost. (3500Kg approx)Earthing of Outdoor Equipments in Switchyard, as per site requirement/as per PVVNL guideline details as given below:-Digging of Trench of size-0.50x0.75x30M.,for laying of Earthmat throughout in required full portion of switchyard and refilling & ramming of the same earth into the trenches after completion of Earthmat work, Laying of 32mm.dia M.S.Bar in Trench, properly in alignment along the length and width in switchyard, Cutting of 32mm.dia M.S.Bar-3M.long and making one end in conical shape,by forging process and driving it into the earth, in trench at fixed distance as per drawing and properly welding with M.S.Bar Earthmat, Proper continuous electric welding of overlap joints of M.S.Bar upto a length of 150mm. On both sides,along the length of M.S.Bar and an extra piece of 12mm M.S.Round-150mm.long, providing on both sides of Overlap Joints and continuous electric welding on both side, along the length of M.S.Bar. All joints shall be painted with black bituminous paint, Proper electric welding at X-joints of M.S.Bar and welding by providing 25x6mm.”U” type Clamp of M.S.Flat, and proper continuous electric welding with M.S.Electrode and M.S.Bar at each X-joints. All joints shall be painted with black bituminous paint and as per site requirement. |
| 119 | Providing &laying of G.I.Strip of size 50x6mm for connecting the earthmat with each equipment (Bus Isolators, 33KV C.T., 33KV V.C.B., L.As., Fuse Set, Post Insulators, T/F Body & its neutral and M.S.Frame of Cabe Supporting Structure), various steel structures. The work also includes cutting, bending, straightening, over laping and welding the earth strip with earth mat and by using high quality arc welding in already digged trenches, as per PVVNL guidline and as per site requirement. |
| 120 | Installation of 11 KV Switchgears in Control Room Carefully & safely shifting of 11 KV switchgear panels from outside to inside the switch gear room grouting foundation of bolts in C.C. ratio of 1:2:4 (including cutting of RCC floor and finishing of RCC floor) as per requirement placing, aligning and fixing of 11 KV anchor GI bolts and nuts of proper size for completion of work in all respect. |
| 121 | Proper fixing and making bus bar connection in between two switch gears after proper cleaning. Work also include proper insulation, taping by empire, PVC and H.T. tape etc. |
| 122 | Making earthing of all 11KV Switchgears, P.T. and other outdoor equipments on both earth terminal inside the control room by providing G.I.Strip in size 50x6mm. with 32mm. dia M.S.Round laid in trench with proper electric welding, as per PVVNL guidline. |
| 123 | Laying, Stringing & Sagging of ACSR Dog/Panther Conductor from main Bus Bar to Power T/F, through Post Insulator, Bus Isolator, C.Ts, VCB and L.As., by providing & fixing P.G.Clamp/Connectors, suitable for Dog/Panther. |
| 124 | Earthing of L.A's & Transforer neutral : Making of delta with 03 No. 03mtr. 32mm dia M.S. round bar electrode and Fabrication of 32 mm dia bar for 3.0 m long electrodes and digging them into ground so that the top of M.S. Round/Electrode remains at least 0.75m in air and jointing of earth electrode with the delta by using 75mm long piece of M.S. Round using high quality Arc welding and paints of joints with black bituminious paint by providing MS round 32mm dia and all required material. |
| 125 | Construction of Control cable trench as per details (143 to 152)Excavation of earth in size 0.650x0.40m. |
| 126 | C.C. work in foundation in ratio 1:3:6 (cement, sand & brick ballast) with proper ramming in size 0.65x0.15 mtr.) both side |
| 127 | First Class Brick work in cement mortar in ratio 1:4 in size 0.23x0.32 Mtr. Both side |
| 128 | 25mm thick C.C. in floor of Cable Trench in ratio 1:2:4 (cement, coarse sand and stone ballast) 20mm gauge in size 0.3 mtr. Width. Both side |
| 129 | Grouting of M.S. Strip of size 450x25x6mm in cable trench 100mm above floor level and at equal space distance 300mm. |
