| 1 | SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Rough excavation not exceeding 1.50mtrs deep and getting out in hard/ dense or any soil, complete all as specified and as directed. |
| 3 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in Hard/Dense soil, complete all as specified and as directed. |
| 4 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed. |
| 5 | Reinforced cement concrete, design mix M-25, type B-1 (using 20mm graded crushed stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.50m span, complete all as specified and as directed. |
| 6 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similar work exceeding 5cm but not exceeding10cm wide, complete all as specified and as directed. |
| 7 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for smooth and fair finishes of flat surfaces, complete all as specified and as directed. |
| 8 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 9 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 10 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, exceeding 10cm in width and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 11 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, 10cm in thickness and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 12 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 13 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 14 | Hardcore of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 15 | Plain cement concrete M-10(1:3:6), type C-2, (using 40mm graded crushed stone aggregate), nominal mix in surface channels and drains, including necessary form work, complete all as specified and as directed. |
| 16 | Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 75mm thick, as in plinth protection, finish even and smooth without using extra cement, complete all as specified and as directed. |
| 17 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), 100mm thick, as in sub base, finish even and smooth without using extra cement, complete all as specified and as directed. |
| 18 | Non-skid, coloured, ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 Per Square Metre but not exceeding 0.18 Per Square Metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 19 | Glazed ceramic coloured tiles in vertical surface/ dado, size 300x200x6/7mm, 300x450x6/7mm, 350x250x6/7mm, or 450x350x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including rendering of 10mm thick in cement mortar 1:4 as backing of tiles, complete all as specified and as directed. |
| 20 | Rolled mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St.-240, complete all as specified and as directed. |
| 21 | Rolled mild steel in, plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290, (Gde E-165), complete all as specified and as directed. |
| 22 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with two Nos. of washers and one hexagonal or square nut, length of bolt exceeding 22.50cm long but not exceeding 30.0cm long and Diameter of neck in 16mm to 20mm, complete all as specified and as directed. |
| 23 | Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed. |
| 24 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing in SSR, complete all as specified and as directed. |
| 25 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 26 | Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 27 | Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 28 | Aluminium anodised, barrel tower bolts of extruded Section, size 125mm long and fixed, complete all as specified and as directed. |
| 29 | Extruded aluminium alloy handles, fabricated type, anodised, size 150mm, complete all as specified and as directed. |
| 30 | Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed. |
| 31 | Factory made steel ventilator, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and and as directed. |
| 32 | Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, preparatory to distempering, complete all as specified and as directed. |
| 33 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paintlime wash, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 34 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paintlime wash, complete all as specified and as directed. Please Enable Macros to View BoQ information |