| 1 | Detail of Work |
| 2 | Safely cartage of PCC Pole 8.5/9/11 Mtr. Long from ESC, SRE to the site of work including loading unloading at both ends. (Dist. up to 20 KM.) |
| 3 | Providing And fixing of Stone Pad 300x300x75mm |
| 4 | Safe cartage of 25/63/100 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.) |
| 5 | Safe cartage of 11 KV Fuse Set from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.) |
| 6 | Safe cartage of 11 KV TPMO from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.) |
| 7 | Safe cartage of ABC Conductor from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.) |
| 8 | Safe cartage of ACSR Weasel Conductor from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.) |
| 9 | Safe cartage of ACSR Rabbit Conductor from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.) |
| 10 | Fabrication & Erection of double Pole on PCC poles up to 8.5/11 Mtr Long with complete fitting with all accessories complete. |
| 11 | Safe installation of 25/63/100 KVA T/F on the double pole with complete fittings including making connections and commissioning. |
| 12 | Safely Installation of 11 KV Fuse set and connection properly. |
| 13 | Safely Installation of 11 KV TPMO and connection properly. |
| 14 | Laying, lifting, Stringing, sagging jumpring & binding of ACSR Weasel Conductor for 11KV/LT Line including complete. |
| 15 | Laying, lifting, Stringing, sagging jumpring & binding of ACSR Rabbit Conductor for 11KV/LT Line including complete. |
| 16 | Providing and fixing dropper MS Channel 100x50x2028 mm |
| 17 | Providing and fixing of MS Top-Channel 125x65x2240 mm |
| 18 | Providing and fixing of Ms Channel 125x65x1300 |
| 19 | Providing and fixing MS Angle 65x65x6x2028 |
| 20 | Providing and fixing MS Angle 75x75x6x2028mm / 75x75x6mm (T OFF) |
| 21 | Fixing of 11 KV Disc insulator |
| 22 | Fixing of 11 KV Disc Fitting |
| 23 | Fixing of 11 KV Polymeric Pin Insulator 11 KV with pin |
| 24 | Fixing of 11 KV X-arm |
| 25 | Providing and fixing of Danger Board Barbed wire including Jumper |
| 26 | Providing and fixing of LT T-Off with bolt & Nuts. |
| 27 | Providing and fixing of Holding Clamp for Top channel TPMO & Fuse |
| 28 | Providing and fixing Dead & Clamp |
| 29 | Providing and fixing Suspension clamp |
| 30 | Providing and fixing of J-hook |
| 31 | Providing and fixing of I-hook |
| 32 | Providing and fixing of PG Clamp |
| 33 | Providing and fixing of Holding clamp |
| 34 | Providing and fixing of PRC Connector with lead |
| 35 | Providing and fixing of Clamp with nut & Bolts |
| 36 | Providing and fixing LT Fuse Set protection unit for 63 and 100 KVA DT with SMC Box |
| 37 | Fixing of Distribution Box |
| 38 | Erection of single support on PCC Pole up to 8.5/9/11Mtr Long with complete fitting of all accessories of 11 KV/LT as per RESPO specification |
| 39 | Concreting of Pole |
| 40 | Concreting of Stay |
| 41 | Earthing of pole/TF by MS Earthing Road of 20x2500 mm & 6SWG earthwire etc |
| 42 | Fixing of 11 KV stay rods by digging of pits in block of 600X600X300 mm. & with new brick and nozzling of stay wire 7/8 SWG and fitting the same on the pole |
| 43 | Providing and fixing of AI LEG LONG BARREL OFF SIZE (LS) |
| 44 | Providing and fixing of LT INCOMING PANNEL WITH METERING EQUIPEMENT |
| 45 | Laying, lifting, Stringing, proper sagging ABC cable of size 3x50/3x95/3x120 sq.mm. including fixing of all accessories. |
| 46 | Laying of Connecting lead 1x16 sq.mm/LT PVC Cable 3.5x150/3.5/70/LT XLPE Cable 1x400sq.mm Please Enable Macros to View BoQ information |