| 130 | Grouting of M.S. Angle Iron of size 50x50x6mm in upper edge of trench. |
| 131 | Plastering of Trench in Cement, Mortar in ratio 1:4, 12mm thick in cable trench. Both side |
| 132 | Fabrication and fixing cable trench cover of M.S. Angle size 50x50x6mm of size 0.3m wide 0.5 to 1.0 mtr. Length with proper welding of 8 mm size of bar 2 Nos. in length and 6 Nos. in width including cost of CC casting & RCC in Ratio 1:2:4 (cement, coarse sand and stone ballast) (ii) 1.00 Mtr. Long |
| 133 | Laying of Control Cable in Packka Trench, from VCB/CTs/T/F to 33KV Control Panel and making connection for operation & protection of equipments, by using ferrules including commissioning battery charger with battery by providing copper lead with lugs etc & dressing of Control Cable and making arrangement for testing in the equipments. |
| 134 | Installation of 33/11 KV Power Transformer (for item No. 153 to 157)Shifting of available Power Transformer to transformer plinth in Switch Yard. |
| 135 | 5 MVA |
| 136 | Erection of shifted Transformer at plinth by fixing all accessories like radiators, conservator tank, filling the transformer oil to desired level and ensuring that there is no leakage, complete job in all respect. (for item No. 159 to 162) Including Repairing /replacement of OTI/WTI/Silicagel Breather ,33KV/11KV Bushing and attened Oil seapage/leakage if required complete in all respect to complete the job by providing required materials & T&P by the firm at his own cost. |
| 137 | 5 MVA |
| 138 | Water level earthing by Boring and lowering by providing of G.I.Pipe size 40mm dia of 2mm thickness, into the ground upto water level or minimum 50Mtr, which ever is more, with the lower end of solid copper cone Approx 224mm long and 750gm in weight shall be provided and screwed in pipe as well as bringing out a continuous 6SWG copper wire, from the cone upto the ground surface where it will be bolted to the G.I. Strip for Transformer neutral connection, the G.I.Strip will be connected to star point through providing Copper Bond Strip of size-50x6mm. |
| 139 | Providing & Fabrication and erection of neutral earthing L Type support made of G.I Channel size 100x50mm. Structure shall be 4 Mtr. Long with 1 Mtr. Arms. Structure shall be grouted in ratio 1:3:6 in block size 300x300x700mm and painted of welding joint with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint work includes connecting neutral bushing rod of power Transformer and G.I. Earthing strip with the help of flexible copper bond, G.I Bolt and washer. |
| 140 | Providing & Fabrication and erection of cable support made of two pieces of M.S.Channel (100x50x6)mm, 2.75 meter long, joined to each other by means of 5 Nos. M.S. Flat (50x6) mm pieces of size 750 mm long each by welding at equal intervals and grouting in a block of size (300x300x700)mm in C.C. 1:3:6 (cement, coarse sand and stone ballast) complete and painted of welding joint with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint. Work includes providing of three Nos. M.S. clamps made of (50x6)mm M.S. Flat for holding the cable including nuts and bolts. |
| 141 | Providing & Fabrication and grouting of M.S. frames 3.60 mt. long for support of copper Bus Bar. Bus Bar will be provided in L.V. side of Power transformer. The M.S. frame shall be made of M.S. channel (100x50)mm in ‘T’ shape. Providing 2 Nos. support of M.S. Angle iron (50x50x6)mm, 0.60mt. long below the top channel, drilling of 3 Nos. hole on the top channel for fixing of 11 KV pin insulator and painted of welding joint with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint and grouting the frame in C.C. ratio 1:3:6 (cement, coarse sand and stone ballast) in a block of size (300x300x700) mm. The work also includes the fixing of 3 Nos. 11 KV pin insulator with pin and binding the copper Bus Bar with the pin insulator by Aluminium binding wire in complete. |
| 142 | Supply & Fabrication of copper bus bar of size (2400x50x6)mm in L.V. side for 05MVA and (3000x65x8)mm for 10MVA T/F as per requirement for power transformer, Work includes connection of outside bus bar in L.V. side busing rod of Power Transformer and other side with outdoor 11 KV cable box as well as providing empire tape and H.T. tape etc. for proper insulation work covering copper Bus-Bar in Complete. |
| 143 | Fixing of Cable Box on 5MVA/10MVA T/F, 11KV Switchgears, by Bolt & Nuts and tapping the joints by providing HT/Empire/PVC Tape. |
| 144 | Mounting of 11KV Cable boxes on Double Pole, by providing & fixing of M.S.Clamp, made of 65x6mm. M.S.Flat, with Bolts,Nuts & Washers, including providing & fixing 3mm. thick 150mm. dia G.I.Pipe-3M.long, with pipe supporting Clamp-2No. on each, made of 65x6mm M.S.Flat. |
| 145 | Installation of 11 KV Switchgears in Control Room Carefully & safely shifting of 11 KV switchgear panels from outside to inside the switch gear room grouting foundation of bolts in C.C. ratio of 1:2:4 (including cutting of RCC floor and finishing of RCC floor) as per requirement placing, aligning and fixing of 11 KV anchor GI bolts and nuts of proper size for completion of work in all respect. |
| 146 | Installation of Double Transformer control panel |
| 147 | Safely mounting of 11 KV PT on 11 KV incoming switch gear filling of oil (if required) making all electrical connections and testing & commissioning of work. |
| 148 | Proper fixing and making bus bar connection in between two switch gears after proper cleaning. Work also include proper insulation, taping by empire, PVC and H.T. tape etc. |
| 149 | H.T. Power Cable Laying: Double circuitLaying 11 KV/33KV, (3x300) mm2 XLPE, Cable from power transformer to 11 KV incoming switch gear in the cable trench 0.45 m wide, 0.90m depth. Providing 150 mm local sand for cushion beneath and 150 mm above the cable (quality of local sand required 0.375 cum/m in length). The cable shall be dully protected by brick. On both side of cable by laying brick vertically and bricks would also be laid bricks along the single cable (minimum 18 Nos. of bricks are to be laid top and outer side along the single cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal’s, back filling of earth and testing and commissioning of power cable etc. Spare cable shall be left over and laid in the trenches in shape of 6 m ring at both ends. |
| 150 | Laying and dressing of 11 KV 3x300 mm2 power cable in air/Trench. Double circuit |
| 151 | Laying 11 KV, 3x185mm2 XLPE, Power cable from outgoing switch gear to 11 KV double poles in the cable trench 0.45m wide, 0.90m depth. Providing 150 thickness mm local sand for cushion beneath and 150mm above the cable (quantity of local sand required 0.375 cubm/m in length). The cable shall be duly protected by brick. On both side of cable by laying bricks vertically and bricks would also be laid horizontally on top of vertically laid bricks along the single cable (minimum 18 Nos. of bricks are to be laid top and outer side along the single cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal’s, back filling of earth and testing and commissioning of power cables etc. Spare cable shall be left over and laid in the trenches in shape of 6m rings at both ends. At the end of feeder cables, where the cable is to be laid across pucca/main road, 100 mm dia M.S. pipe will be weared over the cable in the cable trench for the protection of cable. (Single Circuit) |
| 152 | Laying and Dressing of 11KV 3x185mm² Power Cable in Air. (Single Circuit) |
| 153 | Supply and filling of sand in cable trench in the Switch Gear Room. |
| 154 | Painting of StructuresPainting of the following structure with one coat of ready mixed primer and two coats of ISI Mark Aluminium paint after rubbing with sand paper to the surface of the structure including labour and T&P complete in all respect.(i) All M.S.Steel structure. |
| 155 | (ii) All body painting of Old & Used Power Transformer and Topup the transformer oil in Transformers and meetout likage, change oil seal, pecking etc. Change of OTI, WTI and breather including silica gel (if required) |
| 156 | Preparation of 11 KV Power Cable ends: 3x300sqmm/3x185sqmmMaking of 11 KV XLPE Heat shrinkable outdoor jointing kits after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs |
| 157 | Making of 11 KV XLPE heat shrinkable indoor jointing kits in switch gears after carefully removing the insulation of cable, providing and crimping of proper size of lugs, plumbing and taping of cable with good quality available insulation tape with J/Kit boxes, Fixing and insulating of lugs on cable with switch gear complete in all respect. |
| 158 | Laying of different size of (2x2.5)mm2control cables i.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT’s to CT’s Junction Box, 33 KV CT, 33 KV PT, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment. |
| 159 | Laying of different size of (4x2.5)mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT’s to CT’s Junction Box, 33 KV CT, 33 KV PT, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment. |
| 160 | Fabrication of L.T. distribution board by using M.S. Angle size (65x65x6)mm of size (2x0.75x1.4)m and grouting the stand in ground floor in switch gear room at proper place. 12 mm thick Indian wooden ply with sunmica top will be fixed on the ply frame and frame will be painted by one coat of primer red oxide and two coats of smoke grey paint. |
| 161 | Providing & wearing of 110 mm dia 3.5 mm long G.I.Pipe in the feeder cable of size of (3x185/3x300)mm2 XLPE 11KV power cable before making the outdoor cable boxes. The work includes the sealing of M.S. Pipe, top end and lower end of the pipe is to be buried in to the ground about ½ m and proper dressing of cable etc. The work includes lifting, mounting and clamping of 11 KV feeder cable boxes on the feeder with double pole structure and making connections including supply of cable mounting clamps etc. (all required materials provided by the firm) |
| 162 | Providing & Fixing 110mm dia 2mtr long G.I pipe on the cable stand |
| 163 | Plinth of Substation T/F with RCC Top of size 2x2x1.6 Mtr. Incl. 2 nos. M.S. Channel of 125x65x6mm as per specification |
| 164 | Installation of 11/0.4 KV, 63 KVA T/F on Plinth and providing and fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm on LT bushing Rod of S/s T/F and making of 11 KV & L.T.Connections of Transformer complete including earthing of T/F with chemical Pipe earthing the work in all respects. |
| 165 | Installation of 24V Battery and Battery Charger:Assembling and installation of the cabinet of 24V battery and battery charger in switch gear control room including grouting of foundation bolts as per drawing of manufacture, including providing the foundation nuts and bolts of proper size. The electrical connection between battery and battery charge with flexible copper lead of size 7/20 SWG shall be done properly. The work includes installation, wiring upto control panel, testing and commissioning complete in all respect. |
| 166 | Providing & Fixing 100amp TPN MCCB, 4 Pole and 4 nos. 32amp single phase, MCCB in box as per catalogue no. 607780 ligrant make or equivalent. |
| 167 | Construction of 11 KV Feeder Double Poles:Erection and grouting of 2 Nos. PCC 11Mtr long for making DP Structure including fabrication fixing of G.I Channel, M.S.Angle, TPMO, Fuse Set, disc, insulators, pin insulators and providing and fixing No. Plate, Danger board, barbed Wire (02 Kg per Pole), stone pad etc. the work includes supply and fixing of necessary clamps size 75x10mm with G.I Nuts bolt & washer, bolts and washers. The work also includes grouting of Double pole support in C.C. 1:3:6 (cement, Core sand & stone ballast) in block of size (0.45m x 0.45 x 1/6 length of the pole) including earthing of Double pole with M.S. earthing rod complete in all respect. |
| 168 | Fixing of SMC Danger board at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with M.S.Clamp & nut & bolt for 11KV |
| 169 | Grouting of stay rods (16x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc. (all required civil materials provided by the firm) |
| 170 | Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps. |
| 171 | Tripping, Single line diagram, Board & Substation layout:Providing & fixing of single line diagram board for 33/11 KV substantions of size (1200x900)mm made of Indian Plywood 6 mm thick fitted on wooden frame made of Sal wood of size (50x30)mm. Two support of Sal wood of size 1200 mm and two supports of size 900 mm shall be tapered on the front side and properly finished, the board shall painted with white enamel paint in two coats after one coat of primer shall be used in both side. The prescribed matter/chart shall be written neatly with red, green and black paint as required & providing 04 Nos. copyes of layput of substation after survey on A-2, Paper. |
| 172 | Fabrication, Erection & Grouting of 33/11KV S/S Name Board of size (0.75x1.5) Mtr 2.40Mtr high frame of M.S. Angle of size 50x50x6mm, Two cross Bracing of M.S. Flat of size 25x6mm shall be fixed with frame, Board shall be made of 18SWG M.S. sheet of size .75x1.5mtr shall be fitted in frame with Rivit Board letter should be written by black paint on yellow back ground Providing All required materials by the contractor own his cost. |
| 173 | Supply & fixing of copper clamps such as Isolator, LA, Transformer end clamp, fuse set, post insulator, PG clamp etc. complete with nut, bolt & washer for Dog / Panther Conductor |
| 174 | Making plinth of street light, support in CC 1:3:6 of size 45 cm dia & .30 mtr. In height complete with all labour T&P etc. Providing street pole with light as per specification (08 No.) |
| 175 | Construction of Fire Protection wall as per RESPO Drawing & specification. |
| 176 | Construction of SSO’s approached road 1.2 Mt wide in switch yard by laying dry brick ballast in 15 cm layer, 115 mm thick brick work 1:4 in both side of edge, providing 10 cm thick CC in ratio 1:2:4. The work include proper plastering top & side of road and making groove, leveling & dressing of earth beneath the brick work on edge. All required materials provived / supply by the contractor own his cost. |
| 177 | To provide required No. of technicians to work on power T/f, HT/LT panels & 33KV line during testing as assisting technical hands of test team during commissioning & energisation (Testing & Commissioning). |
| 178 | Hiring of D/G Set, including carriage, loading, unloading & operating charges (with fuel) at 33/11KV Substation, :20 KVA, 3 Phase D/G Set for testing of Power T/F & equipments installed at Sub-station. |
| 179 | Supply & fixing Fire Fighting Equipment of approved make 4.5 Kg Co2 Fire extinguisher portable type. |
| 180 | 5 Kg Dry Chemical Power Fire extinguisher portable type. (Supply & Fixing) |
| 181 | Fire bucket stand with 6 nos. bucket (Supply & Fixing) |
| 182 | Rubber Mat 1Mtrx2Mtr thikness 20mm, (Supply & Fixing) |
| 183 | Substation Furniture. (Supply & Fixing)1 no office chair, 1 no office table, 1 no Bench size 6x1.1/4, 1 no Rack, 1 no steel stool & 1 no Almiraha. |
| 184 | T&P of Substation of switchgears (Supply as per specification) |
| 185 | 33KV LineThe excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I Nut bolt & washer, V-type X-arm, Pin Insulator, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. (for Item No. 222 to 224)Single Pole(a) 09M Long PCC Pole |
| 186 | (b) 11M Long PCC Pole |
| 187 | (c) 13M Long STP, SP-72 Round Pole |
| 188 | The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I .Clamps size of 75x10mm, 65x8mm, G.I Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I Angle 65x65x6mm. The work includes cutting holes and providing G.I Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. (from Item No. 225 to 233)(i) Double Pole Structures(a) 09M Long PCC Pole |
| 189 | (b) 11M Long PCC Pole |
| 190 | (c) 13M Long STP, SP-72 Round Pole |
| 191 | Riser Double PoleThe excavation of foundation pit in mix soil/normal soil/soft soil & hard rock and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps size (65x8mm), Nut bolt & Washer, Stone Pad, Lugs, Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports & hardware material from sectional store to pit site as well as an fabrication work if required. Fixing of 04 Nos.G.I Channel 100x50x2.4Mtr (With arrangement of 06 Nos. 33KV Pin insulator with Pin). The work also includes cutting of channel/angles, making holes on G.I Channel / G.I Angle, spring washer of proper size for channel/angle. Contractor also provide G.I Channel clamps and E- clamps at his own cost as per Respo Norms.(a) Riser Double Pole on 11M PCC Pole |
| 192 | Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming.(i) Single Pole(a) 09M Long PCC Pole |
| 193 | (b) 11M PCC Pole |
| 194 | (c) 13M Long STP, SP-72 Round Pole |
| 195 | (ii) Double Pole Structures(a) 09M Long PCC Pole |
| 196 | (b) 11M Long PCC Pole |
| 197 | (d) 13M Long STP, SP-72 Round Pole |
| 198 | (e) Riser Double Pole 11M Long PCC Pole |
| 199 | Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc. |
| 200 | Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 33KV and Stay Clamps. |
| 201 | Earthing of supports with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S.Rod 3.0M apart from suppor and 0.5M below the ground level and connecting belowl the earth electrodes with the help of M.S.wire No.8SWG, M.S.Nut bolt & washer and earthing lugs. |
| 202 | Laying, spreading, lifting and final sagging of 3 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel. |
| 203 | Making Jumpers on Sectional Pole, by providing & fixing of P.G.Clamps of proper sizes, suitable for Dog Conductor/ 33KV, 3x300Sq.mm XLPE cable. (from Item No. 256 to 258)(a) Sectional Double Pole |
| 204 | (b) Riser Double Pole |
| 205 | Guarding between two poles like single poles, double poles, four poles, etc. to guard L.T., 11KV Line telephone line and river crossing, road crossing etc. with G.I wire.6SWG, G.I wire No.8SWG and G.I .wire No.16SWG including cutting with fabrication and fixing of G.I Guarding angle 75x75x6mm with Providing & fixing G.I .clamps size 75x10mm, G.I Turn buckle, G.I .Eye bolt, nut bolts & washer etc, as per drawing. |
| 206 | Providing & fixing of SMC Danger board at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with M.S.Clamp & nut & bolt for 33KV |
| 207 | Providing & fixing of SMC Number Plate at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with M.S.Clamp & nut & bolt for 33KV Line. |
| 208 | Making H.T.Connection of the proposed line from 33KV Line. The work consists of fixing & fabrication of Dropper Channels, & fixing of Disc Insulators, Pin Insulators, jumpering with P.G.Clamps, clamping and binding etc,as per site conditions. |
| 209 | Providing & Wrapping of barbed wire (2.0Kg per Pole) on 33KV ST Poles SP-55/SP-72 as anti-climbing device for a length of 0.9Mtr. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75Mtr. from the ground, complete with providing and fixing of lower end & upper end clamps made of M.S.Flat 40x5mm complete with nuts & bolts. |
| 210 | (b) 13Mtr SP-72 Poles including all channels/x-arms/clamps etc.: |
| 211 | UG Cable (HDD Method) 33 KV (Railway Crossing /Road Crossing including NHAI)Digging of Pit by excavation of earth of 1600x1600mm size for 33KV line |
| 212 | Laying of HDPE Pipe PE-100, PN-6, DN-160mm dia by HDD trenchless method, as per site requirement. |
| 213 | Laying of 33KV, 3x300Sq.mm XLPE cable in HDPE Pipe PE-100, PN-6, DN-160mm dia by HDD trenchless method, as per site requirement. |
| 214 | Back filling of excavated earth in the pit upto the ground level and ramming properly. |
| 215 | Safe laying of 33KV, 3x300Sq.mm. XLPE Cable in Cable Trench to respective Double Pole. |
| 216 | Providing & Laying of Ist Class Bricks, along the length on both side of 33KV XLPE Cable in Cable trench and Stone Slab of size 450x600x40mm on top of the Cable, Providing 75mm thickness River sand for cushion beneath and 75mm above the cable as per specification. |
| 217 | Laying of 33KV, 3x300Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & M.S.Pipe and making connection with 33KV over head line at both ends. |
| 218 | Providing and fixing 150mm dia (Minimum 2mm thick) 2mm thick 3M long G.I.Pipe over 33KV, 3x300Sq.mm XLPE Cable before mounting the 2No. Cable on double pole. Work includes providing & fixing of Clamp, sealing of top and bottom end of the G.I.Pipe. One end of G.I.Pipe is to be buried under earth about 500mm. |
| 219 | Making of 33KV Outdoor type cable end termination by heat shrinkable XLPE Cable Jointing Kits and crimping with proper size aluminium lugs. Work includes providing Aluminum lugs, insulating tapes etc as per specifications. |
| 220 | Supply & fixing of cable route marker along the route of 33KV cable with proper grouted with proper painting & marking PVVNL, 33KV HT Cable. |
| 221 | UG Cable (Open Trench Method) 33KVDigging of Trench by excavation of earth of 1050x750mm size for 33KV line |
| 222 | Laying of 33KV 3×300mm2 Cable & back filling of earth including Supply & Laying of Ist Class bricks work for making chulla and sand work for cushin.and stone slav over the chulla |
| 223 | Safely laying of 33KV 3×300mm² XLPE cable along with spare cable into trench including loop |
| 224 | Safe laying of 33KV XLPE cable in Air on Double on D/P/Riser |
| 225 | Road restoration charges for 1Mtr wide Kuccha Road-Pucca Road (Inter locking Tiles, Bricks Road (Cemented, Concrete & Black road only) & Developed green belt only) or Deposite charges to take the permission/approval/NOC from any Development Authority/Govt. Body/Forest Deptt./and other concerned Deptt. for construction of 33KV line(a) Kuccha Road |
| 226 | 11KV LineThe excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I Clamps size of 65x8mm, 'F' bracket 75x10mm, G.I Nut bolt & washer, V-type X-arm, Pin Insulator, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required.(i) Single Pole(a) 8.5Mtr. PCC Pole (Single Circuit) |
| 227 | (b) 11Mtr. PCC Pole (Single Circuit) |
| 228 | The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I .Clamps size of 75x10mm, 65x8mm, G.I Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 3.5mtr long, from G.I Angle 65x65x6mm. The work includes cutting holes and providing G.I Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.(i) Double Pole Structures(a) 8.5Mtr. PCC Pole |
| 229 | (b) 11Mtr. PCC Pole |
| 230 | (b) 11Mtr. PCC Pole (Riser) |
| 231 | Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. (Civil material provided by firm)(i) Single Pole(a) 11Mtr. PCC Pole (Single Circuit) |
| 232 | (b) 8.5Mtr. PCC Pole (Single Circuit) |
| 233 | (ii) Double Pole Structures(a) 8.5Mtr. PCC Pole (Single Circuit) |
| 234 | (b) 11Mtr. PCC Pole (Single Circuit) |
| 235 | Grouting of stay rods (16x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc. (Civil material provided by firm) |
| 236 | Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps. |
| 237 | Earthing of supports with M.S. earth Rod of (20x2540)mm long including excavation of pit and driving M.S.Rod 3.0M apart from suppor and 0.5M below the ground level and connecting belowl the earth electrodes with the help of G.I.wire No.8SWG and earthing lugs. |
| 238 | Laying, spreading, lifting and final sagging of 3 phases ACSR Weasel/Rabbit conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel. |
| 239 | Making Jumpers on Sectional Pole, by providing & fixing of P.G.Clamps of proper sizes, suitable for Dog Conductor/ 11KV, 3x185Sq.mm XLPE cable (12 Nos. P.G.Clamps at each section double Pole & 06 No. P.G.Clamps at each end double Pole).(a) Double Pole |
| 240 | Guarding between two poles like single poles, double poles, four poles, etc. to guard L.T., 11KV Line telephone line and river crossing, road crossing etc. with M.S.wire No.6SWG, M.S.wire No.8SWG and M.S.wire No.16SWG including cutting with fabrication and fixing of M.S.Guarding angle 75x75x6mm with Providing & fixing M.S.clamps size 75x10mm, M.S.Turn buckle, M.S.Eye bolt, nut bolts & washer etc, as per drawing. |
| 241 | Providing & Fixing of SMC Danger board at each Pole as per specification of the drawing. Size 200mmx250mm & 3mm thickness with G.I.Clamp & nut & bolt for 11KV |
| 242 | Providing & Fixing of SMC Number Plate at each Pole as per specification of the drawing. Size 200mmx250mm & 3mm thickness with G.I.Clamp & nut & bolt. |
| 243 | Making H.T.Connection of the proposed line from 11KV Line. The work consists of fixing & fabrication of Dropper Channels, & fixing of Disc Insulators, Pin Insulators, jumpering with P.G.Clamps, clamping and binding etc,as per site conditions. |
| 244 | Providing & Wrapping of 2.0Kg, barbed wire per pole on 33KV ST Poles SP-55/SP-72/PCC Poles as anti-climbing device for a length of 0.9Mtr. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75Mtr. from the ground, complete with providing and fixing of lower end & upper end clamps made of M.S.Flat 40x5mm complete with nuts & bolts. |
| 245 | Cutting of Tree Branches |
| 246 | Extra Work of T-off supply & Connection new line to existing line. |
| 247 | UG Cable (HDD Method)-For 11 KV LineDigging of Pit by excavation of earth of 1600x1600mm size for 11KV line |
| 248 | Laying of HDPE Pipe PE-100, PN-6, DN-110mm dia by HDD trenchless method, as per site requirement. |
| 249 | Laying of 11KV, 3x185Sq.mm XLPE cable in HDPE Pipe PE-100, PN-6, DN-110mm dia by HDD trenchless method, as per site requirement. |
| 250 | Back filling of excavated earth in the pit upto the ground level and ramming properly. |
| 251 | Safe laying of 11KV, 3x185q.mm. XLPE Cable in Cable Trench to respective Double Pole. |
| 252 | Providing & Laying of Ist Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench and Stone Slab of size 450x600x40mm on top of the Cable, Providing 75mm thickness River sand for cushion beneath and 75mm above the cable as per specification. |
| 253 | Laying of 11KV, 3x185Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing cable trench, Pucca trench, nala x-ing & G.I.Pipe and making connection with 33KV over head line at both ends. |
| 254 | Providing and fixing 150mm dia (Minimum 2mm thick) 2mm thick 3M long G.I.Pipe over 11KV, 3x185Sq.mm XLPE Cable before mounting the 2No. Cable on double pole. Work includes fixing of Clamp, sealing of top and bottom end of the G.I.Pipe. One end of G.I.Pipe is to be buried under earth about 500mm. |
| 255 | Making of 11KV Indoor/Outdoor type cable end termination by heat shrinkable XLPE Cable Jointing Kits and crimping with proper size aluminium lugs. Work includes providing Aluminum lugs, insulating tapes etc as per specifications. |
| 256 | Supply & fixing of cable route marker along the route of 11KV cable with proper grouted with proper painting & marking PVVNL, 11KV Cable. |
| 257 | UG Cable (Open Trench Method)-for 11 KV LineDigging of Trench by excavation of earth of 1050x650mm size for 11 KV line |
| 258 | Laying of 11KV 3×185mm2 Cable & back filling of earth including Supply & Laying of Ist Class bricks work for making chulla and sand work for cushin.and stone slav over the chulla |
| 259 | Safely laying of 11KV 3×185mm² XLPE cable along with spare cable into trench including loop |
| 260 | Safe laying of 11 KV XLPE cable in Air on Double on D/P/Riser |
| 261 | Cost of consultance and lizaaling fee for All type of permission/approval/NOC from Electricity Safety and any Other Authorites (i.e. Development Authority/ Govt. Body/Forest Deptt. and other concerned Deptt.) |
| 262 | Cartage of empty cable drum from site to PVVNL store including loading & unloading at both ends respectively. |
| 263 | Survey charges |
| 264 | Sundries |
| 265 | GI wire 16 SWG |
| 266 | PG Clamp Rabbit to Rabbit |
| 267 | Lug for ACSR Rabbit Conductor |
| 268 | Lug for ACSR Dog Conductor |
| 269 | Extra side bracket 100x50 mm |
| 270 | Extra Angle 65x65x6 mm |
| 271 | Extra cable stand for 33 kv line |
| 272 | Extra T-off fot tapping of New Line to existing Line (100x50x6mm) 1525mm Long |
| 273 | F Clamp for 11 kv Line |
| 274 | 10 inch exhaust fan complete Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select % 0.0 0.0 Zero Only Quoted Rate in Words Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail